Cargando…

Comparison of cobas EGFR Mutation Test v2 and PANAMutyper-R-EGFR for Detection and Semi-Quantification of Epidermal Growth Factor Receptor Mutations in Plasma and Pleural Effusion Supernatant

BACKGROUND: Plasma epidermal growth factor receptor (EGFR) mutation tests are less invasive than tissue EGFR mutation tests. We determined which of two kits is more efficient: cobas EGFR Mutation test v2 (cobasv2; Roche Molecular Systems, Pleasanton, CA, USA) or PANAMutyper-R-EGFR (Mutyper; Panagene...

Descripción completa

Detalles Bibliográficos
Autores principales: Han, A-Lum, Kim, Hak-Ryul, Choi, Keum-Ha, Hwang, Ki-Eun, Zhu, Mengyu, Huang, Yuya, Wu, Moxin, Lee, Young-Jin, Park, Min-Cheol, Cho, Ji-Hyun, Park, Do-Sim
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Laboratory Medicine 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6502955/
https://www.ncbi.nlm.nih.gov/pubmed/31037867
http://dx.doi.org/10.3343/alm.2019.39.5.478
_version_ 1783416320492044288
author Han, A-Lum
Kim, Hak-Ryul
Choi, Keum-Ha
Hwang, Ki-Eun
Zhu, Mengyu
Huang, Yuya
Wu, Moxin
Lee, Young-Jin
Park, Min-Cheol
Cho, Ji-Hyun
Park, Do-Sim
author_facet Han, A-Lum
Kim, Hak-Ryul
Choi, Keum-Ha
Hwang, Ki-Eun
Zhu, Mengyu
Huang, Yuya
Wu, Moxin
Lee, Young-Jin
Park, Min-Cheol
Cho, Ji-Hyun
Park, Do-Sim
author_sort Han, A-Lum
collection PubMed
description BACKGROUND: Plasma epidermal growth factor receptor (EGFR) mutation tests are less invasive than tissue EGFR mutation tests. We determined which of two kits is more efficient: cobas EGFR Mutation test v2 (cobasv2; Roche Molecular Systems, Pleasanton, CA, USA) or PANAMutyper-R-EGFR (Mutyper; Panagene, Daejeon, Korea). We also evaluated whether pleural effusion supernatant (PE-SUP) samples are assayable, similar to plasma samples, using these two kits. METHODS: We analyzed 156 plasma and PE-SUP samples (31 paired samples) from 116 individuals. We compared the kits in terms of accuracy, assessed genotype concordance (weighted κ with 95% confidence intervals), and calculated Spearman's rho between semi-quantitatively measured EGFR-mutant levels (SQIs) measured by each kit. We also compared sensitivity using 47 EGFR-mutant harboring samples divided into more-dilute and less-dilute samples (dilution ratio: ≥ or <1:1,000). RESULTS: cobasv2 tended to have higher accuracy than Mutyper (73% vs 69%, P=0.53), and PE-SUP samples had significantly higher accuracy than plasma samples (97% vs 55–71%) for both kits. Genotype concordance was 98% (κ=0.92, 0.88–0.96). SQIs showed strong positive correlations (P<0.0001). In less-dilute samples, accuracy and sensitivity did not differ significantly between kits. In more-dilute samples, cobasv2 tended to have higher sensitivity than Mutyper (43% vs 20%, P=0.07). CONCLUSIONS: The kits have similar performance in terms of EGFR mutation detection and semi-quantification in plasma and PE-SUP samples. cobasv2 tends to outperform Mutyper in detecting less-abundant EGFR-mutants. PE-SUP samples are assayable using either kit.
format Online
Article
Text
id pubmed-6502955
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Society for Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-65029552019-09-01 Comparison of cobas EGFR Mutation Test v2 and PANAMutyper-R-EGFR for Detection and Semi-Quantification of Epidermal Growth Factor Receptor Mutations in Plasma and Pleural Effusion Supernatant Han, A-Lum Kim, Hak-Ryul Choi, Keum-Ha Hwang, Ki-Eun Zhu, Mengyu Huang, Yuya Wu, Moxin Lee, Young-Jin Park, Min-Cheol Cho, Ji-Hyun Park, Do-Sim Ann Lab Med Original Article BACKGROUND: Plasma epidermal growth factor receptor (EGFR) mutation tests are less invasive than tissue EGFR mutation tests. We determined which of two kits is more efficient: cobas EGFR Mutation test v2 (cobasv2; Roche Molecular Systems, Pleasanton, CA, USA) or PANAMutyper-R-EGFR (Mutyper; Panagene, Daejeon, Korea). We also evaluated whether pleural effusion supernatant (PE-SUP) samples are assayable, similar to plasma samples, using these two kits. METHODS: We analyzed 156 plasma and PE-SUP samples (31 paired samples) from 116 individuals. We compared the kits in terms of accuracy, assessed genotype concordance (weighted κ with 95% confidence intervals), and calculated Spearman's rho between semi-quantitatively measured EGFR-mutant levels (SQIs) measured by each kit. We also compared sensitivity using 47 EGFR-mutant harboring samples divided into more-dilute and less-dilute samples (dilution ratio: ≥ or <1:1,000). RESULTS: cobasv2 tended to have higher accuracy than Mutyper (73% vs 69%, P=0.53), and PE-SUP samples