This work discusses the parameters and characteristics required on the development of a scalable and reliable electrochemical sensor board for detecting 8-hydroxy-2′-deoxyguanosine (8-OHdG), an oxidative stress biomarker for diabetic nephropathy, cancer and Parkinson’s disease. We used Printed Circu...

Descripción completa

Detalles Bibliográficos
Autores principales: Faria, Aline M., Peixoto, Elisa B. M. I., Adamo, Cristiane B., Flacker, Alexandre, Longo, Elson, Mazon, Talita
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6520373/
https://www.ncbi.nlm.nih.gov/pubmed/31092871
http://dx.doi.org/10.1038/s41598-019-43680-y
_version_ 1783418728683143168
author Faria, Aline M.
Peixoto, Elisa B. M. I.
Adamo, Cristiane B.
Flacker, Alexandre
Longo, Elson
Mazon, Talita
author_facet Faria, Aline M.
Peixoto, Elisa B. M. I.
Adamo, Cristiane B.
Flacker, Alexandre
Longo, Elson
Mazon, Talita
author_sort Faria, Aline M.
collection PubMed
description This work discusses the parameters and characteristics required on the development of a scalable and reliable electrochemical sensor board for detecting 8-hydroxy-2′-deoxyguanosine (8-OHdG), an oxidative stress biomarker for diabetic nephropathy, cancer and Parkinson’s disease. We used Printed Circuit Board (PCB) technology to make a precise, low-cost bare sensor board. ZnO nanorods (NRs) and ZnO NRs: reduced graphene oxide (RGO) composites were used as a pathway for antibody immobilization on the working electrode (WE). The parameters and characteristics of the WE were controlled for enhancing the quality of the electrochemical sensor board. Thickness of the gold and the presence of ZnO NRs or their composite on the WE have influence on charge transference process and reproducibility of the sensor board. The amount of the antibody, and its incubation period are crucial to avoid saturation of the sites during immobilization step and reduce the cost of the sensor. Our ZnO NRs-based electrochemical sensor board showed high sensitivity and selectivity to 8-OHdG with detection capacity in the range of 0.001–5.00 ng.mL(−1). The successful application of our immunosensor to detect 8-OHdG in urine was evidenced.
format Online
Article
Text
id pubmed-6520373
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-65203732019-05-28 Controlling parameters and characteristics of electrochemical biosensors for enhanced detection of 8-hydroxy-2′-deoxyguanosine Faria, Aline M. Peixoto, Elisa B. M. I. Adamo, Cristiane B. Flacker, Alexandre Longo, Elson Mazon, Talita Sci Rep Article This work discusses the parameters and characteristics required on the development of a scalable and reliable electrochemical sensor board for detecting 8-hydroxy-2′-deoxyguanosine (8-OHdG), an oxidative stress biomarker for diabetic nephropathy, cancer and Parkinson’s disease. We used Printed Circuit Board (PCB) technology to make a precise, low-cost bare sensor board. ZnO nanorods (NRs) and ZnO NRs: reduced graphene oxide (RGO) composites were used as a pathway for antibody immobilization on the working electrode (WE). The parameters and characteristics of the WE were controlled for enhancing the quality of the electrochemical sensor board. Thickness of the gold and the presence of ZnO NRs or their composite on the WE have influence on charge transference process and reproducibility of the sensor board. The amount of the antibody, and its incubation period are crucial to avoid saturation of the sites during immobilization step and reduce the cost of the sensor. Our ZnO NRs-based electrochemical sensor board showed high sensitivity and selectivity to 8-OHdG with detection capacity in the range of 0.001–5.00 ng.mL(−1). The successful application of our immunosensor to detect 8-OHdG in urine was evidenced. Nature Publishing Group UK 2019-05-15 /pmc/articles/PMC6520373/ /pubmed/31092871 http://dx.doi.org/10.1038/s41598-019-43680-y Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Faria, Aline M.
Peixoto, Elisa B. M. I.
Adamo, Cristiane B.
Flacker, Alexandre
Longo, Elson
Mazon, Talita
Controlling parameters and characteristics of electrochemical biosensors for enhanced detection of 8-hydroxy-2′-deoxyguanosine
title Controlling parameters and characteristics of electrochemical biosensors for enhanced detection of 8-hydroxy-2′-deoxyguanosine
title_full Controlling parameters and characteristics of electrochemical biosensors for enhanced detection of 8-hydroxy-2′-deoxyguanosine
title_fullStr Controlling parameters and characteristics of electrochemical biosensors for enhanced detection of 8-hydroxy-2′-deoxyguanosine
title_full_unstemmed Controlling parameters and characteristics of electrochemical biosensors for enhanced detection of 8-hydroxy-2′-deoxyguanosine
title_short Controlling parameters and characteristics of electrochemical biosensors for enhanced detection of 8-hydroxy-2′-deoxyguanosine
title_sort controlling parameters and characteristics of electrochemical biosensors for enhanced detection of 8-hydroxy-2′-deoxyguanosine
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6520373/
https://www.ncbi.nlm.nih.gov/pubmed/31092871
http://dx.doi.org/10.1038/s41598-019-43680-y
work_keys_str_mv AT fariaalinem controllingparametersandcharacteristicsofelectrochemicalbiosensorsforenhanceddetectionof8hydroxy2deoxyguanosine
AT peixotoelisabmi controllingparametersandcharacteristicsofelectrochemicalbiosensorsforenhanceddetectionof8hydroxy2deoxyguanosine
AT adamocristianeb controllingparametersandcharacteristicsofelectrochemicalbiosensorsforenhanceddetectionof8hydroxy2deoxyguanosine
AT flackeralexandre controllingparametersandcharacteristicsofelectrochemicalbiosensorsforenhanceddetectionof8hydroxy2deoxyguanosine
AT longoelson controllingparametersandcharacteristicsofelectrochemicalbiosensorsforenhanceddetectionof8hydroxy2deoxyguanosine
AT mazontalita controllingparametersandcharacteristicsofelectrochemicalbiosensorsforenhanceddetectionof8hydroxy2deoxyguanosine