Cargando…

Measuring Free-Living Physical Activity With Three Commercially Available Activity Monitors for Telemonitoring Purposes: Validation Study

BACKGROUND: Remote monitoring of physical activity in patients with chronic conditions could be useful to offer care professionals real-time assessment of their patient’s daily activity pattern to adjust appropriate treatment. However, the validity of commercially available activity trackers that ca...

Descripción completa

Detalles Bibliográficos
Autores principales: Breteler, Martine JM, Janssen, Joris H, Spiering, Wilko, Kalkman, Cor J, van Solinge, Wouter W, Dohmen, Daan AJ
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6505372/
https://www.ncbi.nlm.nih.gov/pubmed/31017587
http://dx.doi.org/10.2196/11489
_version_ 1783416750891597824
author Breteler, Martine JM
Janssen, Joris H
Spiering, Wilko
Kalkman, Cor J
van Solinge, Wouter W
Dohmen, Daan AJ
author_facet Breteler, Martine JM
Janssen, Joris H
Spiering, Wilko
Kalkman, Cor J
van Solinge, Wouter W
Dohmen, Daan AJ
author_sort Breteler, Martine JM
collection PubMed
description BACKGROUND: Remote monitoring of physical activity in patients with chronic conditions could be useful to offer care professionals real-time assessment of their patient’s daily activity pattern to adjust appropriate treatment. However, the validity of commercially available activity trackers that can be used for telemonitoring purposes is limited. OBJECTIVE: The purpose of this study was to test usability and determine the validity of 3 consumer-level activity trackers as a measure of free-living activity. METHODS: A usability evaluation (study 1) and validation study (study 2) were conducted. In study 1, 10 individuals wore one activity tracker for a period of 30 days and filled in a questionnaire on ease of use and wearability. In study 2, we validated three selected activity trackers (Apple Watch, Misfit Shine, and iHealth Edge) and a fourth pedometer (Yamax Digiwalker) against the reference standard (Actigraph GT3X) in 30 healthy participants for 72 hours. Outcome measures were 95% limits of agreement (LoA) and bias (Bland-Altman analysis). Furthermore, median absolute differences (MAD) were calculated. Correction for bias was estimated and validated using leave-one-out cross validation. RESULTS: Usability evaluation of study 1 showed that iHealth Edge and Apple Watch were more comfortable to wear as compared with the Misfit Flash. Therefore, the Misfit Flash was replaced by Misfit Shine in study 2. During study 2, the total number of steps of the reference standard was 21,527 (interquartile range, IQR 17,475-24,809). Bias and LoA for number of steps from the Apple Watch and iHealth Edge were 968 (IQR −5478 to 7414) and 2021 (IQR −4994 to 9036) steps. For Misfit Shine and Yamax Digiwalker, bias was −1874 and 2004, both with wide LoA of (13,869 to 10,121) and (−10,932 to 14,940) steps, respectively. The Apple Watch noted the smallest MAD of 7.7% with the Actigraph, whereas the Yamax Digiwalker noted the highest MAD (20.3%). After leave-one-out cross validation, accuracy estimates of MAD of the iHealth Edge and Misfit Shine were within acceptable limits with 10.7% and 11.3%, respectively. CONCLUSIONS: Overall, the Apple Watch and iHealth Edge were positively evaluated after wearing. Validity varied widely between devices, with the Apple Watch being the most accurate and Yamax Digiwalker the least accurate for step count in free-living conditions. The iHealth Edge underestimates number of steps but can be considered reliable for activity monitoring after correction for bias. Misfit Shine overestimated number of steps and cannot be considered suitable for step count because of the low agreement. Future studies should focus on the added value of remotely monitoring activity patterns over time in chronic patients.
format Online
Article
Text
id pubmed-6505372
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-65053722019-06-03 Measuring Free-Living Physical Activity With Three Commercially Available Activity Monitors for Telemonitoring Purposes: Validation Study Breteler, Martine JM Janssen, Joris H Spiering, Wilko Kalkman, Cor J van Solinge, Wouter W Dohmen, Daan AJ JMIR Form Res Original Paper BACKGROUND: Remote monitoring of physical activity in patients with chronic conditions could be useful to offer care professionals real-time assessment of their patient’s daily activity pattern to adjust appropriate treatment. However, the validity of commercially available activity trackers that can be used for telemonitoring purposes is limited. OBJECTIVE: The purpose of this study was to test usability and determine the validity of 3 consumer-level activity trackers as a measure of free-living activity. METHODS: A usability evaluation (study 1) and validation study (study 2) were conducted. In study 1, 10 individuals