Cargando…

Superficial femoral artery stenting via radial access using R2P® Misago® stents: First-in-human report of the new R2P® system

A 73-year-old male with left critical limb ischemia was scheduled to undergo below-the-knee amputation. Prior to the amputation, he was referred to our institute for endovascular treatment. We inserted the new 7-Fr 150-cm-long guiding catheter, SlenGuide(®), into the external iliac artery from the r...

Descripción completa

Detalles Bibliográficos
Autores principales: Shinozaki, Norihiko, Ikari, Yuji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6503586/
https://www.ncbi.nlm.nih.gov/pubmed/31105950
http://dx.doi.org/10.1177/2050313X19847348
_version_ 1783416434012979200
author Shinozaki, Norihiko
Ikari, Yuji
author_facet Shinozaki, Norihiko
Ikari, Yuji
author_sort Shinozaki, Norihiko
collection PubMed
description A 73-year-old male with left critical limb ischemia was scheduled to undergo below-the-knee amputation. Prior to the amputation, he was referred to our institute for endovascular treatment. We inserted the new 7-Fr 150-cm-long guiding catheter, SlenGuide(®), into the external iliac artery from the right radial artery with the 7-Fr Glidesheath Slender(®). We implanted two R2P(®) Misago(®) stents with rapid-exchange, 200-cm-long shaft system in the stenosis of the left superficial femoral artery. This new stent system involves rapid-exchange and a long shaft system; furthermore, it is useful in transradial stenting in the superficial femoral artery.
format Online
Article
Text
id pubmed-6503586
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-65035862019-05-17 Superficial femoral artery stenting via radial access using R2P® Misago® stents: First-in-human report of the new R2P® system Shinozaki, Norihiko Ikari, Yuji SAGE Open Med Case Rep Case Report A 73-year-old male with left critical limb ischemia was scheduled to undergo below-the-knee amputation. Prior to the amputation, he was referred to our institute for endovascular treatment. We inserted the new 7-Fr 150-cm-long guiding catheter, SlenGuide(®), into the external iliac artery from the right radial artery with the 7-Fr Glidesheath Slender(®). We implanted two R2P(®) Misago(®) stents with rapid-exchange, 200-cm-long shaft system in the stenosis of the left superficial femoral artery. This new stent system involves rapid-exchange and a long shaft system; furthermore, it is useful in transradial stenting in the superficial femoral artery. SAGE Publications 2019-05-06 /pmc/articles/PMC6503586/ /pubmed/31105950 http://dx.doi.org/10.1177/2050313X19847348 Text en © The Author(s) 2019 http://www.creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Case Report
Shinozaki, Norihiko
Ikari, Yuji
Superficial femoral artery stenting via radial access using R2P® Misago® stents: First-in-human report of the new R2P® system
title Superficial femoral artery stenting via radial access using R2P® Misago® stents: First-in-human report of the new R2P® system
title_full Superficial femoral artery stenting via radial access using R2P® Misago® stents: First-in-human report of the new R2P® system
title_fullStr Superficial femoral artery stenting via radial access using R2P® Misago® stents: First-in-human report of the new R2P® system
title_full_unstemmed Superficial femoral artery stenting via radial access using R2P® Misago® stents: First-in-human report of the new R2P® system
title_short Superficial femoral artery stenting via radial access using R2P® Misago® stents: First-in-human report of the new R2P® system
title_sort superficial femoral artery stenting via radial access using r2p® misago® stents: first-in-human report of the new r2p® system
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6503586/
https://www.ncbi.nlm.nih.gov/pubmed/31105950
http://dx.doi.org/10.1177/2050313X19847348
work_keys_str_mv AT shinozakinorihiko superficialfemoralarterystentingviaradialaccessusingr2pmisagostentsfirstinhumanreportofthenewr2psystem
AT ikariyuji superficialfemoralarterystentingviaradialaccessusingr2pmisagostentsfirstinhumanreportofthenewr2psystem