Cargando…
A comparative evaluation of fracture load of monolithic and bilayered zirconia crowns with and without a cervical collar: an in vitro study
INTRODUCTION: The use of zirconia based all-ceramic restorations are preferred nowadays owing to superior biologic and esthetic properties. However, these restorations have also reported higher incidences of fracture and chipping. The clinical success may be enhanced by optimizing the core design, t...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Iuliu Hatieganu University of Medicine and Pharmacy
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6510367/ https://www.ncbi.nlm.nih.gov/pubmed/31086846 http://dx.doi.org/10.15386/mpr-985 |
_version_ | 1783417410698608640 |
---|---|
author | Saha, Mainak Kanti Bansal, Surbhi Pathak, Vandana Bhardwaj, Shivani Chauhan, Astha Nirwan, Amit Singh |
author_facet | Saha, Mainak Kanti Bansal, Surbhi Pathak, Vandana Bhardwaj, Shivani Chauhan, Astha Nirwan, Amit Singh |
author_sort | Saha, Mainak Kanti |
collection | PubMed |
description | INTRODUCTION: The use of zirconia based all-ceramic restorations are preferred nowadays owing to superior biologic and esthetic properties. However, these restorations have also reported higher incidences of fracture and chipping. The clinical success may be enhanced by optimizing the core design, through the introduction of monolithic zirconia, or the layered crowns can be strengthened by adding the cervical collar to them. OBJECTIVE: This study was performed with the objective to compare and evaluate the fracture load of monolithic and bilayered zirconia crowns with and without a cervical collar. METHODS: A prospective observational study was carried out to compare 45 fabricated zirconia crowns of three different designs on a customized metal mould. The samples were oriented on the metal mould and subjected to confocal microscope for the evaluation of marginal integrity followed by cementing the crown on the metal mould and subjecting it to the universal testing machine for the analysis for the flexural strength. Data were analyzed using one way Anova and t- test for inter and intra groups. The significance level was set at P ≤ 0.05. RESULTS: The monolith zirconia crowns and layered zirconia crowns with cervical collar reported more flexural strength. CONCLUSION: The amount of force required to fracture the zirconia crowns was higher in the case of monolith zirconia crown and layered zirconia crown with cervical collar as compared to the layered zirconia crown without cervical collar. |
format | Online Article Text |
id | pubmed-6510367 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Iuliu Hatieganu University of Medicine and Pharmacy |
record_format | MEDLINE/PubMed |
spelling | pubmed-65103672019-05-13 A comparative evaluation of fracture load of monolithic and bilayered zirconia crowns with and without a cervical collar: an in vitro study Saha, Mainak Kanti Bansal, Surbhi Pathak, Vandana Bhardwaj, Shivani Chauhan, Astha Nirwan, Amit Singh Med Pharm Rep Original Research INTRODUCTION: The use of zirconia based all-ceramic restorations are preferred nowadays owing to superior biologic and esthetic properties. However, these restorations have also reported higher incidences of fracture and chipping. The clinical success may be enhanced by optimizing the core design, through the introduction of monolithic zirconia, or the layered crowns can be strengthened by adding the cervical collar to them. OBJECTIVE: This study was performed with the objective to compare and evaluate the fracture load of monolithic and bilayered zirconia crowns with and without a cervical collar. METHODS: A prospective observational study was carried out to compare 45 fabricated zirconia crowns of three different designs on a customized metal mould. The samples were oriented on the metal mould and subjected to confocal microscope for the evaluation of marginal integrity followed by cementing the crown on the metal mould and subjecting it to the universal testing machine for the analysis for the flexural strength. Data were analyzed using one way Anova and t- test for inter and intra groups. The significance level was set at P ≤ 0.05. RESULTS: The monolith zirconia crowns and layered zirconia crowns with cervical collar reported more flexural strength. CONCLUSION: The amount of force required to fracture the zirconia crowns was higher in the case of monolith zirconia crown and layered zirconia crown with cervical collar as compared to the layered zirconia crown without cervical collar. Iuliu Hatieganu University of Medicine and Pharmacy 2019-04 2019-04-25 /pmc/articles/PMC6510367/ /pubmed/31086846 http://dx.doi.org/10.15386/mpr-985 Text en This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (http://creativecommons.org/licenses/by-nc-nd/4.0/) |
spellingShingle | Original Research Saha, Mainak Kanti Bansal, Surbhi Pathak, Vandana Bhardwaj, Shivani Chauhan, Astha Nirwan, Amit Singh A comparative evaluation of fracture load of monolithic and bilayered zirconia crowns with and without a cervical collar: an in vitro study |
title | A comparative evaluation of fracture load of monolithic and bilayered zirconia crowns with and without a cervical collar: an in vitro study |
title_full | A comparative evaluation of fracture load of monolithic and bilayered zirconia crowns with and without a cervical collar: an in vitro study |
title_fullStr | A comparative evaluation of fracture load of monolithic and bilayered zirconia crowns with and without a cervical collar: an in vitro study |
title_full_unstemmed | A comparative evaluation of fracture load of monolithic and bilayered zirconia crowns with and without a cervical collar: an in vitro study |
title_short | A comparative evaluation of fracture load of monolithic and bilayered zirconia crowns with and without a cervical collar: an in vitro study |
title_sort | comparative evaluation of fracture load of monolithic and bilayered zirconia crowns with and without a cervical collar: an in vitro study |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6510367/ https://www.ncbi.nlm.nih.gov/pubmed/31086846 http://dx.doi.org/10.15386/mpr-985 |
work_keys_str_mv | AT sahamainakkanti acomparativeevaluationoffractureloadofmonolithicandbilayeredzirconiacrownswithandwithoutacervicalcollaraninvitrostudy AT bansalsurbhi acomparativeevaluationoffractureloadofmonolithicandbilayeredzirconiacrownswithandwithoutacervicalcollaraninvitrostudy AT pathakvandana acomparativeevaluationoffractureloadofmonolithicandbilayeredzirconiacrownswithandwithoutacervicalcollaraninvitrostudy AT bhardwajshivani acomparativeevaluationoffractureloadofmonolithicandbilayeredzirconiacrownswithandwithoutacervicalcollaraninvitrostudy AT chauhanastha acomparativeevaluationoffractureloadofmonolithicandbilayeredzirconiacrownswithandwithoutacervicalcollaraninvitrostudy AT nirwanamitsingh acomparativeevaluationoffractureloadofmonolithicandbilayeredzirconiacrownswithandwithoutacervicalcollaraninvitrostudy AT sahamainakkanti comparativeevaluationoffractureloadofmonolithicandbilayeredzirconiacrownswithandwithoutacervicalcollaraninvitrostudy AT bansalsurbhi comparativeevaluationoffractureloadofmonolithicandbilayeredzirconiacrownswithandwithoutacervicalcollaraninvitrostudy AT pathakvandana comparativeevaluationoffractureloadofmonolithicandbilayeredzirconiacrownswithandwithoutacervicalcollaraninvitrostudy AT bhardwajshivani comparativeevaluationoffractureloadofmonolithicandbilayeredzirconiacrownswithandwithoutacervicalcollaraninvitrostudy AT chauhanastha comparativeevaluationoffractureloadofmonolithicandbilayeredzirconiacrownswithandwithoutacervicalcollaraninvitrostudy AT nirwanamitsingh comparativeevaluationoffractureloadofmonolithicandbilayeredzirconiacrownswithandwithoutacervicalcollaraninvitrostudy |