wore one activity tracker for a period of 30 days and filled in a questionnaire on ease of use and wearability. In study 2, we validated three selected activity trackers (Apple Watch, Misfit Shine, and iHealth Edge) and a fourth pedometer (Yamax Digiwalker) against the reference standard (Actigraph GT3X) in 30 healthy participants for 72 hours. Outcome measures were 95% limits of agreement (LoA) and bias (Bland-Altman analysis). Furthermore, median absolute differences (MAD) were calculated. Correction for bias was estimated and validated using leave-one-out cross validation. RESULTS: Usability evaluation of study 1 showed that iHealth Edge and Apple Watch were more comfortable to wear as compared with the Misfit Flash. Therefore, the Misfit Flash was replaced by Misfit Shine in study 2. During study 2, the total number of steps of the reference standard was 21,527 (interquartile range, IQR 17,475-24,809). Bias and LoA for number of steps from the Apple Watch and iHealth Edge were 968 (IQR −5478 to 7414) and 2021 (IQR −4994 to 9036) steps. For Misfit Shine and Yamax Digiwalker, bias was −1874 and 2004, both with wide LoA of (13,869 to 10,121) and (−10,932 to 14,940) steps, respectively. The Apple Watch noted the smallest MAD of 7.7% with the Actigraph, whereas the Yamax Digiwalker noted the highest MAD (20.3%). After leave-one-out cross validation, accuracy estimates of MAD of the iHealth Edge and Misfit Shine were within acceptable limits with 10.7% and 11.3%, respectively. CONCLUSIONS: Overall, the Apple Watch and iHealth Edge were positively evaluated after wearing. Validity varied widely between devices, with the Apple Watch being the most accurate and Yamax Digiwalker the least accurate for step count in free-living conditions. The iHealth Edge underestimates number of steps but can be considered reliable for activity monitoring after correction for bias. Misfit Shine overestimated number of steps and cannot be considered suitable for step count because of the low agreement. Future studies should focus on the added value of remotely monitoring activity patterns over time in chronic patients. JMIR Publications 2019-04-24 /pmc/articles/PMC6505372/ /pubmed/31017587 http://dx.doi.org/10.2196/11489 Text en ©Martine JM Breteler, Joris H Janssen, Wilko Spiering, Cor J Kalkman, Wouter W van Solinge, Daan AJ Dohmen. Originally published in JMIR Formative Research (http://formative.jmir.org), 24.04.2019. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Formative Research, is properly cited. The complete bibliographic information, a link to the original publication on http://formative.jmir.org, as well as this copyright and license information must be included.
spellingShingle Original Paper
Breteler, Martine JM
Janssen, Joris H
Spiering, Wilko
Kalkman, Cor J
van Solinge, Wouter W
Dohmen, Daan AJ
Measuring Free-Living Physical Activity With Three Commercially Available Activity Monitors for Telemonitoring Purposes: Validation Study
title Measuring Free-Living Physical Activity With Three Commercially Available Activity Monitors for Telemonitoring Purposes: Validation Study
title_full Measuring Free-Living Physical Activity With Three Commercially Available Activity Monitors for Telemonitoring Purposes: Validation Study
title_fullStr Measuring Free-Living Physical Activity With Three Commercially Available Activity Monitors for Telemonitoring Purposes: Validation Study
title_full_unstemmed Measuring Free-Living Physical Activity With Three Commercially Available Activity Monitors for Telemonitoring Purposes: Validation Study
title_short Measuring Free-Living Physical Activity With Three Commercially Available Activity Monitors for Telemonitoring Purposes: Validation Study
title_sort measuring free-living physical activity with three commercially available activity monitors for telemonitoring purposes: validation study
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6505372/
https://www.ncbi.nlm.nih.gov/pubmed/31017587
http://dx.doi.org/10.2196/11489
work_keys_str_mv AT bretelermartinejm measuringfreelivingphysicalactivitywiththreecommerciallyavailableactivitymonitorsfortelemonitoringpurposesvalidationstudy
AT janssenjorish measuringfreelivingphysicalactivitywiththreecommerciallyavailableactivitymonitorsfortelemonitoringpurposesvalidationstudy
AT spieringwilko measuringfreelivingphysicalactivitywiththreecommerciallyavailableactivitymonitorsfortelemonitoringpurposesvalidationstudy
AT kalkmancorj measuringfreelivingphysicalactivitywiththreecommerciallyavailableactivitymonitorsfortelemonitoringpurposesvalidationstudy
AT vansolingewouterw measuringfreelivingphysicalactivitywiththreecommerciallyavailableactivitymonitorsfortelemonitoringpurposesvalidationstudy
AT dohmendaanaj measuringfreelivingphysicalactivitywiththreecommerciallyavailableactivitymonitorsfortelemonitoringpurposesvalidationstudy