Cargando…

The novel latex agglutination turbidimetric immunoassay system for simultaneous measurements of calprotectin and hemoglobin in feces

BACKGROUND/AIMS: Fecal calprotectin (Fcal) as well as the fecal immunochemical test (FIT) are useful biomarkers for detecting activity and mucosal healing in inflammatory bowel diseases. Here, we report the performance of simultaneous measurements of Fcal and FIT for ulcerative colitis (UC) patients...

Descripción completa

Detalles Bibliográficos
Autores principales: Hiraoka, Sakiko, Takashima, Shiho, Inokuchi, Toshihiro, Nakarai, Asuka, Takahara, Masahiro, Harada, Keita, Seki, Yasuhiro, Watanabe, Katsunori, Kato, Jun, Okada, Hiroyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Association for the Study of Intestinal Diseases 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6505093/
https://www.ncbi.nlm.nih.gov/pubmed/30541228
http://dx.doi.org/10.5217/ir.2018.00086
_version_ 1783416687921463296
author Hiraoka, Sakiko
Takashima, Shiho
Inokuchi, Toshihiro
Nakarai, Asuka
Takahara, Masahiro
Harada, Keita
Seki, Yasuhiro
Watanabe, Katsunori
Kato, Jun
Okada, Hiroyuki
author_facet Hiraoka, Sakiko
Takashima, Shiho
Inokuchi, Toshihiro
Nakarai, Asuka
Takahara, Masahiro
Harada, Keita
Seki, Yasuhiro
Watanabe, Katsunori
Kato, Jun
Okada, Hiroyuki
author_sort Hiraoka, Sakiko
collection PubMed
description BACKGROUND/AIMS: Fecal calprotectin (Fcal) as well as the fecal immunochemical test (FIT) are useful biomarkers for detecting activity and mucosal healing in inflammatory bowel diseases. Here, we report the performance of simultaneous measurements of Fcal and FIT for ulcerative colitis (UC) patients using the newly-developed latex agglutination turbidimetric immunoassay (LATIA) system. METHODS: Fcal and hemoglobin were measured by the LATIA system in 152 UC patients who underwent colonoscopy. Fcal was also quantified with a conventional enzyme-linked immunosorbent assay (ELISA). Fecal markers were evaluated in conjunction with the mucosal status of UC, which was assessed via the Mayo endoscopic subscore (MES) classification. RESULTS: The LATIA system could quantify calprotectin and hemoglobin simultaneously with the same fecal samples within 10 minutes. The values of the Fcal-LATIA closely correlated with those of the Fcal-ELISA (Spearman rank correlation coefficient, r=0.84; P<0.0001). The values of Fcal for each assay and the FIT all significantly correlated with the MESs (Spearman rank correlation coefficient, Fcal-LATIA: r=0.58, Fcal-ELISA: r=0.55, and FIT: r=0.72). The mucosal healing predictability (determined by an MES of 0 alone) of the Fcal-LATIA, Fcal-ELISA, and FIT-LATIA with the cutoffs determined by receiver operating characteristic curve analysis was 0.79, 0.78, and 0.92 for sensitivity, respectively, and 0.78, 0.69, and 0.73 for specificity, respectively. CONCLUSIONS: The performance of the novel Fcal-LATIA was equivalent to that of the conventional Fcal assay. Simultaneous measurements with FITs would promote the clinical relevance of fecal biomarkers in UC.
format Online
Article
Text
id pubmed-6505093
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Korean Association for the Study of Intestinal Diseases
record_format MEDLINE/PubMed
spelling pubmed-65050932019-05-20 The novel latex agglutination turbidimetric immunoassay system for simultaneous measurements of calprotectin and hemoglobin in feces Hiraoka, Sakiko Takashima, Shiho Inokuchi, Toshihiro Nakarai, Asuka Takahara, Masahiro Harada, Keita Seki, Yasuhiro Watanabe, Katsunori Kato, Jun Okada, Hiroyuki Intest Res Original Article BACKGROUND/AIMS: Fecal calprotectin (Fcal) as well as the fecal immunochemical test (FIT) are useful biomarkers for detecting activity and mucosal healing in inflammatory bowel diseases. Here, we report the performance of simultaneous measurements of Fcal and FIT for ulcerative colitis (UC) patients using the newly-developed latex agglutination turbidimetric immunoassay (LATIA) system. METHODS: Fcal and hemoglobin were measured by the LATIA system in 152 UC patients who underwent colonoscopy. Fcal was also quantified with a conventional enzyme-linked immunosorbent assay (ELISA). Fecal markers were evaluated in conjunction with the mucosal status of UC, which was assessed via the Mayo endoscopic subscore (MES) classification. RESULTS: The LATIA system could quantify calprotectin and hemoglobin simultaneously with the same fecal samples within 10 minutes. The values of the Fcal-LATIA closely correlated with those of the Fcal-ELISA (Spearman rank correlation coefficient, r=0.84; P<0.0001). The values of Fcal for each assay and the FIT all significantly correlated with the MESs (Spearman rank correlation coefficient, Fcal-LATIA: r=0.58, Fcal-ELISA: r=0.55, and FIT: r=0.72). The mucosal