Cargando…

Comparison of data‐acquisition methods for the identification and quantification of histone post‐translational modifications on a Q Exactive HF hybrid quadrupole Orbitrap mass spectrometer

RATIONALE: Histone post‐translational modifications (PTMs) play key roles in regulating eukaryotic gene expression. Mass spectrometry (MS) has emerged as a powerful method to characterize and quantify histone PTMs as it allows unbiased identification and quantification of multiple histone PTMs inclu...

Descripción completa

Detalles Bibliográficos
Autores principales: Cole, Joby, Hanson, Eleanor J., James, David C., Dockrell, David H., Dickman, Mark J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6519233/
https://www.ncbi.nlm.nih.gov/pubmed/30701600
http://dx.doi.org/10.1002/rcm.8401
_version_ 1783418603794595840
author Cole, Joby
Hanson, Eleanor J.
James, David C.
Dockrell, David H.
Dickman, Mark J.
author_facet Cole, Joby
Hanson, Eleanor J.
James, David C.
Dockrell, David H.
Dickman, Mark J.
author_sort Cole, Joby
collection PubMed
description RATIONALE: Histone post‐translational modifications (PTMs) play key roles in regulating eukaryotic gene expression. Mass spectrometry (MS) has emerged as a powerful method to characterize and quantify histone PTMs as it allows unbiased identification and quantification of multiple histone PTMs including combinations of the modifications present. METHODS: In this study we compared a range of data‐acquisition methods for the identification and quantification of the histone PTMs using a Q Exactive HF Orbitrap. We compared three different data‐dependent analysis (DDA) methods with MS2 resolutions of 120K, 60K, 30K. We also compared a range of data‐independent analysis (DIA) methods using MS2 isolation windows of 20 m/z and DIAvw to identify and quantify histone PTMs in Chinese hamster ovary (CHO) cells. RESULTS: The increased number of MS2 scans afforded by the lower resolution methods resulted in a higher number of queries, peptide sequence matches (PSMs) and a higher number of peptide proteoforms identified with a Mascot Ion score greater than 46. No difference in the proportion of peptide proteoforms with Delta scores >17 was observed. Lower coefficients of variation (CVs) were obtained in the DIA MS1 60 K MS2 30 K 20 m/z isolation windows compared with the other data‐acquisition methods. CONCLUSIONS: We observed that DIA which offers advantages in flexibility and identification of isobaric peptide proteoforms performs as well as DDA in the analysis of histone PTMs. We were able to identify 71 modified histone peptides for histone H3 and H4 and quantified 64 across each of the different acquisition methods.
format Online
Article
Text
id pubmed-6519233
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-65192332019-05-21 Comparison of data‐acquisition methods for the identification and quantification of histone post‐translational modifications on a Q Exactive HF hybrid quadrupole Orbitrap mass spectrometer Cole, Joby Hanson, Eleanor J. James, David C. Dockrell, David H. Dickman, Mark J. Rapid Commun Mass Spectrom Research Articles RATIONALE: Histone post‐translational modifications (PTMs) play key roles in regulating eukaryotic gene expression. Mass spectrometry (MS) has emerged as a powerful method to characterize and quantify histone PTMs as it allows unbiased identification and quantification of multiple histone PTMs including combinations of the modifications present. METHODS: In this study we compared a range of data‐acquisition methods for the identification and quantification of the histone PTMs using a Q Exactive HF Orbitrap. We compared three different data‐dependent analysis (DDA) methods with MS2 resolutions of 120K, 60K, 30K. We also compared a range of data‐independent analysis (DIA) methods using MS2 isolation windows of 20 m/z and DIAvw to identify and quantify histone PTMs in Chinese hamster ovary (CHO) cells. RESULTS: The increased number of MS2 scans afforded by the lower resolution methods resulted in a higher number of queries, peptide sequence matches (PSMs) and a higher number of peptide proteoforms identified with a Mascot Ion score greater than 46. No difference in the proportion of peptide proteoforms with Delta scores >17 was observed. Lower coefficients of variation (CVs) were obtained in the DIA MS1 60 K MS2 30 K 20 m/z isolation windows compared with the other data‐acquisition methods. CONCLUSIONS: We observed that DIA which offers advantages in flexibility and identification of isobaric peptide proteoforms performs as well as DDA in the analysis of histone PTMs. We were able to identify 71 modified histone peptides for histone H3 and H4 and quantified 64 across each of the different acquisition methods. John Wiley and Sons Inc. 2019-04-26 2019-05-30 /pmc/articles/PMC6519233/ /pubmed/30701600 http://dx.doi.org/10.1002/rcm.8401 Text en © 2019 The Authors Rapid Communications in Mass Spectrometry Published by John Wiley & Sons Ltd This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Cole, Joby
Hanson, Eleanor J.
James, David C.
Dockrell, David H.
Dickman, Mark J.
Comparison of data‐acquisition methods for the identification and quantification of histone post‐translational modifications on a Q Exactive HF hybrid quadrupole Orbitrap mass spectrometer
title Comparison of data‐acquisition methods for the identification and quantification of histone post‐translational modifications on a Q Exactive HF hybrid quadrupole Orbitrap mass spectrometer
title_full Comparison of data‐acquisition methods for the identification and quantification of histone post‐translational modifications on a Q Exactive HF hybrid quadrupole Orbitrap mass spectrometer
title_fullStr Comparison of data‐acquisition methods for the identification and quantification of histone post‐translational modifications on a Q Exactive HF hybrid quadrupole Orbitrap mass spectrometer
title_full_unstemmed Comparison of data‐acquisition methods for the identification and quantification of histone post‐translational modifications on a Q Exactive HF hybrid quadrupole Orbitrap mass spectrometer
title_short Comparison of data‐acquisition methods for the identification and quantification of histone post‐translational modifications on a Q Exactive HF hybrid quadrupole Orbitrap mass spectrometer
title_sort comparison of data‐acquisition methods for the identification and quantification of histone post‐translational modifications on a q exactive hf hybrid quadrupole orbitrap mass spectrometer
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6519233/
https://www.ncbi.nlm.nih.gov/pubmed/30701600
http://dx.doi.org/10.1002/rcm.8401
work_keys_str_mv AT colejoby comparisonofdataacquisitionmethodsfortheidentificationandquantificationofhistoneposttranslationalmodificationsonaqexactivehfhybridquadrupoleorbitrapmassspectrometer
AT hansoneleanorj comparisonofdataacquisitionmethodsfortheidentificationandquantificationofhistoneposttranslationalmodificationsonaqexactivehfhybridquadrupoleorbitrapmassspectrometer
AT jamesdavidc comparisonofdataacquisitionmethodsfortheidentificationandquantificationofhistoneposttranslationalmodificationsonaqexactivehfhybridquadrupoleorbitrapmassspectrometer
AT dockrelldavidh comparisonofdataacquisitionmethodsfortheidentificationandquantificationofhistoneposttranslationalmodificationsonaqexactivehfhybridquadrupoleorbitrapmassspectrometer
AT dickmanmarkj comparisonofdataacquisitionmethodsfortheidentificationandquantificationofhistoneposttranslationalmodificationsonaqexactivehfhybridquadrupoleorbitrapmassspectrometer