Cargando…

Experiences of localization and removal of non-palpable subdermal contraceptive implants with ultrasound

OBJECTIVE: The aim of this study was to present experiences in localization and removal of non-palpable subdermal contraceptive implants with ultrasonography. METHODS: Medical records from January 1, 2016, to April 30, 2018, were retrospectively reviewed for 21 patients who were referred to a single...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, SooHyun, Choi, Young Sik, Kim, Jeong Sook, Kim, Sungjun, Cho, SiHyun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Obstetrics and Gynecology; Korean Society of Contraception and Reproductive Health; Korean Society of Gynecologic Endocrinology; Korean Society of Gynecologic Endoscopy and Minimal Invasive Surgery; Korean Society of Maternal Fetal Medicine; Korean Society of Ultrasound in Obstetrics and Gynecology; Korean Urogynecologic Society 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6520546/
https://www.ncbi.nlm.nih.gov/pubmed/31139592
http://dx.doi.org/10.5468/ogs.2019.62.3.166
_version_ 1783418758744768512
author Kim, SooHyun
Choi, Young Sik
Kim, Jeong Sook
Kim, Sungjun
Cho, SiHyun
author_facet Kim, SooHyun
Choi, Young Sik
Kim, Jeong Sook
Kim, Sungjun
Cho, SiHyun
author_sort Kim, SooHyun
collection PubMed
description OBJECTIVE: The aim of this study was to present experiences in localization and removal of non-palpable subdermal contraceptive implants with ultrasonography. METHODS: Medical records from January 1, 2016, to April 30, 2018, were retrospectively reviewed for 21 patients who were referred to a single institution and had an impalpable implant despite following the removal instruction. In all the cases, more than one attempt was made to remove the implant before referral. The rod was detected using radiography and ultrasonography. In all the cases, localization of the single implant was achieved with ultrasonography. The distal depth of the rod was measured, and skin marking was made following the echogenicity. The implants were subsequently removed under anesthesia. RESULTS: In 18 cases, the rods were localized using ultrasonography and successfully removed under local anesthesia. In the other three cases, removal with local anesthesia failed. Although the rod was detected successful with ultrasonography, the implants were removed under general anesthesia in the operating room. The depth from skin to rod, measured with ultrasonography, was >12.0 mm in all the cases and located deep in the muscular layer in the failure cases. The depth of the implants positively correlated with the time spent for removal (r=0.525; P=0.015). CONCLUSION: High frequency ultrasonography is a highly accurate tool for localization and measurement of the skin-to-rod depth. It is also useful for removing non-palpable implants. If the depth of the implant is >12.0 mm, removal of the implant in the operating room under general anesthesia is recommended.
format Online
Article
Text
id pubmed-6520546
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Korean Society of Obstetrics and Gynecology; Korean Society of Contraception and Reproductive Health; Korean Society of Gynecologic Endocrinology; Korean Society of Gynecologic Endoscopy and Minimal Invasive Surgery; Korean Society of Maternal Fetal Medicine; Korean Society of Ultrasound in Obstetrics and Gynecology; Korean Urogynecologic Society
record_format MEDLINE/PubMed
spelling pubmed-65205462019-05-28 Experiences of localization and removal of non-palpable subdermal contraceptive implants with ultrasound Kim, SooHyun Choi, Young Sik Kim, Jeong Sook Kim, Sungjun Cho, SiHyun Obstet Gynecol Sci Original Article OBJECTIVE: The aim of this study was to present experiences in localization and removal of non-palpable subdermal contraceptive implants with ultrasonography. METHODS: Medical records from January 1, 2016, to April 30, 2018, were retrospectively reviewed for 21 patients who were referred to a single institution and had an impalpable implant despite following the removal instruction. In all the cases, more than one attempt was made to remove the implant before referral. The rod was detected using radiography and ultrasonography. In all the cases, localization of the single implant was achieved with ultrasonography. The distal depth of the rod was measured, and skin marking was made following the echogenicity. The implants were subsequently removed under anesthesia. RESULTS: In 18 cases, the rods were localized using ultrasonography and successfully removed under local anesthesia. In the other three cases, removal with local anesthesia failed. Although the rod was detected successful with ultrasonography, the implants were removed under general anesthesia in the operating room. The depth from skin to rod, measured with ultrasonography, was >12.0 mm in all the cases and located deep in the muscular layer in the failure cases. The depth of the implants positively correlated with the time spent for removal (r=0.525; P=0.015). CONCLUSION: High frequency ultrasonography is a highly accurate tool for localization and measurement of the skin-to-rod depth. It is also useful for removing non-palpable implants. If the depth of the implant is >12.0 mm, removal of the implant in the operating room under general anesthesia is recommended. Korean Society of Obstetrics and Gynecology; Korean Society of Contraception and Reproductive Health; Korean Society of Gynecologic Endocrinology; Korean Society of Gynecologic Endoscopy and Minimal Invasive Surgery; Korean Society of Maternal Fetal Medicine; Korean Society of Ultrasound in Obstetrics and Gynecology; Korean Urogynecologic Society 2019-05 2019-04-17 /pmc/articles/PMC6520546/ /pubmed/31139592 http://dx.doi.org/10.5468/ogs.2019.62.3.166 Text en Copyright © 2019 Korean Society of Obstetrics and Gynecology http://creativecommons.org/licenses/by-nc/3.0/ Articles published in Obstet Gynecol Sci are open-access, distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kim, SooHyun
Choi, Young Sik
Kim, Jeong Sook
Kim, Sungjun
Cho, SiHyun
Experiences of localization and removal of non-palpable subdermal contraceptive implants with ultrasound
title Experiences of localization and removal of non-palpable subdermal contraceptive implants with ultrasound
title_full Experiences of localization and removal of non-palpable subdermal contraceptive implants with ultrasound
title_fullStr Experiences of localization and removal of non-palpable subdermal contraceptive implants with ultrasound
title_full_unstemmed Experiences of localization and removal of non-palpable subdermal contraceptive implants with ultrasound
title_short Experiences of localization and removal of non-palpable subdermal contraceptive implants with ultrasound
title_sort experiences of localization and removal of non-palpable subdermal contraceptive implants with ultrasound
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6520546/
https://www.ncbi.nlm.nih.gov/pubmed/31139592
http://dx.doi.org/10.5468/ogs.2019.62.3.166
work_keys_str_mv AT kimsoohyun experiencesoflocalizationandremovalofnonpalpablesubdermalcontraceptiveimplantswithultrasound
AT choiyoungsik experiencesoflocalizationandremovalofnonpalpablesubdermalcontraceptiveimplantswithultrasound
AT kimjeongsook experiencesoflocalizationandremovalofnonpalpablesubdermalcontraceptiveimplantswithultrasound
AT kimsungjun experiencesoflocalizationandremovalofnonpalpablesubdermalcontraceptiveimplantswithultrasound
AT chosihyun experiencesoflocalizationandremovalofnonpalpablesubdermalcontraceptiveimplantswithultrasound