Cargando…

Use of Liquid Chromatography-Tandem Mass Spectrometry for Clinical Testing in Korean Laboratories: a Questionnaire Survey

BACKGROUND: The use of liquid chromatography-tandem mass spectrometry (LC-MS/MS) has substantially increased in clinical laboratories worldwide. To assess the status of clinical LC-MS/MS testing in Korean laboratories, a questionnaire survey was performed by the Clinical Mass Spectrometry Research C...

Descripción completa

Detalles Bibliográficos
Autores principales: Chae, Hyojin, Cho, Sung-Eun, Park, Hyung-Doo, Chun, Sail, Lee, Yong-Wha, Yun, Yeo-Min, Song, Sang-Hoon, Lee, Sang-Guk, Lee, Kyunghoon, Song, Junghan, Lee, Soo-Youn
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Laboratory Medicine 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6502944/
https://www.ncbi.nlm.nih.gov/pubmed/31037863
http://dx.doi.org/10.3343/alm.2019.39.5.447
_version_ 1783416317929324544
author Chae, Hyojin
Cho, Sung-Eun
Park, Hyung-Doo
Chun, Sail
Lee, Yong-Wha
Yun, Yeo-Min
Song, Sang-Hoon
Lee, Sang-Guk
Lee, Kyunghoon
Song, Junghan
Lee, Soo-Youn
author_facet Chae, Hyojin
Cho, Sung-Eun
Park, Hyung-Doo
Chun, Sail
Lee, Yong-Wha
Yun, Yeo-Min
Song, Sang-Hoon
Lee, Sang-Guk
Lee, Kyunghoon
Song, Junghan
Lee, Soo-Youn
author_sort Chae, Hyojin
collection PubMed
description BACKGROUND: The use of liquid chromatography-tandem mass spectrometry (LC-MS/MS) has substantially increased in clinical laboratories worldwide. To assess the status of clinical LC-MS/MS testing in Korean laboratories, a questionnaire survey was performed by the Clinical Mass Spectrometry Research Committee of the Korean Society of Clinical Chemistry. METHODS: The questionnaire was distributed to 19 clinical laboratories performing clinical LC-MS/MS from April to May 2018. It asked about general characteristics of the laboratory and commonly utilized clinical LC-MS/MS tests: newborn screening, tacrolimus test, vitamin D test, and plasma metanephrine test. Frequency analysis and other statistical analyses were performed. RESULTS: A total of 17 laboratories responded. The median number of LC-MS/MS instruments, laboratory medicine physicians, and technicians in each laboratory was three, one, and two, respectively. Nine laboratory directors had >10 years of experience with clinical LC-MS/MS. For each LC-MS/MS test, at least two concentrations of QC materials were measured every 24 hours during clinical testing, and all laboratories used QC acceptability criteria based on their established QC means and SDs. All laboratories participated in an external quality assessment program. However, there was inter-laboratory variability in sample preparation methods, instruments, reagents, internal standards, and calibrators. CONCLUSIONS: LC-MS/MS has been successfully introduced in Korean clinical laboratories and is used within a quality framework. Further efforts for harmonization on a nationwide basis could facilitate the widespread use of LC-MS/MS.
format Online
Article
Text
id pubmed-6502944
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Society for Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-65029442019-09-01 Use of Liquid Chromatography-Tandem Mass Spectrometry for Clinical Testing in Korean Laboratories: a Questionnaire Survey Chae, Hyojin Cho, Sung-Eun Park, Hyung-Doo Chun, Sail Lee, Yong-Wha Yun, Yeo-Min Song, Sang-Hoon Lee, Sang-Guk Lee, Kyunghoon Song, Junghan Lee, Soo-Youn Ann Lab Med Original Article BACKGROUND: The use of liquid chromatography-tandem mass spectrometry (LC-MS/MS) has substantially increased in clinical laboratories worldwide. To assess the status of clinical LC-MS/MS testing in Korean laboratories, a questionnaire survey was performed by the Clinical Mass Spectrometry Research Committee of the Korean Society of Clinical Chemistry. METHODS: The questionnaire was distributed to 19 clinical laboratories performing clinical LC-MS/MS from April to May 2018. It asked about general characteristics of the laboratory and commonly utilized clinical LC-MS/MS