had significantly higher accuracy than plasma samples (97% vs 55–71%) for both kits. Genotype concordance was 98% (κ=0.92, 0.88–0.96). SQIs showed strong positive correlations (P<0.0001). In less-dilute samples, accuracy and sensitivity did not differ significantly between kits. In more-dilute samples, cobasv2 tended to have higher sensitivity than Mutyper (43% vs 20%, P=0.07). CONCLUSIONS: The kits have similar performance in terms of EGFR mutation detection and semi-quantification in plasma and PE-SUP samples. cobasv2 tends to outperform Mutyper in detecting less-abundant EGFR-mutants. PE-SUP samples are assayable using either kit. The Korean Society for Laboratory Medicine 2019-09 2019-04-26 /pmc/articles/PMC6502955/ /pubmed/31037867 http://dx.doi.org/10.3343/alm.2019.39.5.478 Text en © The Korean Society for Laboratory Medicine http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Han, A-Lum
Kim, Hak-Ryul
Choi, Keum-Ha
Hwang, Ki-Eun
Zhu, Mengyu
Huang, Yuya
Wu, Moxin
Lee, Young-Jin
Park, Min-Cheol
Cho, Ji-Hyun
Park, Do-Sim
Comparison of cobas EGFR Mutation Test v2 and PANAMutyper-R-EGFR for Detection and Semi-Quantification of Epidermal Growth Factor Receptor Mutations in Plasma and Pleural Effusion Supernatant
title Comparison of cobas EGFR Mutation Test v2 and PANAMutyper-R-EGFR for Detection and Semi-Quantification of Epidermal Growth Factor Receptor Mutations in Plasma and Pleural Effusion Supernatant
title_full Comparison of cobas EGFR Mutation Test v2 and PANAMutyper-R-EGFR for Detection and Semi-Quantification of Epidermal Growth Factor Receptor Mutations in Plasma and Pleural Effusion Supernatant
title_fullStr Comparison of cobas EGFR Mutation Test v2 and PANAMutyper-R-EGFR for Detection and Semi-Quantification of Epidermal Growth Factor Receptor Mutations in Plasma and Pleural Effusion Supernatant
title_full_unstemmed Comparison of cobas EGFR Mutation Test v2 and PANAMutyper-R-EGFR for Detection and Semi-Quantification of Epidermal Growth Factor Receptor Mutations in Plasma and Pleural Effusion Supernatant
title_short Comparison of cobas EGFR Mutation Test v2 and PANAMutyper-R-EGFR for Detection and Semi-Quantification of Epidermal Growth Factor Receptor Mutations in Plasma and Pleural Effusion Supernatant
title_sort comparison of cobas egfr mutation test v2 and panamutyper-r-egfr for detection and semi-quantification of epidermal growth factor receptor mutations in plasma and pleural effusion supernatant
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6502955/
https://www.ncbi.nlm.nih.gov/pubmed/31037867
http://dx.doi.org/10.3343/alm.2019.39.5.478
work_keys_str_mv AT hanalum comparisonofcobasegfrmutationtestv2andpanamutyperregfrfordetectionandsemiquantificationofepidermalgrowthfactorreceptormutationsinplasmaandpleuraleffusionsupernatant
AT kimhakryul comparisonofcobasegfrmutationtestv2andpanamutyperregfrfordetectionandsemiquantificationofepidermalgrowthfactorreceptormutationsinplasmaandpleuraleffusionsupernatant
AT choikeumha comparisonofcobasegfrmutationtestv2andpanamutyperregfrfordetectionandsemiquantificationofepidermalgrowthfactorreceptormutationsinplasmaandpleuraleffusionsupernatant
AT hwangkieun comparisonofcobasegfrmutationtestv2andpanamutyperregfrfordetectionandsemiquantificationofepidermalgrowthfactorreceptormutationsinplasmaandpleuraleffusionsupernatant
AT zhumengyu comparisonofcobasegfrmutationtestv2andpanamutyperregfrfordetectionandsemiquantificationofepidermalgrowthfactorreceptormutationsinplasmaandpleuraleffusionsupernatant
AT huangyuya comparisonofcobasegfrmutationtestv2andpanamutyperregfrfordetectionandsemiquantificationofepidermalgrowthfactorreceptormutationsinplasmaandpleuraleffusionsupernatant
AT wumoxin comparisonofcobasegfrmutationtestv2andpanamutyperregfrfordetectionandsemiquantificationofepidermalgrowthfactorreceptormutationsinplasmaandpleuraleffusionsupernatant
AT leeyoungjin comparisonofcobasegfrmutationtestv2andpanamutyperregfrfordetectionandsemiquantificationofepidermalgrowthfactorreceptormutationsinplasmaandpleuraleffusionsupernatant
AT parkmincheol comparisonofcobasegfrmutationtestv2andpanamutyperregfrfordetectionandsemiquantificationofepidermalgrowthfactorreceptormutationsinplasmaandpleuraleffusionsupernatant
AT chojihyun comparisonofcobasegfrmutationtestv2andpanamutyperregfrfordetectionandsemiquantificationofepidermalgrowthfactorreceptormutationsinplasmaandpleuraleffusionsupernatant
AT parkdosim comparisonofcobasegfrmutationtestv2andpanamutyperregfrfordetectionandsemiquantificationofepidermalgrowthfactorreceptormutationsinplasmaandpleuraleffusionsupernatant