Cargando…

Effect of Disinfectants on Mechanical Properties of Orthodontic Acrylics

OBJECTIVE: Infection control protocols in dentistry dictate that orthodontic acrylics have to be disinfected. No specific products for orthodontic acrylics are available. The objective of this study was to investigate the influence of chemical disinfectants on mechanical properties of orthodontic ac...

Descripción completa

Detalles Bibliográficos
Autores principales: Bensel, Tobias, Bock, Jens J., Kebernik, Anne, Arnold, Christin, Mansour, Sonia, Boeckler, Arne F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6507238/
https://www.ncbi.nlm.nih.gov/pubmed/31178912
http://dx.doi.org/10.1155/2019/1096208
_version_ 1783416991904694272
author Bensel, Tobias
Bock, Jens J.
Kebernik, Anne
Arnold, Christin
Mansour, Sonia
Boeckler, Arne F.
author_facet Bensel, Tobias
Bock, Jens J.
Kebernik, Anne
Arnold, Christin
Mansour, Sonia
Boeckler, Arne F.
author_sort Bensel, Tobias
collection PubMed
description OBJECTIVE: Infection control protocols in dentistry dictate that orthodontic acrylics have to be disinfected. No specific products for orthodontic acrylics are available. The objective of this study was to investigate the influence of chemical disinfectants on mechanical properties of orthodontic acrylics. MATERIALS AND METHODS: 260 test specimens of two cold-curing orthodontic acrylics were manufactured. Three chemical disinfecting agents were tested: Impresept, D050 Instru-Gen, and Stammopur DR. Test specimens were stored in distilled water and divided into test groups. E-Modulus, flexural strength, macro hardness, micro hardness, average roughness, and colour change were measured. RESULTS: Disinfection agents showed no significant influence on E-modulus. Values ranged from 1783.80 ± 163.80 MPa (Forestacryl colourless) to 2474.00 ± 135.00 MPa (Orthocryl green) after storage in distilled water. Disinfection agents performed no significant influence on flexural strength. Values ranged from 18.64±1.59 N/mm(2) (Forestacryl colourless) to 25.64 ± 1.43 N/mm(2) (Orthocryl green) after storage in distilled water. Orthocryl colourless showed a reduction of the macro hardness after disinfection (Stammopur DR (p≤0.001), D050 Instru-Gen (p≤0.037)). Disinfection of Orthocryl green with D050 Instru-Gen (p<0.001) and Forestacryl colourless with Impresept (p≤0.001) led to a reduction of macro hardness. Micro hardness of Orthocryl colourless altered significantly after disinfection with D050 Instru-Gen (p≤0.001). Micro hardness of Forestacryl colourless increased (Impresept (p≤0.039)) and decreased (Stammopur DR (p≤0.006) Instru-Gen (p≤0.001)) after disinfection. Average roughness did not change significantly (Orthocryl colourless). Forestacryl colourless performed a significant change after disinfection with Stammopur DR (p≤0.05). This is also true for the disinfection of Orthocryl green and Forestacryl pink with Instru-Gen (p≤0.05). Disinfection performed no significant influence on colour change. ΔE-values were in a range of 1 to 2. CONCLUSIONS: Some orthodontic acrylics disinfection caused significant changes of determined parameters. Changes were specific for the applied disinfectant and tested orthodontic acrylic. Further studies should verify the impact of long-term disinfection intervals. Thus, from manufacturers of orthodontic acrylics recommendations for appropriate disinfectants would be desirable.
format Online
Article
Text
id pubmed-6507238
