Comparison of data‐acquisition methods for the identification and quantification of histone post‐translational modifications on a Q Exactive HF hybrid quadrupole Orbitrap mass spectrometer
RATIONALE: Histone post‐translational modifications (PTMs) play key roles in regulating eukaryotic gene expression. Mass spectrometry (MS) has emerged as a powerful method to characterize and quantify histone PTMs as it allows unbiased identification and quantification of multiple histone PTMs inclu...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6519233/ https://www.ncbi.nlm.nih.gov/pubmed/30701600 http://dx.doi.org/10.1002/rcm.8401 |
_version_ | 1783418603794595840 |
---|---|
author | Cole, Joby Hanson, Eleanor J. James, David C. Dockrell, David H. Dickman, Mark J. |
author_facet | Cole, Joby Hanson, Eleanor J. James, David C. Dockrell, David H. Dickman, Mark J. |
author_sort | Cole, Joby |
collection | PubMed |
description | RATIONALE: Histone post‐translational modifications (PTMs) play key roles in regulating eukaryotic gene expression. Mass spectrometry (MS) has emerged as a powerful method to characterize and quantify histone PTMs as it allows unbiased identification and quantification of multiple histone PTMs including combinations of the modifications present. METHODS: In this study we compared a range of data‐acquisition methods for the identification and quantification of the histone PTMs using a Q Exactive HF Orbitrap. We compared three different data‐dependent analysis (DDA) methods with MS2 resolutions of 120K, 60K, 30K. We also compared a range of data‐independent analysis (DIA) methods using MS2 isolation windows of 20 m/z and DIAvw to identify and quantify histone PTMs in Chinese hamster ovary (CHO) cells. RESULTS: The increased number of MS2 scans afforded by the lower resolution methods resulted in a higher number of queries, peptide sequence matches (PSMs) and a higher number of peptide proteoforms identified with a Mascot Ion score greater than 46. No difference in the proportion of peptide proteoforms with Delta scores >17 was observed. Lower coefficients of variation (CVs) were obtained in the DIA MS1 60 K MS2 30 K 20 m/z isolation windows compared with the other data‐acquisition methods. CONCLUSIONS: We observed that DIA which offers advantages in flexibility and identification of isobaric peptide proteoforms performs as well as DDA in the analysis of histone PTMs. We were able to identify 71 modified histone peptides for histone H3 and H4 and quantified 64 across each of the different acquisition methods. |
format | Online Article Text |
id | pubmed-6519233 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-65192332019-05-21 Comparison of data‐acquisition methods for the identification and quantification of histone post‐translational modifications on a Q Exactive HF hybrid quadrupole Orbitrap mass spectrometer Cole, Joby Hanson, Eleanor J. James, David C. Dockrell, David H. Dickman, Mark J. Rapid Commun Mass Spectrom Research Articles RATIONALE: Histone post‐translational modifications (PTMs) play key roles in regulating eukaryotic gene expression. Mass spectrometry (MS) has emerged as a powerful method to characterize and quantify histone PTMs as it allows unbiased identification and quantification of multiple histone PTMs including combinations of the modifications present. METHODS: In this study we compared a range of data‐acquisition methods for the identification and quantification of the histone PTMs using a Q Exactive HF Orbitrap. We compared three different data‐dependent analysis (DDA) methods with MS2 resolutions of 120K, 60K, 30K. We also compared a range of data‐independent analysis (DIA) methods using MS2 isolation windows of 20 m/z and DIAvw to identify and quantify histone PTMs in Chinese hamster ovary (CHO) cells. RESULTS: The increased number of MS2 scans afforded by the lower resolution methods resulted in a higher number of queries, peptide sequence matches (PSMs) and a higher number of peptide proteoforms identified with a Mascot Ion score greater than 46. No difference in the proportion of peptide proteoforms with Delta scores >17 was observed. Lower coefficients of variation (CVs) were obtained in the DIA MS1 60 K MS2 30 K 20 m/z isolation windows compared with the other data‐acquisition methods. CONCLUSIONS: We observed that DIA which offers advantages in flexibility and identification of isobaric peptide proteoforms performs as well as DDA in the analysis of histone PTMs. We were able to identify 71 modified histone peptides for histone H3 and H4 and quantified 64 across each of the different acquisition methods. John Wiley and Sons Inc. 2019-04-26 2019-05-30 /pmc/articles/PMC6519233/ /pubmed/30701600 http://dx.doi.org/10.1002/rcm.8401 Text en © 2019 The Authors Rapid Communications in Mass Spectrometry Published by John Wiley & Sons Ltd This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Articles Cole, Joby Hanson, Eleanor J. James, David C. Dockrell, David H. Dickman, Mark J. Comparison of data‐acquisition methods for the identification and quantification of histone post‐translational modifications on a Q Exactive HF hybrid quadrupole Orbitrap mass spectrometer |
title | Comparison of data‐acquisition methods for the identification and quantification of histone post‐translational modifications on a Q Exactive HF hybrid quadrupole Orbitrap mass spectrometer |
title_full | Comparison of data‐acquisition methods for the identification and quantification of histone post‐translational modifications on a Q Exactive HF hybrid quadrupole Orbitrap mass spectrometer |
title_fullStr | Comparison of data‐acquisition methods for the identification and quantification of histone post‐translational modifications on a Q Exactive HF hybrid quadrupole Orbitrap mass spectrometer |
title_full_unstemmed | Comparison of data‐acquisition methods for the identification and quantification of histone post‐translational modifications on a Q Exactive HF hybrid quadrupole Orbitrap mass spectrometer |
title_short | Comparison of data‐acquisition methods for the identification and quantification of histone post‐translational modifications on a Q Exactive HF hybrid quadrupole Orbitrap mass spectrometer |
title_sort | comparison of data‐acquisition methods for the identification and quantification of histone post‐translational modifications on a q exactive hf hybrid quadrupole orbitrap mass spectrometer |
topic | Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6519233/ https://www.ncbi.nlm.nih.gov/pubmed/30701600 http://dx.doi.org/10.1002/rcm.8401 |
work_keys_str_mv | AT colejoby comparisonofdataacquisitionmethodsfortheidentificationandquantificationofhistoneposttranslationalmodificationsonaqexactivehfhybridquadrupoleorbitrapmassspectrometer AT hansoneleanorj comparisonofdataacquisitionmethodsfortheidentificationandquantificationofhistoneposttranslationalmodificationsonaqexactivehfhybridquadrupoleorbitrapmassspectrometer AT jamesdavidc comparisonofdataacquisitionmethodsfortheidentificationandquantificationofhistoneposttranslationalmodificationsonaqexactivehfhybridquadrupoleorbitrapmassspectrometer AT dockrelldavidh comparisonofdataacquisitionmethodsfortheidentificationandquantificationofhistoneposttranslationalmodificationsonaqexactivehfhybridquadrupoleorbitrapmassspectrometer AT dickmanmarkj comparisonofdataacquisitionmethodsfortheidentificationandquantificationofhistoneposttranslationalmodificationsonaqexactivehfhybridquadrupoleorbitrapmassspectrometer |