Cargando…

Transcatheter aortic valve replacement alters ascending aortic blood flow and wall shear stress patterns: A 4D flow MRI comparison with age-matched, elderly controls

BACKGROUND: With the implementation of transcatheter aortic valve replacement (TAVR) in lower-risk patients, evaluation of blood flow characteristics and the effect of TAVR on aortic dilatation becomes of considerable interest. We employed 4D flow MRI in the ascending aorta of patients after TAVR to...

Descripción completa

Detalles Bibliográficos
Autores principales: Farag, E. S., Vendrik, J., van Ooij, P., Poortvliet, Q. L., van Kesteren, F., Wollersheim, L. W., Kaya, A., Driessen, A. H. G., Piek, J. J., Koch, K. T., Baan, J., Planken, R. N., Kluin, J., Nederveen, A. J., de Mol, B. A. J. M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6510864/
https://www.ncbi.nlm.nih.gov/pubmed/30132105
http://dx.doi.org/10.1007/s00330-018-5672-z
_version_ 1783417485699055616
author Farag, E. S.
Vendrik, J.
van Ooij, P.
Poortvliet, Q. L.
van Kesteren, F.
Wollersheim, L. W.
Kaya, A.
Driessen, A. H. G.
Piek, J. J.
Koch, K. T.
Baan, J.
Planken, R. N.
Kluin, J.
Nederveen, A. J.
de Mol, B. A. J. M.
author_facet Farag, E. S.
Vendrik, J.
van Ooij, P.
Poortvliet, Q. L.
van Kesteren, F.
Wollersheim, L. W.
Kaya, A.
Driessen, A. H. G.
Piek, J. J.
Koch, K. T.
Baan, J.
Planken, R. N.
Kluin, J.
Nederveen, A. J.
de Mol, B. A. J. M.
author_sort Farag, E. S.
collection PubMed
description BACKGROUND: With the implementation of transcatheter aortic valve replacement (TAVR) in lower-risk patients, evaluation of blood flow characteristics and the effect of TAVR on aortic dilatation becomes of considerable interest. We employed 4D flow MRI in the ascending aorta of patients after TAVR to assess wall shear stress (WSS) and compare blood flow patterns with surgical aortic valve replacement (SAVR) and age- and gender-matched controls. METHODS: Fourteen post-TAVR patients and ten age- and gender-matched controls underwent kt-PCA accelerated 4D flow MRI of the thoracic aorta at 3.0 Tesla. Velocity and wall shear stress was compared between the two groups. In addition, aortic flow eccentricity and displacement was assessed and compared between TAVR patients, controls and 14 SAVR patients recruited as part of an earlier study. RESULTS: Compared to controls, abnormally elevated WSS was present in 30±10% of the ascending aortic wall in TAVR patients. Increased WSS was present along the posterior mid-ascending aorta and the anterior distal-ascending aorta in all TAVR patients. TAVR results in eccentric and displaced flow in the mid- and distal-ascending aorta, whereas blood flow displacement in SAVR patients occurs only in the distal-ascending aorta. CONCLUSION: This study shows that TAVR results in increased blood flow velocity and WSS in the ascending aorta compared to age- and gender-matched elderly controls. This finding warrants longitudinal assessment of aortic dilatation after TAVR in the era of potential TAVR in lower-risk patients. Additionally, TAVR results in altered blood flow eccentricity and displacement in the mid- and distal-ascending aorta, whereas SAVR only results in altered blood flow eccentricity and displacement in the distal-ascending aorta. KEY POINTS: • TAVR results in increased blood flow velocity and WSS in the ascending aorta. • Longitudinal assessment of aortic dilatation after TAVR is warranted in the era of potential TAVR in lower-risk patients. • Both TAVR and SAVR result in altered blood flow patterns in the ascending aorta when compared to age-matched controls.
format Online
Article
Text
id pubmed-6510864
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-65108642019-05-28 Transcatheter aortic valve replacement alters ascending aortic blood flow and wall shear stress patterns: A 4D flow MRI comparison with age-matched, elderly controls Farag, E. S. Vendrik, J. van Ooij, P. Poortvliet, Q. L. van Kesteren, F. Wollersheim, L. W. Kaya, A. Driessen, A. H. G. Piek, J. J. Koch, K. T. Baan, J. Planken, R. N. Kluin, J. Nederveen, A. J. de Mol, B. A. J. M. Eur Radiol Magnetic Resonance BACKGROUND: With the implementation of transcatheter aortic valve replacement (TAVR) in lower-risk patients, evaluation of blood flow characteristics and the effect of TAVR on aortic dilatation becomes of considerable interest. We employed 4D flow MRI in the ascending aorta of patients after TAVR to assess wall shear stress (WSS) and compare blood flow patterns with surgical aortic valve replacement (SAVR) and age- and gender-matched controls. METHODS: Fourteen post-TAVR patients and ten age- and gender-matched controls underwent kt-PCA accelerated 4D flow MRI of the thoracic aorta at 3.0 Tesla. Velocity and wall shear stress was compared between the two groups. In addition, aortic flow eccentricity and displacement was assessed and compared between TAVR patients, controls and 14 SAVR patients recruited as part of an earlier study. RESULTS: Compared to controls, abnormally elevated WSS was present in 30±10% of the ascending aortic wall in TAVR patients. Increased WSS was present along the posterior mid-ascending aorta and the anterior distal-ascending aorta in all TAVR