An evaluation of superhydrophilic surfaces of dental implants - a systematic review and meta-analysis

BACKGROUND: The characteristics of a dental implant surface have a decisive influence on the process of osseointegration. According to the current state of knowledge, surface modification can not only affect the morphology of cells, and in this way have a positive impact on osseointegration. METHODS...

Descripción completa

Detalles Bibliográficos
Autores principales: Makowiecki, Arkadiusz, Hadzik, Jakub, Błaszczyszyn, Artur, Gedrange, Tomasz, Dominiak, Marzena
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6509828/
https://www.ncbi.nlm.nih.gov/pubmed/31077190
http://dx.doi.org/10.1186/s12903-019-0767-8
_version_ 1783417326328086528
author Makowiecki, Arkadiusz
Hadzik, Jakub
Błaszczyszyn, Artur
Gedrange, Tomasz
Dominiak, Marzena
author_facet Makowiecki, Arkadiusz
Hadzik, Jakub
Błaszczyszyn, Artur
Gedrange, Tomasz
Dominiak, Marzena
author_sort Makowiecki, Arkadiusz
collection PubMed
description BACKGROUND: The characteristics of a dental implant surface have a decisive influence on the process of osseointegration. According to the current state of knowledge, surface modification can not only affect the morphology of cells, and in this way have a positive impact on osseointegration. METHODS: The objective of this study was to compare survival rates and marginal bone loss as well as assess the degree of stability of Straumann SLAactive® and Thomenn Incell® implants with a superhydrophilic surface. Authors present review of data published between 01.01.2008 and 12.31.2016 that was found in PubMed/MEDLINE internet database, An Internet search of databases produced a total of 1230 studies, 20 publications were finally selected for the present study based on the established selection and exclusion criteria. RESULTS: The statistical analysis was performed. A Cumulative Implant Survival Rate (CSR%) was 98.5%, Marginal bone loss (MBL) after 6 months was M = 0.60 mm and 0.6 5 mm after 12 months and secondary stability in a group Thommen implants M = 71.3 ISQ and M = 75.2 ISQ in group of Straumann. CONCLUSION: Despite certain differences in the values of the studied parameters, both of the systems, i.e. Thommen Inicell and Straumann SLActive, demonstrated a high survival rate, a high level of implant stability and low marginal bone loss.
format Online
Article
Text
id pubmed-6509828
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-65098282019-06-05 An evaluation of superhydrophilic surfaces of dental implants - a systematic review and meta-analysis Makowiecki, Arkadiusz Hadzik, Jakub Błaszczyszyn, Artur Gedrange, Tomasz Dominiak, Marzena BMC Oral Health Research Article BACKGROUND: The characteristics of a dental implant surface have a decisive influence on the process of osseointegration. According to the current state of knowledge, surface modification can not only affect the morphology of cells, and in this way have a positive impact on osseointegration. METHODS: The objective of this study was to compare survival rates and marginal bone loss as well as assess the degree of stability of Straumann SLAactive® and Thomenn Incell® implants with a superhydrophilic surface. Authors present review of data published between 01.01.2008 and 12.31.2016 that was found in PubMed/MEDLINE internet database, An Internet search of databases produced a total of 1230 studies, 20 publications were finally selected for the present study based on the established selection and exclusion criteria. RESULTS: The statistical analysis was performed. A Cumulative Implant Survival Rate (CSR%) was 98.5%, Marginal bone loss (MBL) after 6 months was M = 0.60 mm and 0.6 5 mm after 12 months and secondary stability in a group Thommen implants M = 71.3 ISQ and M = 75.2 ISQ in group of Straumann. CONCLUSION: Despite certain differences in the values of the studied parameters, both of the systems, i.e. Thommen Inicell and Straumann SLActive, demonstrated a high survival rate, a high level of implant stability and low marginal bone loss. BioMed Central 2019-05-10 /pmc/articles/PMC6509828/ /pubmed/31077190 http://dx.doi.org/10.1186/s12903-019-0767-8 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Makowiecki, Arkadiusz
Hadzik, Jakub
Błaszczyszyn, Artur
Gedrange, Tomasz
Dominiak, Marzena
An evaluation of superhydrophilic surfaces of dental implants - a systematic review and meta-analysis
title An evaluation of superhydrophilic surfaces of dental implants - a systematic review and meta-analysis
title_full An evaluation of superhydrophilic surfaces of dental implants - a systematic review and meta-analysis
title_fullStr An evaluation of superhydrophilic surfaces of dental implants - a systematic review and meta-analysis
title_full_unstemmed An evaluation of superhydrophilic surfaces of dental implants - a systematic review and meta-analysis
title_short An evaluation of superhydrophilic surfaces of dental implants - a systematic review and meta-analysis
title_sort evaluation of superhydrophilic surfaces of dental implants - a systematic review and meta-analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6509828/
https://www.ncbi.nlm.nih.gov/pubmed/31077190
http://dx.doi.org/10.1186/s12903-019-0767-8
work_keys_str_mv AT makowieckiarkadiusz anevaluationofsuperhydrophilicsurfacesofdentalimplantsasystematicreviewandmetaanalysis
AT hadzikjakub anevaluationofsuperhydrophilicsurfacesofdentalimplantsasystematicreviewandmetaanalysis
AT błaszczyszynartur anevaluationofsuperhydrophilicsurfacesofdentalimplantsasystematicreviewandmetaanalysis
AT gedrangetomasz anevaluationofsuperhydrophilicsurfacesofdentalimplantsasystematicreviewandmetaanalysis
AT dominiakmarzena anevaluationofsuperhydrophilicsurfacesofdentalimplantsasystematicreviewandmetaanalysis
AT makowieckiarkadiusz evaluationofsuperhydrophilicsurfacesofdentalimplantsasystematicreviewandmetaanalysis
AT hadzikjakub evaluationofsuperhydrophilicsurfacesofdentalimplantsasystematicreviewandmetaanalysis
AT błaszczyszynartur evaluationofsuperhydrophilicsurfacesofdentalimplantsasystematicreviewandmetaanalysis
AT gedrangetomasz evaluationofsuperhydrophilicsurfacesofdentalimplantsasystematicreviewandmetaanalysis
AT dominiakmarzena evaluationofsuperhydrophilicsurfacesofdentalimplantsasystematicreviewandmetaanalysis