Cargando…
Test-retest reliability and minimal detectable change of the Cognitive Abilities Screening Instrument in patients with dementia
BACKGROUND: The Cognitive Abilities Screening Instrument (CASI) is widely used to assess global cognitive function in patients with dementia. It contains nine cognitive domains, namely long-term memory, short-term memory, attention, mental manipulation, orientation, abstraction and judgment, languag...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6504091/ https://www.ncbi.nlm.nih.gov/pubmed/31063491 http://dx.doi.org/10.1371/journal.pone.0216450 |
_version_ | 1783416511436685312 |
---|---|
author | Chiu, En-Chi Yip, Ping-Keung Woo, Peter Lin, Yi-Te |
author_facet | Chiu, En-Chi Yip, Ping-Keung Woo, Peter Lin, Yi-Te |
author_sort | Chiu, En-Chi |
collection | PubMed |
description | BACKGROUND: The Cognitive Abilities Screening Instrument (CASI) is widely used to assess global cognitive function in patients with dementia. It contains nine cognitive domains, namely long-term memory, short-term memory, attention, mental manipulation, orientation, abstraction and judgment, language, visual construction, and list-generating fluency. However, test-retest reliability and minimal detectable change (MDC) of the CASI are largely unknown in patients with dementia, which limits its utility and the explanation of a score change. PURPOSE: The purpose of this study was to examine test-retest reliability and calculate MDC of the CASI in patients with dementia. METHODS: Fifty-two patients with dementia completed the CASI twice with a two-week interval. The frequencies of the scores in the Clinical Dementia Rating (0.5, 1, and ≥ 2) were 38.5, 36.5, and 25.0, respectively. Test-retest reliability was examined using intraclass correlation coefficient (ICC) for the total score and nine domains of the CASI. The MDC was calculated based on standard error of measurement. RESULTS: The ICC value of the CASI total score was 0.97 while the ICC value for the nine domains were 0.65–0.92. The MDC values (MDC%) were 11.6 (12.9%), 2.8 (23.2%), 4.5 (41.2%), 3.4 (42.1%), 4.9 (49.2%), 5.3 (29.2%), 3.4 (28.8%), 2.2 (22.3%), 3.2 (32.1%), and 3.1 (30.7%) for CASI total score, long-term memory, short-term memory, attention, mental manipulation, orientation, abstraction and judgment, language, visual construction, and list-generating fluency, respectively. CONCLUSION: Our results revealed that the CASI has sufficient test-retest reliability. The MDC values are useful in determining a real change (i.e., improvement or deterioration) between two assessments of an individual patient. However, four domains (i.e., short-term memory, attention, mental manipulation, and list-generating fluency) demonstrated lower ICC values and substantial random measurement errors. Clinicians and researchers should be cautious while using these four domains to explain score changes between repeated assessments of patients with dementia. |
format | Online Article Text |
id | pubmed-6504091 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-65040912019-05-09 Test-retest reliability and minimal detectable change of the Cognitive Abilities Screening Instrument in patients with dementia Chiu, En-Chi Yip, Ping-Keung Woo, Peter Lin, Yi-Te PLoS One Research Article BACKGROUND: The Cognitive Abilities Screening Instrument (CASI) is widely used to assess global cognitive function in patients with dementia. It contains nine cognitive domains, namely long-term memory, short-term memory, attention, mental manipulation, orientation, abstraction and judgment, language, visual construction, and list-generating fluency. However, test-retest reliability and minimal detectable change (MDC) of the CASI are largely unknown in patients with dementia, which limits its utility and the explanation of a score change. PURPOSE: The purpose of this study was to examine test-retest reliability and calculate MDC of the CASI in patients with dementia. METHODS: Fifty-two patients with dementia completed the CASI twice with a two-week interval. The frequencies of the scores in the Clinical Dementia Rating (0.5, 1, and ≥ 2) were 38.5, 36.5, and 25.0, respectively. Test-retest reliability was examined using intraclass correlation coefficient (ICC) for the total score and nine domains of the CASI. The MDC was calculated based on standard error of measurement. RESULTS: The ICC value of the CASI total score was 0.97 while the ICC value for the nine domains were 0.65–0.92. The MDC values (MDC%) were 11.6 (12.9%), 2.8 (23.2%), 4.5 (41.2%), 3.4 (42.1%), 4.9 (49.2%), 5.3 (29.2%), 3.4 (28.8%), 2.2 (22.3%), 3.2 (32.1%), and 3.1 (30.7%) for CASI total score, long-term memory, short-term memory, attention, mental manipulation, orientation, abstraction and judgment, language, visual construction, and list-generating fluency, respectively. CONCLUSION: Our results revealed that the CASI has sufficient test-retest reliability. The MDC values are useful in determining a real change (i.e., improvement or deterioration) between two assessments of an individual patient. However, four domains (i.e., short-term memory, attention, mental manipulation, and list-generating fluency) demonstrated lower ICC values and substantial random measurement errors. Clinicians and researchers should be cautious while using these four domains to explain score changes between repeated assessments of patients with dementia. Public Library of Science 2019-05-07 /pmc/articles/PMC6504091/ /pubmed/31063491 http://dx.doi.org/10.1371/journal.pone.0216450 Text en © 2019 Chiu et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Chiu, En-Chi Yip, Ping-Keung Woo, Peter Lin, Yi-Te Test-retest reliability and minimal detectable change of the Cognitive Abilities Screening Instrument in patients with dementia |
title | Test-retest reliability and minimal detectable change of the Cognitive Abilities Screening Instrument in patients with dementia |
title_full | Test-retest reliability and minimal detectable change of the Cognitive Abilities Screening Instrument in patients with dementia |
title_fullStr | Test-retest reliability and minimal detectable change of the Cognitive Abilities Screening Instrument in patients with dementia |
title_full_unstemmed | Test-retest reliability and minimal detectable change of the Cognitive Abilities Screening Instrument in patients with dementia |
title_short | Test-retest reliability and minimal detectable change of the Cognitive Abilities Screening Instrument in patients with dementia |
title_sort | test-retest reliability and minimal detectable change of the cognitive abilities screening instrument in patients with dementia |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6504091/ https://www.ncbi.nlm.nih.gov/pubmed/31063491 http://dx.doi.org/10.1371/journal.pone.0216450 |
work_keys_str_mv | AT chiuenchi testretestreliabilityandminimaldetectablechangeofthecognitiveabilitiesscreeninginstrumentinpatientswithdementia AT yippingkeung testretestreliabilityandminimaldetectablechangeofthecognitiveabilitiesscreeninginstrumentinpatientswithdementia AT woopeter testretestreliabilityandminimaldetectablechangeofthecognitiveabilitiesscreeninginstrumentinpatientswithdementia AT linyite testretestreliabilityandminimaldetectablechangeofthecognitiveabilitiesscreeninginstrumentinpatientswithdementia |