Cargando…

Diagnostic value of ultrasound score, color Doppler ultrasound RI and spiral CT for ovarian tumors

Diagnostic value of ultrasound score, color Doppler ultrasound resistance index (RI) and spiral computed tomography (CT) for ovarian tumors was investigated. In total 224 patients pathologically diagnosed with ovarian tumor after operation in Cangzhou Central Hospital were selected, including 120 pa...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Li, Xuan, Zhidong, Wang, Yu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6507346/
https://www.ncbi.nlm.nih.gov/pubmed/31186769
http://dx.doi.org/10.3892/ol.2019.10215
_version_ 1783417012829028352
author Zhou, Li
Xuan, Zhidong
Wang, Yu
author_facet Zhou, Li
Xuan, Zhidong
Wang, Yu
author_sort Zhou, Li
collection PubMed
description Diagnostic value of ultrasound score, color Doppler ultrasound resistance index (RI) and spiral computed tomography (CT) for ovarian tumors was investigated. In total 224 patients pathologically diagnosed with ovarian tumor after operation in Cangzhou Central Hospital were selected, including 120 patients with benign ovarian tumor and 104 patients with malignant ovarian tumor. Patients with benign and malignant tumors were scored according to the ultrasound scoring criteria. The color Doppler ultrasound examination was performed and the corresponding RI was recorded. At the same time, 64-slice spiral CT was performed, and results were compared with the postoperative pathological diagnosis. Also, the sensitivity, specificity and accuracy of the combined application of the three methods were detected. The RI value of benign ovarian tumor was higher than that of malignant ovarian tumor, displaying statistically significant difference (P<0.05). The sensitivity, specificity and accuracy of the combined application of the three methods were 96.49, 90.91 and 93.75%, respectively. Ultrasound scoring, color Doppler ultrasound RI and 64-slice spiral CT have good diagnostic value for ovarian tumor, and the diagnostic accuracy rate of the combined application is higher. Therefore, different examination methods can be selected in clinic according to the different situations.
format Online
Article
Text
id pubmed-6507346
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher D.A. Spandidos
record_format MEDLINE/PubMed
spelling pubmed-65073462019-06-11 Diagnostic value of ultrasound score, color Doppler ultrasound RI and spiral CT for ovarian tumors Zhou, Li Xuan, Zhidong Wang, Yu Oncol Lett Articles Diagnostic value of ultrasound score, color Doppler ultrasound resistance index (RI) and spiral computed tomography (CT) for ovarian tumors was investigated. In total 224 patients pathologically diagnosed with ovarian tumor after operation in Cangzhou Central Hospital were selected, including 120 patients with benign ovarian tumor and 104 patients with malignant ovarian tumor. Patients with benign and malignant tumors were scored according to the ultrasound scoring criteria. The color Doppler ultrasound examination was performed and the corresponding RI was recorded. At the same time, 64-slice spiral CT was performed, and results were compared with the postoperative pathological diagnosis. Also, the sensitivity, specificity and accuracy of the combined application of the three methods were detected. The RI value of benign ovarian tumor was higher than that of malignant ovarian tumor, displaying statistically significant difference (P<0.05). The sensitivity, specificity and accuracy of the combined application of the three methods were 96.49, 90.91 and 93.75%, respectively. Ultrasound scoring, color Doppler ultrasound RI and 64-slice spiral CT have good diagnostic value for ovarian tumor, and the diagnostic accuracy rate of the combined application is higher. Therefore, different examination methods can be selected in clinic according to the different situations. D.A. Spandidos 2019-06 2019-04-04 /pmc/articles/PMC6507346/ /pubmed/31186769 http://dx.doi.org/10.3892/ol.2019.10215 Text en Copyright: © Zhou et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
spellingShingle Articles
Zhou, Li
Xuan, Zhidong
Wang, Yu
Diagnostic value of ultrasound score, color Doppler ultrasound RI and spiral CT for ovarian tumors
title Diagnostic value of ultrasound score, color Doppler ultrasound RI and spiral CT for ovarian tumors
title_full Diagnostic value of ultrasound score, color Doppler ultrasound RI and spiral CT for ovarian tumors
title_fullStr Diagnostic value of ultrasound score, color Doppler ultrasound RI and spiral CT for ovarian tumors
title_full_unstemmed Diagnostic value of ultrasound score, color Doppler ultrasound RI and spiral CT for ovarian tumors
title_short Diagnostic value of ultrasound score, color Doppler ultrasound RI and spiral CT for ovarian tumors
title_sort diagnostic value of ultrasound score, color doppler ultrasound ri and spiral ct for ovarian tumors
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6507346/
https://www.ncbi.nlm.nih.gov/pubmed/31186769
http://dx.doi.org/10.3892/ol.2019.10215
work_keys_str_mv AT zhouli diagnosticvalueofultrasoundscorecolordopplerultrasoundriandspiralctforovariantumors
AT xuanzhidong diagnosticvalueofultrasoundscorecolordopplerultrasoundriandspiralctforovariantumors
AT wangyu diagnosticvalueofultrasoundscorecolordopplerultrasoundriandspiralctforovariantumors