Cargando…
Tin-filtered 100 kV ultra-low-dose CT of the paranasal sinus: Initial clinical results
OBJECTIVES: To investigate the feasibility, diagnostic image quality and radiation dose of 3(rd) generation dual-source computed tomography (CT) using a tin-filtered 100 kV protocol in patients with suspected acute inflammatory sinus disease. METHODS: We retrospectively evaluated 109 consecutive pat...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6502333/ https://www.ncbi.nlm.nih.gov/pubmed/31059550 http://dx.doi.org/10.1371/journal.pone.0216295 |
_version_ | 1783416245266153472 |
---|---|
author | Petritsch, Bernhard Kosmala, Aleksander Weng, Andreas Max Bley, Thorsten Alexander |
author_facet | Petritsch, Bernhard Kosmala, Aleksander Weng, Andreas Max Bley, Thorsten Alexander |
author_sort | Petritsch, Bernhard |
collection | PubMed |
description | OBJECTIVES: To investigate the feasibility, diagnostic image quality and radiation dose of 3(rd) generation dual-source computed tomography (CT) using a tin-filtered 100 kV protocol in patients with suspected acute inflammatory sinus disease. METHODS: We retrospectively evaluated 109 consecutive patients who underwent CT (Siemens SOMATOM Force, Erlangen, Germany) of the paranasal sinus with a new tin-filtered scan-protocol (Sn100 kV; tube current 35 mAs) using iterative reconstruction. Two readers independently assessed subjective image quality using a five-point Likert scale (1 = excellent, 5 = non-diagnostic). Inter-observer agreement was calculated and expressed as percentage of agreement. Noise was determined for calculation of signal-to-noise-ratio (SNR). Effective radiation dose (ED) was calculated from the dose-length-product (DLP). RESULTS: All examinations showed diagnostic image quality regarding evaluation of inflammatory sinus disease. On average, subjective general image quality was rated moderate (= 3) with a percentage of agreement between the observers of 81%. The mean image noise was 14.3 HU. The calculated median SNR was 6.0 for intraorbital fat, and 3.6 for the vitreous body, respectively. The median DLP was 2.1 mGy*cm, resulting in a median ED of 0.012 mSv. CONCLUSIONS: Taking the study limitations into account, ultra-low-dose tin-filtered CT of the paranasal sinus at a tube voltage of 100 kV utilizing an iterative reconstruction algorithm provides for reliable exclusion of suspected acute inflammatory sinus disease in 100% of the cases. |
format | Online Article Text |
id | pubmed-6502333 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-65023332019-05-23 Tin-filtered 100 kV ultra-low-dose CT of the paranasal sinus: Initial clinical results Petritsch, Bernhard Kosmala, Aleksander Weng, Andreas Max Bley, Thorsten Alexander PLoS One Research Article OBJECTIVES: To investigate the feasibility, diagnostic image quality and radiation dose of 3(rd) generation dual-source computed tomography (CT) using a tin-filtered 100 kV protocol in patients with suspected acute inflammatory sinus disease. METHODS: We retrospectively evaluated 109 consecutive patients who underwent CT (Siemens SOMATOM Force, Erlangen, Germany) of the paranasal sinus with a new tin-filtered scan-protocol (Sn100 kV; tube current 35 mAs) using iterative reconstruction. Two readers independently assessed subjective image quality using a five-point Likert scale (1 = excellent, 5 = non-diagnostic). Inter-observer agreement was calculated and expressed as percentage of agreement. Noise was determined for calculation of signal-to-noise-ratio (SNR). Effective radiation dose (ED) was calculated from the dose-length-product (DLP). RESULTS: All examinations showed diagnostic image quality regarding evaluation of inflammatory sinus disease. On average, subjective general image quality was rated moderate (= 3) with a percentage of agreement between the observers of 81%. The mean image noise was 14.3 HU. The calculated median SNR was 6.0 for intraorbital fat, and 3.6 for the vitreous body, respectively. The median DLP was 2.1 mGy*cm, resulting in a median ED of 0.012 mSv. CONCLUSIONS: Taking the study limitations into account, ultra-low-dose tin-filtered CT of the paranasal sinus at a tube voltage of 100 kV utilizing an iterative reconstruction algorithm provides for reliable exclusion of suspected acute inflammatory sinus disease in 100% of the cases. Public Library of Science 2019-05-06 /pmc/articles/PMC6502333/ /pubmed/31059550 http://dx.doi.org/10.1371/journal.pone.0216295 Text en © 2019 Petritsch et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Petritsch, Bernhard Kosmala, Aleksander Weng, Andreas Max Bley, Thorsten Alexander Tin-filtered 100 kV ultra-low-dose CT of the paranasal sinus: Initial clinical results |
title | Tin-filtered 100 kV ultra-low-dose CT of the paranasal sinus: Initial clinical results |
title_full | Tin-filtered 100 kV ultra-low-dose CT of the paranasal sinus: Initial clinical results |
title_fullStr | Tin-filtered 100 kV ultra-low-dose CT of the paranasal sinus: Initial clinical results |
title_full_unstemmed | Tin-filtered 100 kV ultra-low-dose CT of the paranasal sinus: Initial clinical results |
title_short | Tin-filtered 100 kV ultra-low-dose CT of the paranasal sinus: Initial clinical results |
title_sort | tin-filtered 100 kv ultra-low-dose ct of the paranasal sinus: initial clinical results |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6502333/ https://www.ncbi.nlm.nih.gov/pubmed/31059550 http://dx.doi.org/10.1371/journal.pone.0216295 |
work_keys_str_mv | AT petritschbernhard tinfiltered100kvultralowdosectoftheparanasalsinusinitialclinicalresults AT kosmalaaleksander tinfiltered100kvultralowdosectoftheparanasalsinusinitialclinicalresults AT wengandreasmax tinfiltered100kvultralowdosectoftheparanasalsinusinitialclinicalresults AT bleythorstenalexander tinfiltered100kvultralowdosectoftheparanasalsinusinitialclinicalresults |