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-65072382019-06-09 Effect of Disinfectants on Mechanical Properties of Orthodontic Acrylics Bensel, Tobias Bock, Jens J. Kebernik, Anne Arnold, Christin Mansour, Sonia Boeckler, Arne F. Int J Biomater Research Article OBJECTIVE: Infection control protocols in dentistry dictate that orthodontic acrylics have to be disinfected. No specific products for orthodontic acrylics are available. The objective of this study was to investigate the influence of chemical disinfectants on mechanical properties of orthodontic acrylics. MATERIALS AND METHODS: 260 test specimens of two cold-curing orthodontic acrylics were manufactured. Three chemical disinfecting agents were tested: Impresept, D050 Instru-Gen, and Stammopur DR. Test specimens were stored in distilled water and divided into test groups. E-Modulus, flexural strength, macro hardness, micro hardness, average roughness, and colour change were measured. RESULTS: Disinfection agents showed no significant influence on E-modulus. Values ranged from 1783.80 ± 163.80 MPa (Forestacryl colourless) to 2474.00 ± 135.00 MPa (Orthocryl green) after storage in distilled water. Disinfection agents performed no significant influence on flexural strength. Values ranged from 18.64±1.59 N/mm(2) (Forestacryl colourless) to 25.64 ± 1.43 N/mm(2) (Orthocryl green) after storage in distilled water. Orthocryl colourless showed a reduction of the macro hardness after disinfection (Stammopur DR (p≤0.001), D050 Instru-Gen (p≤0.037)). Disinfection of Orthocryl green with D050 Instru-Gen (p<0.001) and Forestacryl colourless with Impresept (p≤0.001) led to a reduction of macro hardness. Micro hardness of Orthocryl colourless altered significantly after disinfection with D050 Instru-Gen (p≤0.001). Micro hardness of Forestacryl colourless increased (Impresept (p≤0.039)) and decreased (Stammopur DR (p≤0.006) Instru-Gen (p≤0.001)) after disinfection. Average roughness did not change significantly (Orthocryl colourless). Forestacryl colourless performed a significant change after disinfection with Stammopur DR (p≤0.05). This is also true for the disinfection of Orthocryl green and Forestacryl pink with Instru-Gen (p≤0.05). Disinfection performed no significant influence on colour change. ΔE-values were in a range of 1 to 2. CONCLUSIONS: Some orthodontic acrylics disinfection caused significant changes of determined parameters. Changes were specific for the applied disinfectant and tested orthodontic acrylic. Further studies should verify the impact of long-term disinfection intervals. Thus, from manufacturers of orthodontic acrylics recommendations for appropriate disinfectants would be desirable. Hindawi 2019-04-24 /pmc/articles/PMC6507238/ /pubmed/31178912 http://dx.doi.org/10.1155/2019/1096208 Text en Copyright © 2019 Tobias Bensel et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Bensel, Tobias
Bock, Jens J.
Kebernik, Anne
Arnold, Christin
Mansour, Sonia
Boeckler, Arne F.
Effect of Disinfectants on Mechanical Properties of Orthodontic Acrylics
title Effect of Disinfectants on Mechanical Properties of Orthodontic Acrylics
title_full Effect of Disinfectants on Mechanical Properties of Orthodontic Acrylics
title_fullStr Effect of Disinfectants on Mechanical Properties of Orthodontic Acrylics
title_full_unstemmed Effect of Disinfectants on Mechanical Properties of Orthodontic Acrylics
title_short Effect of Disinfectants on Mechanical Properties of Orthodontic Acrylics
title_sort effect of disinfectants on mechanical properties of orthodontic acrylics
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6507238/
https://www.ncbi.nlm.nih.gov/pubmed/31178912
http://dx.doi.org/10.1155/2019/1096208
work_keys_str_mv AT benseltobias effectofdisinfectantsonmechanicalpropertiesoforthodonticacrylics
AT bockjensj effectofdisinfectantsonmechanicalpropertiesoforthodonticacrylics
AT kebernikanne effectofdisinfectantsonmechanicalpropertiesoforthodonticacrylics
AT arnoldchristin effectofdisinfectantsonmechanicalpropertiesoforthodonticacrylics
AT mansoursonia effectofdisinfectantsonmechanicalpropertiesoforthodonticacrylics
AT boecklerarnef effectofdisinfectantsonmechanicalpropertiesoforthodonticacrylics