Selection Criteria for Determination of Optimal Reconstruction Method for Cu-64 Trastuzumab Dosimetry on Siemens Inveon PET Scanner

The goal of this study was to suggest criteria for the determination of the optimal image reconstruction algorithm for image-based dosimetry of Cu-64 trastuzumab PET in a mouse model. Image qualities, such as recovery coefficient (RC), spill-over ratio (SOR), and non-uniformity (NU), were measured a...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Seonhwa, Kim, Hyeongi, Kang, Ye-rin, Kim, Hyungwoo, Kim, Jung Young, Lee, Yong-Jin, Kim, Jung Min, Kim, Jin Su
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6518359/
https://www.ncbi.nlm.nih.gov/pubmed/31014003
http://dx.doi.org/10.3390/jcm8040512
_version_ 1783418438348177408
author Lee, Seonhwa
Kim, Hyeongi
Kang, Ye-rin
Kim, Hyungwoo
Kim, Jung Young
Lee, Yong-Jin
Kim, Jung Min
Kim, Jin Su
author_facet Lee, Seonhwa
Kim, Hyeongi
Kang, Ye-rin
Kim, Hyungwoo
Kim, Jung Young
Lee, Yong-Jin
Kim, Jung Min
Kim, Jin Su
author_sort Lee, Seonhwa
collection PubMed
description The goal of this study was to suggest criteria for the determination of the optimal image reconstruction algorithm for image-based dosimetry of Cu-64 trastuzumab PET in a mouse model. Image qualities, such as recovery coefficient (RC), spill-over ratio (SOR), and non-uniformity (NU), were measured according to National Electrical Manufacturers Association (NEMA) NU4-2008. Mice bearing a subcutaneous tumor ([Formula: see text] , HER2 NCI N87) were injected with monoclonal antibodies (trastuzumab) with Cu-64. Preclinical mouse PET images were acquired at 4 time points after injection (2, 15, 40 and 64 h). Phantom and Cu-64 trastuzumab PET images were reconstructed using various reconstruction algorithms (filtered back projection (FBP), 3D reprojection algorithm (FBP-3DRP), 2D ordered subset expectation maximization (OSEM 2D), and OSEM 3D maximum a posteriori (OSEM3D-MAP)) and filters. The absorbed dose for the tumor and the effective dose for organs for Cu-64 trastuzumab PET were calculated using the OLINDA/EXM program with various reconstruction algorithms. Absorbed dose for the tumor ranged from 923 mGy/MBq to 1830 mGy/MBq with application of reconstruction algorithms and filters. When OSEM2D was used, the effective osteogenic dose increased from 0.0031 to 0.0245 with an increase in the iteration number (1 to 10). In the region of kidney, the effective dose increased from 0.1870 to 1.4100 when OSEM2D was used with iteration number 1 to 10. To determine the optimal reconstruction algorithms and filters, a correlation between RC and NU was plotted and selection criteria (0.9 < RC < 1.0 and < 10% of NU) were suggested. According to the selection criteria, OSEM2D (iteration 1) was chosen for the optimal reconstruction algorithm. OSEM2D (iteration 10) provided 154.7% overestimated effective dose and FBP with a Butterworth filter provided 20.9% underestimated effective dose. We suggested OSEM2D (iteration 1) for the calculation of the effective dose of Cu-64 trastuzumab on an Inveon PET scanner.
