Cargando…
Endoscopic Ultrasonography-Guided Fine Needle Aspiration for Extrahepatic Cholangiocarcinoma: A Safe Tissue Sampling Modality
Few studies have compared the diagnostic utility of endoscopic ultrasonography-guided fine needle aspiration (EUS-FNA) and endoscopic retrograde cholangiopancreatography (ERCP) tissue sampling for extrahepatic cholangiocarcinoma (ECC). We evaluated the efficacy and safety of EUS-FNA for diagnosing E...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6518173/ https://www.ncbi.nlm.nih.gov/pubmed/30934706 http://dx.doi.org/10.3390/jcm8040417 |
_version_ | 1783418405548720128 |
---|---|
author | Onoyama, Takumi Matsumoto, Kazuya Takeda, Yohei Kawata, Soichiro Kurumi, Hiroki Koda, Hiroki Yamashita, Taro Takata, Tomoaki Isomoto, Hajime |
author_facet | Onoyama, Takumi Matsumoto, Kazuya Takeda, Yohei Kawata, Soichiro Kurumi, Hiroki Koda, Hiroki Yamashita, Taro Takata, Tomoaki Isomoto, Hajime |
author_sort | Onoyama, Takumi |
collection | PubMed |
description | Few studies have compared the diagnostic utility of endoscopic ultrasonography-guided fine needle aspiration (EUS-FNA) and endoscopic retrograde cholangiopancreatography (ERCP) tissue sampling for extrahepatic cholangiocarcinoma (ECC). We evaluated the efficacy and safety of EUS-FNA for diagnosing ECC compared with ERCP tissue sampling. Patients who underwent EUS-FNA or ERCP tissue sampling to differentiate ECC from benign biliary disease were enrolled retrospectively between October 2011 and March 2017. We evaluated diagnostic performances of EUS-FNA and ERCP tissue sampling based on pathological evaluation. We compared adverse events in EUS-FNA and ERCP tissue sampling. We enrolled 73 patients with biliary disease and performed EUS-FNA and ERCP in 19 and 54 patients, respectively. Sensitivity, specificity, and accuracy of ERCP tissue sampling were 76.0%, 100%, and 88.9%, respectively, and for EUS-FNA these were 81.8%, 87.5%, and 84.2%, respectively. Statistical values of ERCP tissue sampling and EUS-FNA were not significantly different. The adverse event frequency of EUS-FNA was significantly lower than that of ERCP tissue sampling (0% vs. 25.9%, p = 0.033). The diagnostic ability of EUS-FNA for ECC is similar to that of ERCP tissue sampling. EUS-FNA is a safer tissue sampling modality than ERCP for evaluating biliary disease. |
format | Online Article Text |
id | pubmed-6518173 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-65181732019-05-31 Endoscopic Ultrasonography-Guided Fine Needle Aspiration for Extrahepatic Cholangiocarcinoma: A Safe Tissue Sampling Modality Onoyama, Takumi Matsumoto, Kazuya Takeda, Yohei Kawata, Soichiro Kurumi, Hiroki Koda, Hiroki Yamashita, Taro Takata, Tomoaki Isomoto, Hajime J Clin Med Article Few studies have compared the diagnostic utility of endoscopic ultrasonography-guided fine needle aspiration (EUS-FNA) and endoscopic retrograde cholangiopancreatography (ERCP) tissue sampling for extrahepatic cholangiocarcinoma (ECC). We evaluated the efficacy and safety of EUS-FNA for diagnosing ECC compared with ERCP tissue sampling. Patients who underwent EUS-FNA or ERCP tissue sampling to differentiate ECC from benign biliary disease were enrolled retrospectively between October 2011 and March 2017. We evaluated diagnostic performances of EUS-FNA and ERCP tissue sampling based on pathological evaluation. We compared adverse events in EUS-FNA and ERCP tissue sampling. We enrolled 73 patients with biliary disease and performed EUS-FNA and ERCP in 19 and 54 patients, respectively. Sensitivity, specificity, and accuracy of ERCP tissue sampling were 76.0%, 100%, and 88.9%, respectively, and for EUS-FNA these were 81.8%, 87.5%, and 84.2%, respectively. Statistical values of ERCP tissue sampling and EUS-FNA were not significantly different. The adverse event frequency of EUS-FNA was significantly lower than that of ERCP tissue sampling (0% vs. 25.9%, p = 0.033). The diagnostic ability of EUS-FNA for ECC is similar to that of ERCP tissue sampling. EUS-FNA is a safer tissue sampling modality than ERCP for evaluating biliary disease. MDPI 2019-03-27 /pmc/articles/PMC6518173/ /pubmed/30934706 http://dx.doi.org/10.3390/jcm8040417 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Onoyama, Takumi Matsumoto, Kazuya Takeda, Yohei Kawata, Soichiro Kurumi, Hiroki Koda, Hiroki Yamashita, Taro Takata, Tomoaki Isomoto, Hajime Endoscopic Ultrasonography-Guided Fine Needle Aspiration for Extrahepatic Cholangiocarcinoma: A Safe Tissue Sampling Modality |
title | Endoscopic Ultrasonography-Guided Fine Needle Aspiration for Extrahepatic Cholangiocarcinoma: A Safe Tissue Sampling Modality |
title_full | Endoscopic Ultrasonography-Guided Fine Needle Aspiration for Extrahepatic Cholangiocarcinoma: A Safe Tissue Sampling Modality |
title_fullStr | Endoscopic Ultrasonography-Guided Fine Needle Aspiration for Extrahepatic Cholangiocarcinoma: A Safe Tissue Sampling Modality |
title_full_unstemmed | Endoscopic Ultrasonography-Guided Fine Needle Aspiration for Extrahepatic Cholangiocarcinoma: A Safe Tissue Sampling Modality |
title_short | Endoscopic Ultrasonography-Guided Fine Needle Aspiration for Extrahepatic Cholangiocarcinoma: A Safe Tissue Sampling Modality |
title_sort | endoscopic ultrasonography-guided fine needle aspiration for extrahepatic cholangiocarcinoma: a safe tissue sampling modality |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6518173/ https://www.ncbi.nlm.nih.gov/pubmed/30934706 http://dx.doi.org/10.3390/jcm8040417 |
work_keys_str_mv | AT onoyamatakumi endoscopicultrasonographyguidedfineneedleaspirationforextrahepaticcholangiocarcinomaasafetissuesamplingmodality AT matsumotokazuya endoscopicultrasonographyguidedfineneedleaspirationforextrahepaticcholangiocarcinomaasafetissuesamplingmodality AT takedayohei endoscopicultrasonographyguidedfineneedleaspirationforextrahepaticcholangiocarcinomaasafetissuesamplingmodality AT kawatasoichiro endoscopicultrasonographyguidedfineneedleaspirationforextrahepaticcholangiocarcinomaasafetissuesamplingmodality AT kurumihiroki endoscopicultrasonographyguidedfineneedleaspirationforextrahepaticcholangiocarcinomaasafetissuesamplingmodality AT kodahiroki endoscopicultrasonographyguidedfineneedleaspirationforextrahepaticcholangiocarcinomaasafetissuesamplingmodality AT yamashitataro endoscopicultrasonographyguidedfineneedleaspirationforextrahepaticcholangiocarcinomaasafetissuesamplingmodality AT takatatomoaki endoscopicultrasonographyguidedfineneedleaspirationforextrahepaticcholangiocarcinomaasafetissuesamplingmodality AT isomotohajime endoscopicultrasonographyguidedfineneedleaspirationforextrahepaticcholangiocarcinomaasafetissuesamplingmodality |