patients. TAVR results in eccentric and displaced flow in the mid- and distal-ascending aorta, whereas blood flow displacement in SAVR patients occurs only in the distal-ascending aorta. CONCLUSION: This study shows that TAVR results in increased blood flow velocity and WSS in the ascending aorta compared to age- and gender-matched elderly controls. This finding warrants longitudinal assessment of aortic dilatation after TAVR in the era of potential TAVR in lower-risk patients. Additionally, TAVR results in altered blood flow eccentricity and displacement in the mid- and distal-ascending aorta, whereas SAVR only results in altered blood flow eccentricity and displacement in the distal-ascending aorta. KEY POINTS: • TAVR results in increased blood flow velocity and WSS in the ascending aorta. • Longitudinal assessment of aortic dilatation after TAVR is warranted in the era of potential TAVR in lower-risk patients. • Both TAVR and SAVR result in altered blood flow patterns in the ascending aorta when compared to age-matched controls. Springer Berlin Heidelberg 2018-08-21 2019 /pmc/articles/PMC6510864/ /pubmed/30132105 http://dx.doi.org/10.1007/s00330-018-5672-z Text en © The Author(s) 2018 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Magnetic Resonance
Farag, E. S.
Vendrik, J.
van Ooij, P.
Poortvliet, Q. L.
van Kesteren, F.
Wollersheim, L. W.
Kaya, A.
Driessen, A. H. G.
Piek, J. J.
Koch, K. T.
Baan, J.
Planken, R. N.
Kluin, J.
Nederveen, A. J.
de Mol, B. A. J. M.
Transcatheter aortic valve replacement alters ascending aortic blood flow and wall shear stress patterns: A 4D flow MRI comparison with age-matched, elderly controls
title Transcatheter aortic valve replacement alters ascending aortic blood flow and wall shear stress patterns: A 4D flow MRI comparison with age-matched, elderly controls
title_full Transcatheter aortic valve replacement alters ascending aortic blood flow and wall shear stress patterns: A 4D flow MRI comparison with age-matched, elderly controls
title_fullStr Transcatheter aortic valve replacement alters ascending aortic blood flow and wall shear stress patterns: A 4D flow MRI comparison with age-matched, elderly controls
title_full_unstemmed Transcatheter aortic valve replacement alters ascending aortic blood flow and wall shear stress patterns: A 4D flow MRI comparison with age-matched, elderly controls
title_short Transcatheter aortic valve replacement alters ascending aortic blood flow and wall shear stress patterns: A 4D flow MRI comparison with age-matched, elderly controls
title_sort transcatheter aortic valve replacement alters ascending aortic blood flow and wall shear stress patterns: a 4d flow mri comparison with age-matched, elderly controls
topic Magnetic Resonance
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6510864/
https://www.ncbi.nlm.nih.gov/pubmed/30132105
http://dx.doi.org/10.1007/s00330-018-5672-z
work_keys_str_mv AT farages transcatheteraorticvalvereplacementaltersascendingaorticbloodflowandwallshearstresspatternsa4dflowmricomparisonwithagematchedelderlycontrols
AT vendrikj transcatheteraorticvalvereplacementaltersascendingaorticbloodflowandwallshearstresspatternsa4dflowmricomparisonwithagematchedelderlycontrols
AT vanooijp transcatheteraorticvalvereplacementaltersascendingaorticbloodflowandwallshearstresspatternsa4dflowmricomparisonwithagematchedelderlycontrols
AT poortvlietql transcatheteraorticvalvereplacementaltersascendingaorticbloodflowandwallshearstresspatternsa4dflowmricomparisonwithagematchedelderlycontrols
AT vankesterenf transcatheteraorticvalvereplacementaltersascendingaorticbloodflowandwallshearstresspatternsa4dflowmricomparisonwithagematchedelderlycontrols
AT wollersheimlw transcatheteraorticvalvereplacementaltersascendingaorticbloodflowandwallshearstresspatternsa4dflowmricomparisonwithagematchedelderlycontrols
AT kayaa transcatheteraorticvalvereplacementaltersascendingaorticbloodflowandwallshearstresspatternsa4dflowmricomparisonwithagematchedelderlycontrols
AT driessenahg transcatheteraorticvalvereplacementaltersascendingaorticbloodflowandwallshearstresspatternsa4dflowmricomparisonwithagematchedelderlycontrols
AT piekjj transcatheteraorticvalvereplacementaltersascendingaorticbloodflowandwallshearstresspatternsa4dflowmricomparisonwithagematchedelderlycontrols
AT kochkt transcatheteraorticvalvereplacementaltersascendingaorticbloodflowandwallshearstresspatternsa4dflowmricomparisonwithagematchedelderlycontrols
AT baanj transcatheteraorticvalvereplacementaltersascendingaorticbloodflowandwallshearstresspatternsa4dflowmricomparisonwithagematchedelderlycontrols
AT plankenrn transcatheteraorticvalvereplacementaltersascendingaorticbloodflowandwallshearstresspatternsa4dflowmricomparisonwithagematchedelderlycontrols
AT kluinj transcatheteraorticvalvereplacementaltersascendingaorticbloodflowandwallshearstresspatternsa4dflowmricomparisonwithagematchedelderlycontrols
AT nederveenaj transcatheteraorticvalvereplacementaltersascendingaorticbloodflowandwallshearstresspatternsa4dflowmricomparisonwithagematchedelderlycontrols
AT demolbajm transcatheteraorticvalvereplacementaltersascendingaorticbloodflowandwallshearstresspatternsa4dflowmricomparisonwithagematchedelderlycontrols