Cargando…
Comparison of diagnostic values between CA125 combined with CA199 and ultrasound combined with CT in ovarian cancer
Application values of CA125 combined with CA199 and ultrasound combined with computed tomography (CT) in the clinical diagnosis of ovarian cancer were compared. A retrospective analysis was performed on 168 ovarian cancer patients admitted to the Department of Gynecology in Jining No.1 People's...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
D.A. Spandidos
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6507457/ https://www.ncbi.nlm.nih.gov/pubmed/31186773 http://dx.doi.org/10.3892/ol.2019.10264 |
_version_ | 1783417030187155456 |
---|---|
author | Guo, Bingcheng Lian, Wei Liu, Shuai Cao, Yingchun Liu, Jianhua |
author_facet | Guo, Bingcheng Lian, Wei Liu, Shuai Cao, Yingchun Liu, Jianhua |
author_sort | Guo, Bingcheng |
collection | PubMed |
description | Application values of CA125 combined with CA199 and ultrasound combined with computed tomography (CT) in the clinical diagnosis of ovarian cancer were compared. A retrospective analysis was performed on 168 ovarian cancer patients admitted to the Department of Gynecology in Jining No.1 People's Hospital from July 2013 to March 2016. Of the patients 107 with malignant tumors were in the malignant group, and 61 patients with benign tumors were in the benign group. Another 98 healthy controls in the same period were in the normal group. Chemiluminescence was used for the detection of levels of tumor markers CA125 and CA199 in the serum of all patients. CA125 combined with CA199 and color Doppler ultrasound combined with CT scan were used to diagnose and analyze the sensitivity, specificity, accuracy, and positive detection rate of ovarian cancer patients at different stages. The sensitivity, specificity and diagnostic coincidence rate of ultrasound combined with CT in the diagnosis of ovarian cancer were 97.20, 80.32 and 91.07%, respectively, which were significantly higher than the 92.52, 73.77 and 85.71% of serum CA125 combined with CA199. The positive detection rate of ultrasound combined with CT in the early diagnosis of ovarian cancer was 93.55%, higher than 83.87% of CA125 combined with CA199. The sensitivity, specificity, coincidence rate and positive detection rate of ultrasound combined with CT in the diagnosis were higher than those of CA125 combined with CA199. In the actual diagnosis process, these two diagnostic schemes can be selectively and comprehensively applied, so as to make a correct diagnosis, which is of great significance for reducing patient mortality. |
format | Online Article Text |
id | pubmed-6507457 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | D.A. Spandidos |
record_format | MEDLINE/PubMed |
spelling | pubmed-65074572019-06-11 Comparison of diagnostic values between CA125 combined with CA199 and ultrasound combined with CT in ovarian cancer Guo, Bingcheng Lian, Wei Liu, Shuai Cao, Yingchun Liu, Jianhua Oncol Lett Articles Application values of CA125 combined with CA199 and ultrasound combined with computed tomography (CT) in the clinical diagnosis of ovarian cancer were compared. A retrospective analysis was performed on 168 ovarian cancer patients admitted to the Department of Gynecology in Jining No.1 People's Hospital from July 2013 to March 2016. Of the patients 107 with malignant tumors were in the malignant group, and 61 patients with benign tumors were in the benign group. Another 98 healthy controls in the same period were in the normal group. Chemiluminescence was used for the detection of levels of tumor markers CA125 and CA199 in the serum of all patients. CA125 combined with CA199 and color Doppler ultrasound combined with CT scan were used to diagnose and analyze the sensitivity, specificity, accuracy, and positive detection rate of ovarian cancer patients at different stages. The sensitivity, specificity and diagnostic coincidence rate of ultrasound combined with CT in the diagnosis of ovarian cancer were 97.20, 80.32 and 91.07%, respectively, which were significantly higher than the 92.52, 73.77 and 85.71% of serum CA125 combined with CA199. The positive detection rate of ultrasound combined with CT in the early diagnosis of ovarian cancer was 93.55%, higher than 83.87% of CA125 combined with CA199. The sensitivity, specificity, coincidence rate and positive detection rate of ultrasound combined with CT in the diagnosis were higher than those of CA125 combined with CA199. In the actual diagnosis process, these two diagnostic schemes can be selectively and comprehensively applied, so as to make a correct diagnosis, which is of great significance for reducing patient mortality. D.A. Spandidos 2019-06 2019-04-18 /pmc/articles/PMC6507457/ /pubmed/31186773 http://dx.doi.org/10.3892/ol.2019.10264 Text en Copyright: © Guo et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made. |
spellingShingle | Articles Guo, Bingcheng Lian, Wei Liu, Shuai Cao, Yingchun Liu, Jianhua Comparison of diagnostic values between CA125 combined with CA199 and ultrasound combined with CT in ovarian cancer |
title | Comparison of diagnostic values between CA125 combined with CA199 and ultrasound combined with CT in ovarian cancer |
title_full | Comparison of diagnostic values between CA125 combined with CA199 and ultrasound combined with CT in ovarian cancer |
title_fullStr | Comparison of diagnostic values between CA125 combined with CA199 and ultrasound combined with CT in ovarian cancer |
title_full_unstemmed | Comparison of diagnostic values between CA125 combined with CA199 and ultrasound combined with CT in ovarian cancer |
title_short | Comparison of diagnostic values between CA125 combined with CA199 and ultrasound combined with CT in ovarian cancer |
title_sort | comparison of diagnostic values between ca125 combined with ca199 and ultrasound combined with ct in ovarian cancer |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6507457/ https://www.ncbi.nlm.nih.gov/pubmed/31186773 http://dx.doi.org/10.3892/ol.2019.10264 |
work_keys_str_mv | AT guobingcheng comparisonofdiagnosticvaluesbetweenca125combinedwithca199andultrasoundcombinedwithctinovariancancer AT lianwei comparisonofdiagnosticvaluesbetweenca125combinedwithca199andultrasoundcombinedwithctinovariancancer AT liushuai comparisonofdiagnosticvaluesbetweenca125combinedwithca199andultrasoundcombinedwithctinovariancancer AT caoyingchun comparisonofdiagnosticvaluesbetweenca125combinedwithca199andultrasoundcombinedwithctinovariancancer AT liujianhua comparisonofdiagnosticvaluesbetweenca125combinedwithca199andultrasoundcombinedwithctinovariancancer |