tests: newborn screening, tacrolimus test, vitamin D test, and plasma metanephrine test. Frequency analysis and other statistical analyses were performed. RESULTS: A total of 17 laboratories responded. The median number of LC-MS/MS instruments, laboratory medicine physicians, and technicians in each laboratory was three, one, and two, respectively. Nine laboratory directors had >10 years of experience with clinical LC-MS/MS. For each LC-MS/MS test, at least two concentrations of QC materials were measured every 24 hours during clinical testing, and all laboratories used QC acceptability criteria based on their established QC means and SDs. All laboratories participated in an external quality assessment program. However, there was inter-laboratory variability in sample preparation methods, instruments, reagents, internal standards, and calibrators. CONCLUSIONS: LC-MS/MS has been successfully introduced in Korean clinical laboratories and is used within a quality framework. Further efforts for harmonization on a nationwide basis could facilitate the widespread use of LC-MS/MS. The Korean Society for Laboratory Medicine 2019-09 2019-04-26 /pmc/articles/PMC6502944/ /pubmed/31037863 http://dx.doi.org/10.3343/alm.2019.39.5.447 Text en © The Korean Society for Laboratory Medicine http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Chae, Hyojin
Cho, Sung-Eun
Park, Hyung-Doo
Chun, Sail
Lee, Yong-Wha
Yun, Yeo-Min
Song, Sang-Hoon
Lee, Sang-Guk
Lee, Kyunghoon
Song, Junghan
Lee, Soo-Youn
Use of Liquid Chromatography-Tandem Mass Spectrometry for Clinical Testing in Korean Laboratories: a Questionnaire Survey
title Use of Liquid Chromatography-Tandem Mass Spectrometry for Clinical Testing in Korean Laboratories: a Questionnaire Survey
title_full Use of Liquid Chromatography-Tandem Mass Spectrometry for Clinical Testing in Korean Laboratories: a Questionnaire Survey
title_fullStr Use of Liquid Chromatography-Tandem Mass Spectrometry for Clinical Testing in Korean Laboratories: a Questionnaire Survey
title_full_unstemmed Use of Liquid Chromatography-Tandem Mass Spectrometry for Clinical Testing in Korean Laboratories: a Questionnaire Survey
title_short Use of Liquid Chromatography-Tandem Mass Spectrometry for Clinical Testing in Korean Laboratories: a Questionnaire Survey
title_sort use of liquid chromatography-tandem mass spectrometry for clinical testing in korean laboratories: a questionnaire survey
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6502944/
https://www.ncbi.nlm.nih.gov/pubmed/31037863
http://dx.doi.org/10.3343/alm.2019.39.5.447
work_keys_str_mv AT chaehyojin useofliquidchromatographytandemmassspectrometryforclinicaltestinginkoreanlaboratoriesaquestionnairesurvey
AT chosungeun useofliquidchromatographytandemmassspectrometryforclinicaltestinginkoreanlaboratoriesaquestionnairesurvey
AT parkhyungdoo useofliquidchromatographytandemmassspectrometryforclinicaltestinginkoreanlaboratoriesaquestionnairesurvey
AT chunsail useofliquidchromatographytandemmassspectrometryforclinicaltestinginkoreanlaboratoriesaquestionnairesurvey
AT leeyongwha useofliquidchromatographytandemmassspectrometryforclinicaltestinginkoreanlaboratoriesaquestionnairesurvey
AT yunyeomin useofliquidchromatographytandemmassspectrometryforclinicaltestinginkoreanlaboratoriesaquestionnairesurvey
AT songsanghoon useofliquidchromatographytandemmassspectrometryforclinicaltestinginkoreanlaboratoriesaquestionnairesurvey
AT leesangguk useofliquidchromatographytandemmassspectrometryforclinicaltestinginkoreanlaboratoriesaquestionnairesurvey
AT leekyunghoon useofliquidchromatographytandemmassspectrometryforclinicaltestinginkoreanlaboratoriesaquestionnairesurvey
AT songjunghan useofliquidchromatographytandemmassspectrometryforclinicaltestinginkoreanlaboratoriesaquestionnairesurvey
AT leesooyoun useofliquidchromatographytandemmassspectrometryforclinicaltestinginkoreanlaboratoriesaquestionnairesurvey
AT useofliquidchromatographytandemmassspectrometryforclinicaltestinginkoreanlaboratoriesaquestionnairesurvey