Assessment of Shoulder Range of Motion Using a Wireless Inertial Motion Capture Device—A Validation Study

(1) Background: Measuring joint range of motion has traditionally occurred with a universal goniometer or expensive laboratory based kinematic analysis systems. Technological advances in wearable inertial measurement units (IMU) enables limb motion to be measured with a small portable electronic dev...

Descripción completa

Detalles Bibliográficos
Autores principales: Rigoni, Michael, Gill, Stephen, Babazadeh, Sina, Elsewaisy, Osama, Gillies, Hugh, Nguyen, Nhan, Pathirana, Pubudu N., Page, Richard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6514956/
https://www.ncbi.nlm.nih.gov/pubmed/31013931
http://dx.doi.org/10.3390/s19081781
_version_ 1783417980707667968
author Rigoni, Michael
Gill, Stephen
Babazadeh, Sina
Elsewaisy, Osama
Gillies, Hugh
Nguyen, Nhan
Pathirana, Pubudu N.
Page, Richard
author_facet Rigoni, Michael
Gill, Stephen
Babazadeh, Sina
Elsewaisy, Osama
Gillies, Hugh
Nguyen, Nhan
Pathirana, Pubudu N.
Page, Richard
author_sort Rigoni, Michael
collection PubMed
description (1) Background: Measuring joint range of motion has traditionally occurred with a universal goniometer or expensive laboratory based kinematic analysis systems. Technological advances in wearable inertial measurement units (IMU) enables limb motion to be measured with a small portable electronic device. This paper aims to validate an IMU, the ‘Biokin’, for measuring shoulder range of motion in healthy adults; (2) Methods: Thirty participants completed four shoulder movements (forward flexion, abduction, and internal and external rotation) on each shoulder. Each movement was assessed with a goniometer and the IMU by two testers independently. The extent of agreement between each tester’s goniometer and IMU measurements was assessed with intra-class correlation coefficients (ICC) and Bland-Altman 95% limits of agreement (LOA). Secondary analysis compared agreement between tester’s goniometer or IMU measurements (inter-rater reliability) using ICC’s and LOA; (3) Results: Goniometer and IMU measurements for all movements showed high levels of agreement when taken by the same tester; ICCs > 0.90 and LOAs < ±5 degrees. Inter-rater reliability was lower; ICCs ranged between 0.71 to 0.89 and LOAs were outside a prior defined acceptable LOAs (i.e., > ±5 degrees); (4) Conclusions: The current study provides preliminary evidence of the concurrent validity of the Biokin IMU for assessing shoulder movements, but only when a single tester took measurements. Further testing of the Biokin’s psychometric properties is required before it can be confidently used in routine clinical practice and research settings.
format Online
Article
Text
id pubmed-6514956
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-65149562019-05-30 Assessment of Shoulder Range of Motion Using a Wireless Inertial Motion Capture Device—A Validation Study Rigoni, Michael Gill, Stephen Babazadeh, Sina Elsewaisy, Osama Gillies, Hugh Nguyen, Nhan Pathirana, Pubudu N. Page, Richard Sensors (Basel) Article (1) Background: Measuring joint range of motion has traditionally occurred with a universal goniometer or expensive laboratory based kinematic analysis systems. Technological advances in wearable inertial measurement units (IMU) enables limb motion to be measured with a small portable electronic device. This paper aims to validate an IMU, the ‘Biokin’, for measuring shoulder range of motion in healthy adults; (2) Methods: Thirty participants completed four shoulder movements (forward flexion, abduction, and internal and external rotation) on each shoulder. Each movement was assessed with a goniometer and the IMU by two testers independently. The extent of agreement between each tester’s goniometer and IMU measurements was assessed with intra-class correlation coefficients (ICC) and Bland-Altman 95% limits of agreement (LOA). Secondary analysis compared agreement between tester’s goniometer or IMU measurements (inter-rater reliability) using ICC’s and LOA; (3) Results: Goniometer and IMU measurements for all movements showed high levels of agreement when taken by the same tester; ICCs > 0.90 and LOAs < ±5 degrees. Inter-rater reliability was lower; ICCs ranged between 0.71 to 0.89 and LOAs were outside a prior defined acceptable LOAs (i.e., > ±5 degrees); (4) Conclusions: The current study provides preliminary evidence of the concurrent validity of the Biokin IMU for assessing shoulder movements, but only when a single tester took measurements. Further testing of the Biokin’s psychometric properties is required before it can be confidently used in routine clinical practice and research settings. MDPI 2019-04-13 /pmc/articles/PMC6514956/ /pubmed/31013931 http://dx.doi.org/10.3390/s19081781 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Rigoni, Michael
Gill, Stephen
Babazadeh, Sina
Elsewaisy, Osama
Gillies, Hugh
Nguyen, Nhan
Pathirana, Pubudu N.
Page, Richard
Assessment of Shoulder Range of Motion Using a Wireless Inertial Motion Capture Device—A Validation Study
title Assessment of Shoulder Range of Motion Using a Wireless Inertial Motion Capture Device—A Validation Study
title_full Assessment of Shoulder Range of Motion Using a Wireless Inertial Motion Capture Device—A Validation Study
title_fullStr Assessment of Shoulder Range of Motion Using a Wireless Inertial Motion Capture Device—A Validation Study
title_full_unstemmed Assessment of Shoulder Range of Motion Using a Wireless Inertial Motion Capture Device—A Validation Study
title_short Assessment of Shoulder Range of Motion Using a Wireless Inertial Motion Capture Device—A Validation Study
title_sort assessment of shoulder range of motion using a wireless inertial motion capture device—a validation study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6514956/
https://www.ncbi.nlm.nih.gov/pubmed/31013931
http://dx.doi.org/10.3390/s19081781
work_keys_str_mv AT rigonimichael assessmentofshoulderrangeofmotionusingawirelessinertialmotioncapturedeviceavalidationstudy
AT gillstephen assessmentofshoulderrangeofmotionusingawirelessinertialmotioncapturedeviceavalidationstudy
AT babazadehsina assessmentofshoulderrangeofmotionusingawirelessinertialmotioncapturedeviceavalidationstudy
AT elsewaisyosama assessmentofshoulderrangeofmotionusingawirelessinertialmotioncapturedeviceavalidationstudy
AT gillieshugh assessmentofshoulderrangeofmotionusingawirelessinertialmotioncapturedeviceavalidationstudy
AT nguyennhan assessmentofshoulderrangeofmotionusingawirelessinertialmotioncapturedeviceavalidationstudy
AT pathiranapubudun assessmentofshoulderrangeofmotionusingawirelessinertialmotioncapturedeviceavalidationstudy
AT pagerichard assessmentofshoulderrangeofmotionusingawirelessinertialmotioncapturedeviceavalidationstudy