Cargando…
Multiparametric whole-body 3.0-T MRI in newly diagnosed intermediate- and high-risk prostate cancer: diagnostic accuracy and interobserver agreement for nodal and metastatic staging
OBJECTIVES: To determine the diagnostic accuracy and interobserver concordance of whole-body (WB)-MRI, vs. (99m)Tc bone scintigraphy (BS) and (18)fluoro-ethyl-choline ((18)F-choline) PET/CT for the primary staging of intermediate/high-risk prostate cancer. METHODS: An institutional review board appr...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6510859/ https://www.ncbi.nlm.nih.gov/pubmed/30519933 http://dx.doi.org/10.1007/s00330-018-5813-4 |
_version_ | 1783417484557156352 |
---|---|
author | Johnston, Edward William Latifoltojar, Arash Sidhu, Harbir Singh Ramachandran, Navin Sokolska, Magdalena Bainbridge, Alan Moore, Caroline Ahmed, Hashim Uddin Punwani, Shonit |
author_facet | Johnston, Edward William Latifoltojar, Arash Sidhu, Harbir Singh Ramachandran, Navin Sokolska, Magdalena Bainbridge, Alan Moore, Caroline Ahmed, Hashim Uddin Punwani, Shonit |
author_sort | Johnston, Edward William |
collection | PubMed |
description | OBJECTIVES: To determine the diagnostic accuracy and interobserver concordance of whole-body (WB)-MRI, vs. (99m)Tc bone scintigraphy (BS) and (18)fluoro-ethyl-choline ((18)F-choline) PET/CT for the primary staging of intermediate/high-risk prostate cancer. METHODS: An institutional review board approved prospective cohort study carried out between July 2012 and November 2015, whereby 56 men prospectively underwent 3.0-T multiparametric (mp)-WB-MRI in addition to BS (all patients) ± (18)F-choline PET/CT (33 patients). MRI comprised pre- and post-contrast modified Dixon (mDixon), T2-weighted (T2W) imaging, and diffusion-weighted imaging (DWI). Patients underwent follow-up mp-WB-MRI at 1 year to derive the reference standard. WB-MRIs were reviewed by two radiologists applying a 6-point scale and a locked sequential read (LSR) paradigm for the suspicion of nodal (N) and metastatic disease (M1a and M1b). RESULTS: The mean sensitivity/specificity of WB-MRI for N1 disease was 1.00/0.96 respectively, compared with 1.00/0.82 for (18)F-choline PET/CT. The mean sensitivity and specificity of WB-MRI, (18)F-choline PET/CT, and BS were 0.90/0.88, 0.80/0.92, and 0.60/1.00 for M1b disease. ROC-AUC did not show statistically significant improvement for each component of the LSR; mean ROC-AUC 0.92, 0.94, and 0.93 (p < 0.05) for mDixon + DWI, + T2WI, and + contrast respectively. WB-MRI had an interobserver concordance (κ) of 0.79, 0.68, and 0.58 for N1, M1a, and M1b diseases respectively. CONCLUSIONS: WB-MRI provides high levels of diagnostic accuracy for both nodal and metastatic bone disease, with higher levels of sensitivity than BS for metastatic disease, and similar performance to (18)F-choline PET/CT. T2 and post-contrast mDixon had no significant additive value above a protocol comprising mDixon and DWI alone. KEY POINTS: • A whole-body MRI protocol comprising unenhanced mDixon and diffusion-weighted imaging provides high levels of diagnostic accuracy for the primary staging of intermediate- and high-risk prostate cancer. • The diagnostic accuracy of whole-body MRI is much higher than that of bone scintigraphy, as currently recommended for clinical use. • Staging using WB-MRI, rather than bone scintigraphy, could result in better patient stratification and treatment delivery than is currently provided to patients worldwide. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00330-018-5813-4) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-6510859 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-65108592019-05-28 Multiparametric whole-body 3.0-T MRI in newly diagnosed intermediate- and high-risk prostate cancer: diagnostic accuracy and interobserver agreement for nodal and metastatic staging Johnston, Edward William Latifoltojar, Arash Sidhu, Harbir Singh Ramachandran, Navin Sokolska, Magdalena Bainbridge, Alan Moore, Caroline Ahmed, Hashim Uddin Punwani, Shonit Eur Radiol Oncology OBJECTIVES: To determine the diagnostic accuracy and interobserver concordance of whole-body (WB)-MRI, vs. (99m)Tc bone scintigraphy (BS) and (18)fluoro-ethyl-choline ((18)F-choline) PET/CT for the primary staging of intermediate/high-risk prostate cancer. METHODS: An institutional review board approved prospective cohort study carried out between July 2012 and November 2015, whereby 56 men prospectively underwent 3.0-T multiparametric (mp)-WB-MRI in addition to BS (all patients) ± (18)F-choline PET/CT (33 patients). MRI comprised pre- and post-contrast modified Dixon (mDixon), T2-weighted (T2W) imaging, and diffusion-weighted imaging (DWI). Patients underwent follow-up mp-WB-MRI at 1 year to derive the reference standard. WB-MRIs were reviewed by two radiologists applying a 6-point scale and a locked sequential read (LSR) paradigm for the suspicion of nodal (N) and metastatic disease (M1a and M1b). RESULTS: The mean sensitivity/specificity