Cargando…

Comparison of diagnostic values between CA125 combined with CA199 and ultrasound combined with CT in ovarian cancer

Application values of CA125 combined with CA199 and ultrasound combined with computed tomography (CT) in the clinical diagnosis of ovarian cancer were compared. A retrospective analysis was performed on 168 ovarian cancer patients admitted to the Department of Gynecology in Jining No.1 People's...

Descripción completa

Detalles Bibliográficos
Autores principales: Guo, Bingcheng, Lian, Wei, Liu, Shuai, Cao, Yingchun, Liu, Jianhua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6507457/
https://www.ncbi.nlm.nih.gov/pubmed/31186773
http://dx.doi.org/10.3892/ol.2019.10264
_version_ 1783417030187155456
author Guo, Bingcheng
Lian, Wei
Liu, Shuai
Cao, Yingchun
Liu, Jianhua
author_facet Guo, Bingcheng
Lian, Wei
Liu, Shuai
Cao, Yingchun
Liu, Jianhua
author_sort Guo, Bingcheng
collection PubMed
description Application values of CA125 combined with CA199 and ultrasound combined with computed tomography (CT) in the clinical diagnosis of ovarian cancer were compared. A retrospective analysis was performed on 168 ovarian cancer patients admitted to the Department of Gynecology in Jining No.1 People's Hospital from July 2013 to March 2016. Of the patients 107 with malignant tumors were in the malignant group, and 61 patients with benign tumors were in the benign group. Another 98 healthy controls in the same period were in the normal group. Chemiluminescence was used for the detection of levels of tumor markers CA125 and CA199 in the serum of all patients. CA125 combined with CA199 and color Doppler ultrasound combined with CT scan were used to diagnose and analyze the sensitivity, specificity, accuracy, and positive detection rate of ovarian cancer patients at different stages. The sensitivity, specificity and diagnostic coincidence rate of ultrasound combined with CT in the diagnosis of ovarian cancer were 97.20, 80.32 and 91.07%, respectively, which were significantly higher than the 92.52, 73.77 and 85.71% of serum CA125 combined with CA199. The positive detection rate of ultrasound combined with CT in the early diagnosis of ovarian cancer was 93.55%, higher than 83.87% of CA125 combined with CA199. The sensitivity, specificity, coincidence rate and positive detection rate of ultrasound combined with CT in the diagnosis were higher than those of CA125 combined with CA199. In the actual diagnosis process, these two diagnostic schemes can be selectively and comprehensively applied, so as to make a correct diagnosis, which is of great significance for reducing patient mortality.
format Online
Article
Text
id pubmed-6507457
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher D.A. Spandidos
record_format MEDLINE/PubMed
spelling pubmed-65074572019-06-11 Comparison of diagnostic values between CA125 combined with CA199 and ultrasound combined with CT in ovarian cancer Guo, Bingcheng Lian, Wei Liu, Shuai Cao, Yingchun Liu, Jianhua Oncol Lett Articles Application values of CA125 combined with CA199 and ultrasound combined with computed tomography (CT) in the clinical diagnosis of ovarian cancer were compared. A retrospective analysis was performed on 168 ovarian cancer patients admitted to the Department of Gynecology in Jining No.1 People's Hospital from July 2013 to March 2016. Of the patients 107 with malignant tumors were in the malignant group, and 61 patients with benign tumors were in the benign group. Another 98 healthy controls in the same period were in the normal group. Chemiluminescence was used for the detection of levels of tumor markers CA125 and CA199 in the serum of all patients. CA125 combined with CA199 and color Doppler ultrasound combined with CT scan were used to diagnose and analyze the sensitivity, specificity, accuracy, and positive detection rate of ovarian cancer patients at different stages. The sensitivity, specificity and diagnostic coincidence rate of ultrasound combined with CT in the diagnosis of ovarian cancer were 97.20, 80.32 and 91.07%, respectively, which were significantly higher than the 92.52, 73.77 and 85.71% of serum CA125 combined with CA199. The positive detection rate of ultrasound combined with CT in the early diagnosis of ovarian cancer was 93.55%, higher than 83.87% of CA125 combined with CA199. The sensitivity, specificity, coincidence rate and positive detection rate of ultrasound combined with CT in the diagnosis were higher than those of CA125 combined with CA199. In the actual diagnosis process, these two diagnostic schemes can be selectively and comprehensively applied, so as to make a correct diagnosis, which is of great significance for reducing patient mortality. D.A. Spandidos 2019-06 2019-04-18 /pmc/articles/PMC6507457/ /pubmed/31186773 http://dx.doi.org/10.3892/ol.2019.10264 Text en Copyright: © Guo et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
spellingShingle Articles
Guo, Bingcheng
Lian, Wei
Liu, Shuai
Cao, Yingchun
Liu, Jianhua
Comparison of diagnostic values between CA125 combined with CA199 and ultrasound combined with CT in ovarian cancer
title Comparison of diagnostic values between CA125 combined with CA199 and ultrasound combined with CT in ovarian cancer
title_full Comparison of diagnostic values between CA125 combined with CA199 and ultrasound combined with CT in ovarian cancer
title_fullStr Comparison of diagnostic values between CA125 combined with CA199 and ultrasound combined with CT in ovarian cancer
title_full_unstemmed Comparison of diagnostic values between CA125 combined with CA199 and ultrasound combined with CT in ovarian cancer
title_short Comparison of diagnostic values between CA125 combined with CA199 and ultrasound combined with CT in ovarian cancer
title_sort comparison of diagnostic values between ca125 combined with ca199 and ultrasound combined with ct in ovarian cancer
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6507457/
https://www.ncbi.nlm.nih.gov/pubmed/31186773
http://dx.doi.org/10.3892/ol.2019.10264
work_keys_str_mv AT guobingcheng comparisonofdiagnosticvaluesbetweenca125combinedwithca199andultrasoundcombinedwithctinovariancancer
AT lianwei comparisonofdiagnosticvaluesbetweenca125combinedwithca199andultrasoundcombinedwithctinovariancancer
AT liushuai comparisonofdiagnosticvaluesbetweenca125combinedwithca199andultrasoundcombinedwithctinovariancancer
AT caoyingchun comparisonofdiagnosticvaluesbetweenca125combinedwithca199andultrasoundcombinedwithctinovariancancer
AT liujianhua comparisonofdiagnosticvaluesbetweenca125combinedwithca199andultrasoundcombinedwithctinovariancancer