Cargando…
Developing a Quantitative Ultrasound Image Feature Analysis Scheme to Assess Tumor Treatment Efficacy Using a Mouse Model
The aim of this study is to investigate the feasibility of identifying and applying quantitative imaging features computed from ultrasound images of athymic nude mice to predict tumor response to treatment at an early stage. A computer-aided detection (CAD) scheme with a graphic user interface was d...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6513863/ https://www.ncbi.nlm.nih.gov/pubmed/31086267 http://dx.doi.org/10.1038/s41598-019-43847-7 |
_version_ | 1783417778681675776 |
---|---|
author | Mirniaharikandehei, Seyedehnafiseh VanOsdol, Joshua Heidari, Morteza Danala, Gopichandh Sethuraman, Sri Nandhini Ranjan, Ashish Zheng, Bin |
author_facet | Mirniaharikandehei, Seyedehnafiseh VanOsdol, Joshua Heidari, Morteza Danala, Gopichandh Sethuraman, Sri Nandhini Ranjan, Ashish Zheng, Bin |
author_sort | Mirniaharikandehei, Seyedehnafiseh |
collection | PubMed |
description | The aim of this study is to investigate the feasibility of identifying and applying quantitative imaging features computed from ultrasound images of athymic nude mice to predict tumor response to treatment at an early stage. A computer-aided detection (CAD) scheme with a graphic user interface was developed to conduct tumor segmentation and image feature analysis. A dataset involving ultrasound images of 23 athymic nude mice bearing C26 mouse adenocarcinomas was assembled. These mice were divided into 7 treatment groups utilizing a combination of thermal and nanoparticle-controlled drug delivery. Longitudinal ultrasound images of mice were taken prior and post-treatment in day 3 and day 6. After tumor segmentation, CAD scheme computed image features and created four feature pools including features computed from (1) prior treatment images only and (2) difference between prior and post-treatment images of day 3 and day 6, respectively. To predict tumor treatment efficacy, data analysis was performed to identify top image features and an optimal feature fusion method, which have a higher correlation to tumor size increase ratio (TSIR) determined at Day 10. Using image features computed from day 3, the highest Pearson Correlation coefficients between the top two features selected from two feature pools versus TSIR were 0.373 and 0.552, respectively. Using an equally weighted fusion method of two features computed from prior and post-treatment images, the correlation coefficient increased to 0.679. Meanwhile, using image features computed from day 6, the highest correlation coefficient was 0.680. Study demonstrated the feasibility of extracting quantitative image features from the ultrasound images taken at an early treatment stage to predict tumor response to therapies. |
format | Online Article Text |
id | pubmed-6513863 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-65138632019-05-24 Developing a Quantitative Ultrasound Image Feature Analysis Scheme to Assess Tumor Treatment Efficacy Using a Mouse Model Mirniaharikandehei, Seyedehnafiseh VanOsdol, Joshua Heidari, Morteza Danala, Gopichandh Sethuraman, Sri Nandhini Ranjan, Ashish Zheng, Bin Sci Rep Article The aim of this study is to investigate the feasibility of identifying and applying quantitative imaging features computed from ultrasound images of athymic nude mice to predict tumor response to treatment at an early stage. A computer-aided detection (CAD) scheme with a graphic user interface was developed to conduct tumor segmentation and image feature analysis. A dataset involving ultrasound images of 23 athymic nude mice bearing C26 mouse adenocarcinomas was assembled. These mice were divided into 7 treatment groups utilizing a combination of thermal and nanoparticle-controlled drug delivery. Longitudinal ultrasound images of mice were taken prior and post-treatment in day 3 and day 6. After tumor segmentation, CAD scheme computed image features and created four feature pools including features computed from (1) prior treatment images only and (2) difference between prior and post-treatment images of day 3 and day 6, respectively. To predict tumor treatment efficacy, data analysis was performed to identify top image features and an optimal feature fusion method, which have a higher correlation to tumor size increase ratio (TSIR) determined at Day 10. Using image features computed from day 3, the highest Pearson Correlation coefficients between the top two features selected from two feature pools versus TSIR were 0.373 and 0.552, respectively. Using an equally weighted fusion method of two features computed from prior and post-treatment images, the correlation coefficient increased to 0.679. Meanwhile, using image features computed from day 6, the highest correlation coefficient was 0.680. Study demonstrated the feasibility of extracting quantitative image features from the ultrasound images taken at an early treatment stage to predict tumor response to therapies. Nature Publishing Group UK 2019-05-13 /pmc/articles/PMC6513863/ /pubmed/31086267 http://dx.doi.org/10.1038/s41598-019-43847-7 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Mirniaharikandehei, Seyedehnafiseh VanOsdol, Joshua Heidari, Morteza Danala, Gopichandh Sethuraman, Sri Nandhini Ranjan, Ashish Zheng, Bin Developing a Quantitative Ultrasound Image Feature Analysis Scheme to Assess Tumor Treatment Efficacy Using a Mouse Model |
title | Developing a Quantitative Ultrasound Image Feature Analysis Scheme to Assess Tumor Treatment Efficacy Using a Mouse Model |
title_full | Developing a Quantitative Ultrasound Image Feature Analysis Scheme to Assess Tumor Treatment Efficacy Using a Mouse Model |
title_fullStr | Developing a Quantitative Ultrasound Image Feature Analysis Scheme to Assess Tumor Treatment Efficacy Using a Mouse Model |
title_full_unstemmed | Developing a Quantitative Ultrasound Image Feature Analysis Scheme to Assess Tumor Treatment Efficacy Using a Mouse Model |
title_short | Developing a Quantitative Ultrasound Image Feature Analysis Scheme to Assess Tumor Treatment Efficacy Using a Mouse Model |
title_sort | developing a quantitative ultrasound image feature analysis scheme to assess tumor treatment efficacy using a mouse model |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6513863/ https://www.ncbi.nlm.nih.gov/pubmed/31086267 http://dx.doi.org/10.1038/s41598-019-43847-7 |
work_keys_str_mv | AT mirniaharikandeheiseyedehnafiseh developingaquantitativeultrasoundimagefeatureanalysisschemetoassesstumortreatmentefficacyusingamousemodel AT vanosdoljoshua developingaquantitativeultrasoundimagefeatureanalysisschemetoassesstumortreatmentefficacyusingamousemodel AT heidarimorteza developingaquantitativeultrasoundimagefeatureanalysisschemetoassesstumortreatmentefficacyusingamousemodel AT danalagopichandh developingaquantitativeultrasoundimagefeatureanalysisschemetoassesstumortreatmentefficacyusingamousemodel AT sethuramansrinandhini developingaquantitativeultrasoundimagefeatureanalysisschemetoassesstumortreatmentefficacyusingamousemodel AT ranjanashish developingaquantitativeultrasoundimagefeatureanalysisschemetoassesstumortreatmentefficacyusingamousemodel AT zhengbin developingaquantitativeultrasoundimagefeatureanalysisschemetoassesstumortreatmentefficacyusingamousemodel |