Augmentation of Electrocardiographic QRS R-Amplitude Precedes Radiocontrast-Induced Hypotension during Mobile Computed Tomography Scanning
Although intravenous administration of contrast media may trigger a variety of adverse reactions, sedated patients undergoing computed tomography (CT) scanning usually are not able to report their symptoms, which may delay detection of adverse reactions. Furthermore, changes in vital signs cannot be...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6518100/ https://www.ncbi.nlm.nih.gov/pubmed/31013769 http://dx.doi.org/10.3390/jcm8040505 |
_version_ | 1783418393577127936 |
---|---|
author | Kwon, Hye-Mee Kim, Sung-Hoon Park, Hee-Sun Park, Yong-Seok Moon, Young-Jin Kim, Jae-Man Thiele, Robert |
author_facet | Kwon, Hye-Mee Kim, Sung-Hoon Park, Hee-Sun Park, Yong-Seok Moon, Young-Jin Kim, Jae-Man Thiele, Robert |
author_sort | Kwon, Hye-Mee |
collection | PubMed |
description | Although intravenous administration of contrast media may trigger a variety of adverse reactions, sedated patients undergoing computed tomography (CT) scanning usually are not able to report their symptoms, which may delay detection of adverse reactions. Furthermore, changes in vital signs cannot be typically measured during mobile CT scanning, which worsens the situation. We aimed to characterize contrast-related hemodynamic changes that occur during mobile CT scanning and predict sudden hypotension based on subtle but robust changes in the electrocardiogram (ECG). We analyzed the digitized hemodynamic data of 20 consecutive patients who underwent clipping of a cerebral artery aneurysm and contrast-enhanced CT scanning following the surgical procedure. Hemodynamic variables, including ECG findings, invasive blood pressure (BP), pulse oximetry results, capnography findings, cardiac output, and systemic vascular resistance, were monitored simultaneously. We measured morphological changes in ECG-derived parameters, including the R–R interval, ST height, and QRS R-amplitude, on a beat-to-beat basis, and evaluated the correlation between those parameters and hemodynamic changes. After the radiocontrast injection, systolic BP decreased by a median 53 mmHg from baseline and spontaneously recovered after 63 ± 19 s. An increase in QRS R-amplitude (median 0.43 mV) occurred 25 ± 10 s before hypotension developed. The receiver operating characteristic curve showed that a 16% increase in QRS R-amplitude can predict a decrease in systolic BP of >25% (area under the curve 0.852). Increased cardiac output (median delta 2.7 L/min from baseline) and decreased systemic vascular resistance (median delta 857 dyn·s/cm(5) from baseline) were also observed during hypotension. During mobile CT scanning, profound but transient hypotension can be observed, associated with decreased vascular resistance. Augmentation of QRS R-amplitude from an ECG represents a sensitive surrogate for onset of a hypotensive episode after contrast injection, thereby serving as a simple and continuous noninvasive hemodynamic monitoring tool. |
format | Online Article Text |
id | pubmed-6518100 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-65181002019-05-31 Augmentation of Electrocardiographic QRS R-Amplitude Precedes Radiocontrast-Induced Hypotension during Mobile Computed Tomography Scanning Kwon, Hye-Mee Kim, Sung-Hoon Park, Hee-Sun Park, Yong-Seok Moon, Young-Jin Kim, Jae-Man Thiele, Robert J Clin Med Article Although intravenous administration of contrast media may trigger a variety of adverse reactions, sedated patients undergoing computed tomography (CT) scanning usually are not able to report their symptoms, which may delay detection of adverse reactions. Furthermore, changes in vital signs cannot be typically measured during mobile CT scanning, which worsens the situation. We aimed to characterize contrast-related hemodynamic changes that occur during mobile CT scanning and predict sudden hypotension based on subtle but robust changes in the electrocardiogram (ECG). We