Cargando…

Signal in Space Error and Ephemeris Validity Time Evaluation of Milena and Doresa Galileo Satellites †

In August 2016, Milena (E14) and Doresa (E18) satellites started to broadcast ephemeris in navigation message for testing purposes. If these satellites could be used, an improvement in the position accuracy would be achieved. A small error in the ephemeris would impact the accuracy of positioning up...

Descripción completa

Detalles Bibliográficos
Autores principales: Robustelli, Umberto, Benassai, Guido, Pugliano, Giovanni
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6515225/
https://www.ncbi.nlm.nih.gov/pubmed/31013977
http://dx.doi.org/10.3390/s19081786
_version_ 1783418042389102592
author Robustelli, Umberto
Benassai, Guido
Pugliano, Giovanni
author_facet Robustelli, Umberto
Benassai, Guido
Pugliano, Giovanni
author_sort Robustelli, Umberto
collection PubMed
description In August 2016, Milena (E14) and Doresa (E18) satellites started to broadcast ephemeris in navigation message for testing purposes. If these satellites could be used, an improvement in the position accuracy would be achieved. A small error in the ephemeris would impact the accuracy of positioning up to ±2.5 m, thus orbit error must be assessed. The ephemeris quality was evaluated by calculating the SISE(orbit) (in orbit Signal In Space Error) using six different ephemeris validity time thresholds (14,400 s, 10,800 s, 7200 s, 3600 s, 1800 s, and 900 s). Two different periods of 2018 were analyzed by using IGS products: DOYs 52–71 and DOYs 172–191. For the first period, two different types of ephemeris were used: those received in IGS YEL2 station and the BRDM ones. Milena (E14) and Doresa (E18) satellites show a higher SISE(orbit) than the others. If validity time is reduced, the SISE(orbit) RMS of Milena (E14) and Doresa (E18) greatly decreases differently from the other satellites, for which the improvement, although present, is small. Milena (E14) and Doresa (E18) reach a SISE(orbit) RMS of about 1 m (comparable to that of the other Galileo satellites reach with the nominal validity time) when validity time of 1800 s is used. Therefore, using this threshold, the two satellites could be used to improve single point positioning accuracy.
format Online
Article
Text
id pubmed-6515225
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-65152252019-05-30 Signal in Space Error and Ephemeris Validity Time Evaluation of Milena and Doresa Galileo Satellites † Robustelli, Umberto Benassai, Guido Pugliano, Giovanni Sensors (Basel) Article In August 2016, Milena (E14) and Doresa (E18) satellites started to broadcast ephemeris in navigation message for testing purposes. If these satellites could be used, an improvement in the position accuracy would be achieved. A small error in the ephemeris would impact the accuracy of positioning up to ±2.5 m, thus orbit error must be assessed. The ephemeris quality was evaluated by calculating the SISE(orbit) (in orbit Signal In Space Error) using six different ephemeris validity time thresholds (14,400 s, 10,800 s, 7200 s, 3600 s, 1800 s, and 900 s). Two different periods of 2018 were analyzed by using IGS products: DOYs 52–71 and DOYs 172–191. For the first period, two different types of ephemeris were used: those received in IGS YEL2 station and the BRDM ones. Milena (E14) and Doresa (E18) satellites show a higher SISE(orbit) than the others. If validity time is reduced, the SISE(orbit) RMS of Milena (E14) and Doresa (E18) greatly decreases differently from the other satellites, for which the improvement, although present, is small. Milena (E14) and Doresa (E18) reach a SISE(orbit) RMS of about 1 m (comparable to that of the other Galileo satellites reach with the nominal validity time) when validity time of 1800 s is used. Therefore, using this threshold, the two satellites could be used to improve single point positioning accuracy. MDPI 2019-04-14 /pmc/articles/PMC6515225/ /pubmed/31013977 http://dx.doi.org/10.3390/s19081786 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Robustelli, Umberto
Benassai, Guido
Pugliano, Giovanni
Signal in Space Error and Ephemeris Validity Time Evaluation of Milena and Doresa Galileo Satellites †
title Signal in Space Error and Ephemeris Validity Time Evaluation of Milena and Doresa Galileo Satellites †
title_full Signal in Space Error and Ephemeris Validity Time Evaluation of Milena and Doresa Galileo Satellites †
title_fullStr Signal in Space Error and Ephemeris Validity Time Evaluation of Milena and Doresa Galileo Satellites †
title_full_unstemmed Signal in Space Error and Ephemeris Validity Time Evaluation of Milena and Doresa Galileo Satellites †
title_short Signal in Space Error and Ephemeris Validity Time Evaluation of Milena and Doresa Galileo Satellites †
title_sort signal in space error and ephemeris validity time evaluation of milena and doresa galileo satellites †
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6515225/
https://www.ncbi.nlm.nih.gov/pubmed/31013977
http://dx.doi.org/10.3390/s19081786
work_keys_str_mv AT robustelliumberto signalinspaceerrorandephemerisvaliditytimeevaluationofmilenaanddoresagalileosatellites
AT benassaiguido signalinspaceerrorandephemerisvaliditytimeevaluationofmilenaanddoresagalileosatellites
AT puglianogiovanni signalinspaceerrorandephemerisvaliditytimeevaluationofmilenaanddoresagalileosatellites