format Online
Article
Text
id pubmed-6518359
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-65183592019-05-31 Selection Criteria for Determination of Optimal Reconstruction Method for Cu-64 Trastuzumab Dosimetry on Siemens Inveon PET Scanner Lee, Seonhwa Kim, Hyeongi Kang, Ye-rin Kim, Hyungwoo Kim, Jung Young Lee, Yong-Jin Kim, Jung Min Kim, Jin Su J Clin Med Article The goal of this study was to suggest criteria for the determination of the optimal image reconstruction algorithm for image-based dosimetry of Cu-64 trastuzumab PET in a mouse model. Image qualities, such as recovery coefficient (RC), spill-over ratio (SOR), and non-uniformity (NU), were measured according to National Electrical Manufacturers Association (NEMA) NU4-2008. Mice bearing a subcutaneous tumor ([Formula: see text] , HER2 NCI N87) were injected with monoclonal antibodies (trastuzumab) with Cu-64. Preclinical mouse PET images were acquired at 4 time points after injection (2, 15, 40 and 64 h). Phantom and Cu-64 trastuzumab PET images were reconstructed using various reconstruction algorithms (filtered back projection (FBP), 3D reprojection algorithm (FBP-3DRP), 2D ordered subset expectation maximization (OSEM 2D), and OSEM 3D maximum a posteriori (OSEM3D-MAP)) and filters. The absorbed dose for the tumor and the effective dose for organs for Cu-64 trastuzumab PET were calculated using the OLINDA/EXM program with various reconstruction algorithms. Absorbed dose for the tumor ranged from 923 mGy/MBq to 1830 mGy/MBq with application of reconstruction algorithms and filters. When OSEM2D was used, the effective osteogenic dose increased from 0.0031 to 0.0245 with an increase in the iteration number (1 to 10). In the region of kidney, the effective dose increased from 0.1870 to 1.4100 when OSEM2D was used with iteration number 1 to 10. To determine the optimal reconstruction algorithms and filters, a correlation between RC and NU was plotted and selection criteria (0.9 < RC < 1.0 and < 10% of NU) were suggested. According to the selection criteria, OSEM2D (iteration 1) was chosen for the optimal reconstruction algorithm. OSEM2D (iteration 10) provided 154.7% overestimated effective dose and FBP with a Butterworth filter provided 20.9% underestimated effective dose. We suggested OSEM2D (iteration 1) for the calculation of the effective dose of Cu-64 trastuzumab on an Inveon PET scanner. MDPI 2019-04-14 /pmc/articles/PMC6518359/ /pubmed/31014003 http://dx.doi.org/10.3390/jcm8040512 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lee, Seonhwa
Kim, Hyeongi
Kang, Ye-rin
Kim, Hyungwoo
Kim, Jung Young
Lee, Yong-Jin
Kim, Jung Min
Kim, Jin Su
Selection Criteria for Determination of Optimal Reconstruction Method for Cu-64 Trastuzumab Dosimetry on Siemens Inveon PET Scanner
title Selection Criteria for Determination of Optimal Reconstruction Method for Cu-64 Trastuzumab Dosimetry on Siemens Inveon PET Scanner
title_full Selection Criteria for Determination of Optimal Reconstruction Method for Cu-64 Trastuzumab Dosimetry on Siemens Inveon PET Scanner
title_fullStr Selection Criteria for Determination of Optimal Reconstruction Method for Cu-64 Trastuzumab Dosimetry on Siemens Inveon PET Scanner
title_full_unstemmed Selection Criteria for Determination of Optimal Reconstruction Method for Cu-64 Trastuzumab Dosimetry on Siemens Inveon PET Scanner
title_short Selection Criteria for Determination of Optimal Reconstruction Method for Cu-64 Trastuzumab Dosimetry on Siemens Inveon PET Scanner
title_sort selection criteria for determination of optimal reconstruction method for cu-64 trastuzumab dosimetry on siemens inveon pet scanner
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6518359/
https://www.ncbi.nlm.nih.gov/pubmed/31014003
http://dx.doi.org/10.3390/jcm8040512
work_keys_str_mv AT leeseonhwa selectioncriteriafordeterminationofoptimalreconstructionmethodforcu64trastuzumabdosimetryonsiemensinveonpetscanner
AT kimhyeongi selectioncriteriafordeterminationofoptimalreconstructionmethodforcu64trastuzumabdosimetryonsiemensinveonpetscanner
AT kangyerin selectioncriteriafordeterminationofoptimalreconstructionmethodforcu64trastuzumabdosimetryonsiemensinveonpetscanner
AT kimhyungwoo selectioncriteriafordeterminationofoptimalreconstructionmethodforcu64trastuzumabdosimetryonsiemensinveonpetscanner
AT kimjungyoung selectioncriteriafordeterminationofoptimalreconstructionmethodforcu64trastuzumabdosimetryonsiemensinveonpetscanner
AT leeyongjin selectioncriteriafordeterminationofoptimalreconstructionmethodforcu64trastuzumabdosimetryonsiemensinveonpetscanner
AT kimjungmin selectioncriteriafordeterminationofoptimalreconstructionmethodforcu64trastuzumabdosimetryonsiemensinveonpetscanner
AT kimjinsu selectioncriteriafordeterminationofoptimalreconstructionmethodforcu64trastuzumabdosimetryonsiemensinveonpetscanner