analyzed the digitized hemodynamic data of 20 consecutive patients who underwent clipping of a cerebral artery aneurysm and contrast-enhanced CT scanning following the surgical procedure. Hemodynamic variables, including ECG findings, invasive blood pressure (BP), pulse oximetry results, capnography findings, cardiac output, and systemic vascular resistance, were monitored simultaneously. We measured morphological changes in ECG-derived parameters, including the R–R interval, ST height, and QRS R-amplitude, on a beat-to-beat basis, and evaluated the correlation between those parameters and hemodynamic changes. After the radiocontrast injection, systolic BP decreased by a median 53 mmHg from baseline and spontaneously recovered after 63 ± 19 s. An increase in QRS R-amplitude (median 0.43 mV) occurred 25 ± 10 s before hypotension developed. The receiver operating characteristic curve showed that a 16% increase in QRS R-amplitude can predict a decrease in systolic BP of >25% (area under the curve 0.852). Increased cardiac output (median delta 2.7 L/min from baseline) and decreased systemic vascular resistance (median delta 857 dyn·s/cm(5) from baseline) were also observed during hypotension. During mobile CT scanning, profound but transient hypotension can be observed, associated with decreased vascular resistance. Augmentation of QRS R-amplitude from an ECG represents a sensitive surrogate for onset of a hypotensive episode after contrast injection, thereby serving as a simple and continuous noninvasive hemodynamic monitoring tool. MDPI 2019-04-12 /pmc/articles/PMC6518100/ /pubmed/31013769 http://dx.doi.org/10.3390/jcm8040505 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kwon, Hye-Mee Kim, Sung-Hoon Park, Hee-Sun Park, Yong-Seok Moon, Young-Jin Kim, Jae-Man Thiele, Robert Augmentation of Electrocardiographic QRS R-Amplitude Precedes Radiocontrast-Induced Hypotension during Mobile Computed Tomography Scanning |
title | Augmentation of Electrocardiographic QRS R-Amplitude Precedes Radiocontrast-Induced Hypotension during Mobile Computed Tomography Scanning |
title_full | Augmentation of Electrocardiographic QRS R-Amplitude Precedes Radiocontrast-Induced Hypotension during Mobile Computed Tomography Scanning |
title_fullStr | Augmentation of Electrocardiographic QRS R-Amplitude Precedes Radiocontrast-Induced Hypotension during Mobile Computed Tomography Scanning |
title_full_unstemmed | Augmentation of Electrocardiographic QRS R-Amplitude Precedes Radiocontrast-Induced Hypotension during Mobile Computed Tomography Scanning |
title_short | Augmentation of Electrocardiographic QRS R-Amplitude Precedes Radiocontrast-Induced Hypotension during Mobile Computed Tomography Scanning |
title_sort | augmentation of electrocardiographic qrs r-amplitude precedes radiocontrast-induced hypotension during mobile computed tomography scanning |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6518100/ https://www.ncbi.nlm.nih.gov/pubmed/31013769 http://dx.doi.org/10.3390/jcm8040505 |
work_keys_str_mv | AT kwonhyemee augmentationofelectrocardiographicqrsramplitudeprecedesradiocontrastinducedhypotensionduringmobilecomputedtomographyscanning AT kimsunghoon augmentationofelectrocardiographicqrsramplitudeprecedesradiocontrastinducedhypotensionduringmobilecomputedtomographyscanning AT parkheesun augmentationofelectrocardiographicqrsramplitudeprecedesradiocontrastinducedhypotensionduringmobilecomputedtomographyscanning AT parkyongseok augmentationofelectrocardiographicqrsramplitudeprecedesradiocontrastinducedhypotensionduringmobilecomputedtomographyscanning AT moonyoungjin augmentationofelectrocardiographicqrsramplitudeprecedesradiocontrastinducedhypotensionduringmobilecomputedtomographyscanning AT kimjaeman augmentationofelectrocardiographicqrsramplitudeprecedesradiocontrastinducedhypotensionduringmobilecomputedtomographyscanning AT thielerobert augmentationofelectrocardiographicqrsramplitudeprecedesradiocontrastinducedhypotensionduringmobilecomputedtomographyscanning |