healing predictability (determined by an MES of 0 alone) of the Fcal-LATIA, Fcal-ELISA, and FIT-LATIA with the cutoffs determined by receiver operating characteristic curve analysis was 0.79, 0.78, and 0.92 for sensitivity, respectively, and 0.78, 0.69, and 0.73 for specificity, respectively. CONCLUSIONS: The performance of the novel Fcal-LATIA was equivalent to that of the conventional Fcal assay. Simultaneous measurements with FITs would promote the clinical relevance of fecal biomarkers in UC. Korean Association for the Study of Intestinal Diseases 2019-04 2018-12-14 /pmc/articles/PMC6505093/ /pubmed/30541228 http://dx.doi.org/10.5217/ir.2018.00086 Text en © Copyright 2019. Korean Association for the Study of Intestinal Diseases. All rights reserved. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Hiraoka, Sakiko
Takashima, Shiho
Inokuchi, Toshihiro
Nakarai, Asuka
Takahara, Masahiro
Harada, Keita
Seki, Yasuhiro
Watanabe, Katsunori
Kato, Jun
Okada, Hiroyuki
The novel latex agglutination turbidimetric immunoassay system for simultaneous measurements of calprotectin and hemoglobin in feces
title The novel latex agglutination turbidimetric immunoassay system for simultaneous measurements of calprotectin and hemoglobin in feces
title_full The novel latex agglutination turbidimetric immunoassay system for simultaneous measurements of calprotectin and hemoglobin in feces
title_fullStr The novel latex agglutination turbidimetric immunoassay system for simultaneous measurements of calprotectin and hemoglobin in feces
title_full_unstemmed The novel latex agglutination turbidimetric immunoassay system for simultaneous measurements of calprotectin and hemoglobin in feces
title_short The novel latex agglutination turbidimetric immunoassay system for simultaneous measurements of calprotectin and hemoglobin in feces
title_sort novel latex agglutination turbidimetric immunoassay system for simultaneous measurements of calprotectin and hemoglobin in feces
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6505093/
https://www.ncbi.nlm.nih.gov/pubmed/30541228
http://dx.doi.org/10.5217/ir.2018.00086
work_keys_str_mv AT hiraokasakiko thenovellatexagglutinationturbidimetricimmunoassaysystemforsimultaneousmeasurementsofcalprotectinandhemoglobininfeces
AT takashimashiho thenovellatexagglutinationturbidimetricimmunoassaysystemforsimultaneousmeasurementsofcalprotectinandhemoglobininfeces
AT inokuchitoshihiro thenovellatexagglutinationturbidimetricimmunoassaysystemforsimultaneousmeasurementsofcalprotectinandhemoglobininfeces
AT nakaraiasuka thenovellatexagglutinationturbidimetricimmunoassaysystemforsimultaneousmeasurementsofcalprotectinandhemoglobininfeces
AT takaharamasahiro thenovellatexagglutinationturbidimetricimmunoassaysystemforsimultaneousmeasurementsofcalprotectinandhemoglobininfeces
AT haradakeita thenovellatexagglutinationturbidimetricimmunoassaysystemforsimultaneousmeasurementsofcalprotectinandhemoglobininfeces
AT sekiyasuhiro thenovellatexagglutinationturbidimetricimmunoassaysystemforsimultaneousmeasurementsofcalprotectinandhemoglobininfeces
AT watanabekatsunori thenovellatexagglutinationturbidimetricimmunoassaysystemforsimultaneousmeasurementsofcalprotectinandhemoglobininfeces
AT katojun thenovellatexagglutinationturbidimetricimmunoassaysystemforsimultaneousmeasurementsofcalprotectinandhemoglobininfeces
AT okadahiroyuki thenovellatexagglutinationturbidimetricimmunoassaysystemforsimultaneousmeasurementsofcalprotectinandhemoglobininfeces
AT hiraokasakiko novellatexagglutinationturbidimetricimmunoassaysystemforsimultaneousmeasurementsofcalprotectinandhemoglobininfeces
AT takashimashiho novellatexagglutinationturbidimetricimmunoassaysystemforsimultaneousmeasurementsofcalprotectinandhemoglobininfeces
AT inokuchitoshihiro novellatexagglutinationturbidimetricimmunoassaysystemforsimultaneousmeasurementsofcalprotectinandhemoglobininfeces
AT nakaraiasuka novellatexagglutinationturbidimetricimmunoassaysystemforsimultaneousmeasurementsofcalprotectinandhemoglobininfeces
AT takaharamasahiro novellatexagglutinationturbidimetricimmunoassaysystemforsimultaneousmeasurementsofcalprotectinandhemoglobininfeces
AT haradakeita novellatexagglutinationturbidimetricimmunoassaysystemforsimultaneousmeasurementsofcalprotectinandhemoglobininfeces
AT sekiyasuhiro novellatexagglutinationturbidimetricimmunoassaysystemforsimultaneousmeasurementsofcalprotectinandhemoglobininfeces
AT watanabekatsunori novellatexagglutinationturbidimetricimmunoassaysystemforsimultaneousmeasurementsofcalprotectinandhemoglobininfeces
AT katojun novellatexagglutinationturbidimetricimmunoassaysystemforsimultaneousmeasurementsofcalprotectinandhemoglobininfeces
AT okadahiroyuki novellatexagglutinationturbidimetricimmunoassaysystemforsimultaneousmeasurementsofcalprotectinandhemoglobininfeces