of WB-MRI for N1 disease was 1.00/0.96 respectively, compared with 1.00/0.82 for (18)F-choline PET/CT. The mean sensitivity and specificity of WB-MRI, (18)F-choline PET/CT, and BS were 0.90/0.88, 0.80/0.92, and 0.60/1.00 for M1b disease. ROC-AUC did not show statistically significant improvement for each component of the LSR; mean ROC-AUC 0.92, 0.94, and 0.93 (p < 0.05) for mDixon + DWI, + T2WI, and + contrast respectively. WB-MRI had an interobserver concordance (κ) of 0.79, 0.68, and 0.58 for N1, M1a, and M1b diseases respectively. CONCLUSIONS: WB-MRI provides high levels of diagnostic accuracy for both nodal and metastatic bone disease, with higher levels of sensitivity than BS for metastatic disease, and similar performance to (18)F-choline PET/CT. T2 and post-contrast mDixon had no significant additive value above a protocol comprising mDixon and DWI alone. KEY POINTS: • A whole-body MRI protocol comprising unenhanced mDixon and diffusion-weighted imaging provides high levels of diagnostic accuracy for the primary staging of intermediate- and high-risk prostate cancer. • The diagnostic accuracy of whole-body MRI is much higher than that of bone scintigraphy, as currently recommended for clinical use. • Staging using WB-MRI, rather than bone scintigraphy, could result in better patient stratification and treatment delivery than is currently provided to patients worldwide. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00330-018-5813-4) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2018-12-05 2019 /pmc/articles/PMC6510859/ /pubmed/30519933 http://dx.doi.org/10.1007/s00330-018-5813-4 Text en © The Author(s) 2018 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Oncology Johnston, Edward William Latifoltojar, Arash Sidhu, Harbir Singh Ramachandran, Navin Sokolska, Magdalena Bainbridge, Alan Moore, Caroline Ahmed, Hashim Uddin Punwani, Shonit Multiparametric whole-body 3.0-T MRI in newly diagnosed intermediate- and high-risk prostate cancer: diagnostic accuracy and interobserver agreement for nodal and metastatic staging |
title | Multiparametric whole-body 3.0-T MRI in newly diagnosed intermediate- and high-risk prostate cancer: diagnostic accuracy and interobserver agreement for nodal and metastatic staging |
title_full | Multiparametric whole-body 3.0-T MRI in newly diagnosed intermediate- and high-risk prostate cancer: diagnostic accuracy and interobserver agreement for nodal and metastatic staging |
title_fullStr | Multiparametric whole-body 3.0-T MRI in newly diagnosed intermediate- and high-risk prostate cancer: diagnostic accuracy and interobserver agreement for nodal and metastatic staging |
title_full_unstemmed | Multiparametric whole-body 3.0-T MRI in newly diagnosed intermediate- and high-risk prostate cancer: diagnostic accuracy and interobserver agreement for nodal and metastatic staging |
title_short | Multiparametric whole-body 3.0-T MRI in newly diagnosed intermediate- and high-risk prostate cancer: diagnostic accuracy and interobserver agreement for nodal and metastatic staging |
title_sort | multiparametric whole-body 3.0-t mri in newly diagnosed intermediate- and high-risk prostate cancer: diagnostic accuracy and interobserver agreement for nodal and metastatic staging |
topic | Oncology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6510859/ https://www.ncbi.nlm.nih.gov/pubmed/30519933 http://dx.doi.org/10.1007/s00330-018-5813-4 |
work_keys_str_mv | AT johnstonedwardwilliam multiparametricwholebody30tmriinnewlydiagnosedintermediateandhighriskprostatecancerdiagnosticaccuracyandinterobserveragreementfornodalandmetastaticstaging AT latifoltojararash multiparametricwholebody30tmriinnewlydiagnosedintermediateandhighriskprostatecancerdiagnosticaccuracyandinterobserveragreementfornodalandmetastaticstaging AT sidhuharbirsingh multiparametricwholebody30tmriinnewlydiagnosedintermediateandhighriskprostatecancerdiagnosticaccuracyandinterobserveragreementfornodalandmetastaticstaging AT ramachandrannavin multiparametricwholebody30tmriinnewlydiagnosedintermediateandhighriskprostatecancerdiagnosticaccuracyandinterobserveragreementfornodalandmetastaticstaging AT sokolskamagdalena multiparametricwholebody30tmriinnewlydiagnosedintermediateandhighriskprostatecancerdiagnosticaccuracyandinterobserveragreementfornodalandmetastaticstaging AT bainbridgealan multiparametricwholebody30tmriinnewlydiagnosedintermediateandhighriskprostatecancerdiagnosticaccuracyandinterobserveragreementfornodalandmetastaticstaging AT moorecaroline multiparametricwholebody30tmriinnewlydiagnosedintermediateandhighriskprostatecancerdiagnosticaccuracyandinterobserveragreementfornodalandmetastaticstaging AT ahmedhashimuddin multiparametricwholebody30tmriinnewlydiagnosedintermediateandhighriskprostatecancerdiagnosticaccuracyandinterobserveragreementfornodalandmetastaticstaging AT punwanishonit multiparametricwholebody30tmriinnewlydiagnosedintermediateandhighriskprostatecancerdiagnosticaccuracyandinterobserveragreementfornodalandmetastaticstaging |