Cargando…

Preliminary Indoor Radon Measurements Near Faults Crossing Urban Areas of Mt. Etna Volcano (Italy)

The slopes of Etna are crossed by numerous active faults that traverse various towns and villages. These faults pose a two-fold problem for the local people: on one hand, they cause frequent damage to houses and breakage of roads, while on the other they constitute a preferential route for the risin...

Descripción completa

Detalles Bibliográficos
Autores principales: Neri, Marco, Giammanco, Salvatore, Leonardi, Anna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6509806/
https://www.ncbi.nlm.nih.gov/pubmed/31131269
http://dx.doi.org/10.3389/fpubh.2019.00105
_version_ 1783417321027534848
author Neri, Marco
Giammanco, Salvatore
Leonardi, Anna
author_facet Neri, Marco
Giammanco, Salvatore
Leonardi, Anna
author_sort Neri, Marco
collection PubMed
description The slopes of Etna are crossed by numerous active faults that traverse various towns and villages. These faults pose a two-fold problem for the local people: on one hand, they cause frequent damage to houses and breakage of roads, while on the other they constitute a preferential route for the rising of crustal and sub-crustal gases, including radon, toward the surface. Various recent studies on the volcano confirm a high level of radon degassing measured both in the soil (> 10,000 Bq/m(3)), and inside homes (> 2,000 Bq/m(3)). For this reason, we felt the need to deepen our knowledge on the radon present in the Etnean area, focusing in particular on indoor radon pollution that, as widely recognized, is among the main causes of cancer largely (but not exclusively) of the respiratory system. Firstly, since 2005 we made a broad surface survey that revealed very high radon emissions from soils near active faults on Etna. Typical background soil activity on Etna were <1,000 Bq/m(3), whereas in areas of stronger soil degassing, activity values up to ~60,000 Bq/m(3) were measured. Furthermore, since late 2015 we have performed continuous indoor radon monitoring inside seven houses, some of which located close to degassing faults on the eastern, southern and south-western flanks of the volcano. Indoor radon concentration varied according to the season of the year, but above all, they changed according to the geology and tectonic setting of the substratum of the monitored houses. In one case, indoor radon concentration reached 3,549 Bq/m(3) and remained > 1,000 Bq/m(3) for several consecutive months, highlighting a potential health problem for those living in such environments. In other cases, the construction features of the houses and/or the materials used seemed to play an important role in the mitigation of indoor radon accumulation, even in the presence of intensely degassing soils. These preliminary data demonstrate the need to deepen the studies, extending indoor radon measurements to other urban areas, in order to monitor the health hazard for the Etna population, amounting to about one million people.
format Online
Article
Text
id pubmed-6509806
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-65098062019-05-24 Preliminary Indoor Radon Measurements Near Faults Crossing Urban Areas of Mt. Etna Volcano (Italy) Neri, Marco Giammanco, Salvatore Leonardi, Anna Front Public Health Public Health The slopes of Etna are crossed by numerous active faults that traverse various towns and villages. These faults pose a two-fold problem for the local people: on one hand, they cause frequent damage to houses and breakage of roads, while on the other they constitute a preferential route for the rising of crustal and sub-crustal gases, including radon, toward the surface. Various recent studies on the volcano confirm a high level of radon degassing measured both in the soil (> 10,000 Bq/m(3)), and inside homes (> 2,000 Bq/m(3)). For this reason, we felt the need to deepen our knowledge on the radon present in the Etnean area, focusing in particular on indoor radon pollution that, as widely recognized, is among the main causes of cancer largely (but not exclusively) of the respiratory system. Firstly, since 2005 we made a broad surface survey that revealed very high radon emissions from soils near active faults on Etna. Typical background soil activity on Etna were <1,000 Bq/m(3), whereas in areas of stronger soil degassing, activity values up to ~60,000 Bq/m(3) were measured. Furthermore, since late 2015 we have performed continuous indoor radon monitoring inside seven houses, some of which located close to degassing faults on the eastern, southern and south-western flanks of the volcano. Indoor radon concentration varied according to the season of the year, but above all, they changed according to the geology and tectonic setting of the substratum of the monitored houses. In one case, indoor radon concentration reached 3,549 Bq/m(3) and remained > 1,000 Bq/m(3) for several consecutive months, highlighting a potential health problem for those living in such environments. In other cases, the construction features of the houses and/or the materials used seemed to play an important role in the mitigation of indoor radon accumulation, even in the presence of intensely degassing soils. These preliminary data demonstrate the need to deepen the studies, extending indoor radon measurements to other urban areas, in order to monitor the health hazard for the Etna population, amounting to about one million people. Frontiers Media S.A. 2019-05-03 /pmc/articles/PMC6509806/ /pubmed/31131269 http://dx.doi.org/10.3389/fpubh.2019.00105 Text en Copyright © 2019 Neri, Giammanco and Leonardi. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Public Health
Neri, Marco
Giammanco, Salvatore
Leonardi, Anna
Preliminary Indoor Radon Measurements Near Faults Crossing Urban Areas of Mt. Etna Volcano (Italy)
title Preliminary Indoor Radon Measurements Near Faults Crossing Urban Areas of Mt. Etna Volcano (Italy)
title_full Preliminary Indoor Radon Measurements Near Faults Crossing Urban Areas of Mt. Etna Volcano (Italy)
title_fullStr Preliminary Indoor Radon Measurements Near Faults Crossing Urban Areas of Mt. Etna Volcano (Italy)
title_full_unstemmed Preliminary Indoor Radon Measurements Near Faults Crossing Urban Areas of Mt. Etna Volcano (Italy)
title_short Preliminary Indoor Radon Measurements Near Faults Crossing Urban Areas of Mt. Etna Volcano (Italy)
title_sort preliminary indoor radon measurements near faults crossing urban areas of mt. etna volcano (italy)
topic Public Health
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6509806/
https://www.ncbi.nlm.nih.gov/pubmed/31131269
http://dx.doi.org/10.3389/fpubh.2019.00105
work_keys_str_mv AT nerimarco preliminaryindoorradonmeasurementsnearfaultscrossingurbanareasofmtetnavolcanoitaly
AT giammancosalvatore preliminaryindoorradonmeasurementsnearfaultscrossingurbanareasofmtetnavolcanoitaly
AT leonardianna preliminaryindoorradonmeasurementsnearfaultscrossingurbanareasofmtetnavolcanoitaly