Cargando…
Are critical size bone notch defects possible in the rabbit mandible?
OBJECTIVES: Small animal maxillofacial models, such as non-segmental critical size defects (CSDs) in the rabbit mandible, need to be standardized for use as preclinical models of bone regeneration to mimic clinical conditions such as maxillofacial trauma. The objective of this study is the establish...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Association of Oral and Maxillofacial Surgeons
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6502752/ https://www.ncbi.nlm.nih.gov/pubmed/31106138 http://dx.doi.org/10.5125/jkaoms.2019.45.2.97 |
_version_ | 1783416279762206720 |
---|---|
author | Carlisle, Patricia L. Guda, Teja Silliman, David T. Hale, Robert G. Brown Baer, Pamela R. |
author_facet | Carlisle, Patricia L. Guda, Teja Silliman, David T. Hale, Robert G. Brown Baer, Pamela R. |
author_sort | Carlisle, Patricia L. |
collection | PubMed |
description | OBJECTIVES: Small animal maxillofacial models, such as non-segmental critical size defects (CSDs) in the rabbit mandible, need to be standardized for use as preclinical models of bone regeneration to mimic clinical conditions such as maxillofacial trauma. The objective of this study is the establishment of a mechanically competent CSD model in the rabbit mandible to allow standardized evaluation of bone regeneration therapies. MATERIALS AND METHODS: Three sizes of bony defect were generated in the mandibular body of rabbit hemi-mandibles: 12 mm×5 mm, 12 mm×8 mm, and 15 mm×10 mm. The hemi-mandibles were tested to failure in 3-point flexure. The 12 mm×5 mm defect was then chosen for the defect size created in the mandibles of 26 rabbits with or without cautery of the defect margins and bone regeneration was assessed after 6 and 12 weeks. Regenerated bone density and volume were evaluated using radiography, micro-computed tomography, and histology. RESULTS: Flexural strength of the 12 mm×5 mm defect was similar to its contralateral; whereas the 12 mm×8 mm and 15 mm×10 mm groups carried significantly less load than their respective contralaterals (P<0.05). This demonstrated that the 12 mm×5 mm defect did not significantly compromise mandibular mechanical integrity. Significantly less (P<0.05) bone was regenerated at 6 weeks in cauterized defect margins compared to controls without cautery. After 12 weeks, the bone volume of the group with cautery increased to that of the control without cautery after 6 weeks. CONCLUSION: An empty defect size of 12 mm×5 mm in the rabbit mandibular model maintains sufficient mechanical stability to not require additional stabilization. However, this defect size allows for bone regeneration across the defect. Cautery of the defect only delays regeneration by 6 weeks suggesting that the performance of bone graft materials in mandibular defects of this size should be considered with caution. |
format | Online Article Text |
id | pubmed-6502752 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | The Korean Association of Oral and Maxillofacial Surgeons |
record_format | MEDLINE/PubMed |
spelling | pubmed-65027522019-05-17 Are critical size bone notch defects possible in the rabbit mandible? Carlisle, Patricia L. Guda, Teja Silliman, David T. Hale, Robert G. Brown Baer, Pamela R. J Korean Assoc Oral Maxillofac Surg Original Article OBJECTIVES: Small animal maxillofacial models, such as non-segmental critical size defects (CSDs) in the rabbit mandible, need to be standardized for use as preclinical models of bone regeneration to mimic clinical conditions such as maxillofacial trauma. The objective of this study is the establishment of a mechanically competent CSD model in the rabbit mandible to allow standardized evaluation of bone regeneration therapies. MATERIALS AND METHODS: Three sizes of bony defect were generated in the mandibular body of rabbit hemi-mandibles: 12 mm×5 mm, 12 mm×8 mm, and 15 mm×10 mm. The hemi-mandibles were tested to failure in 3-point flexure. The 12 mm×5 mm defect was then chosen for the defect size created in the mandibles of 26 rabbits with or without cautery of the defect margins and bone regeneration was assessed after 6 and 12 weeks. Regenerated bone density and volume were evaluated using radiography, micro-computed tomography, and histology. RESULTS: Flexural strength of the 12 mm×5 mm defect was similar to its contralateral; whereas the 12 mm×8 mm and 15 mm×10 mm groups carried significantly less load than their respective contralaterals (P<0.05). This demonstrated that the 12 mm×5 mm defect did not significantly compromise mandibular mechanical integrity. Significantly less (P<0.05) bone was regenerated at 6 weeks in cauterized defect margins compared to controls without cautery. After 12 weeks, the bone volume of the group with cautery increased to that of the control without cautery after 6 weeks. CONCLUSION: An empty defect size of 12 mm×5 mm in the rabbit mandibular model maintains sufficient mechanical stability to not require additional stabilization. However, this defect size allows for bone regeneration across the defect. Cautery of the defect only delays regeneration by 6 weeks suggesting that the performance of bone graft materials in mandibular defects of this size should be considered with caution. The Korean Association of Oral and Maxillofacial Surgeons 2019-04 2019-04-29 /pmc/articles/PMC6502752/ /pubmed/31106138 http://dx.doi.org/10.5125/jkaoms.2019.45.2.97 Text en Copyright © 2019 The Korean Association of Oral and Maxillofacial Surgeons. http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Carlisle, Patricia L. Guda, Teja Silliman, David T. Hale, Robert G. Brown Baer, Pamela R. Are critical size bone notch defects possible in the rabbit mandible? |
title | Are critical size bone notch defects possible in the rabbit mandible? |
title_full | Are critical size bone notch defects possible in the rabbit mandible? |
title_fullStr | Are critical size bone notch defects possible in the rabbit mandible? |
title_full_unstemmed | Are critical size bone notch defects possible in the rabbit mandible? |
title_short | Are critical size bone notch defects possible in the rabbit mandible? |
title_sort | are critical size bone notch defects possible in the rabbit mandible? |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6502752/ https://www.ncbi.nlm.nih.gov/pubmed/31106138 http://dx.doi.org/10.5125/jkaoms.2019.45.2.97 |
work_keys_str_mv | AT carlislepatricial arecriticalsizebonenotchdefectspossibleintherabbitmandible AT gudateja arecriticalsizebonenotchdefectspossibleintherabbitmandible AT sillimandavidt arecriticalsizebonenotchdefectspossibleintherabbitmandible AT halerobertg arecriticalsizebonenotchdefectspossibleintherabbitmandible AT brownbaerpamelar arecriticalsizebonenotchdefectspossibleintherabbitmandible |