Cargando…
Comparative study of OMNIgene®•SPUTUM reagent versus cold-chain for the transportation of sputum samples to GeneXpert®MTB/RIF testing sites in Malawi
BACKGROUND: The study was conducted in a remote sputum sample collection sites and GeneXpert® MTB/RIF testing centers to detect Mycobacterium tuberculosis in Malawi. The main purpose of the study was to evaluate whether sputum samples stored and transported with OMNIgene®•SPUTUM (OM-S) medium perfor...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6521431/ https://www.ncbi.nlm.nih.gov/pubmed/31096945 http://dx.doi.org/10.1186/s12879-019-4070-8 |
_version_ | 1783418956628885504 |
---|---|
author | Alemayehu, Wondwossen A. Neri, S. Dalebout, S. Nalikungwi, R. Trusov, A. Ahmed, E. Dimba, A. Weirich, A. Curry, P. S. Kelly-Cirino, C. D. |
author_facet | Alemayehu, Wondwossen A. Neri, S. Dalebout, S. Nalikungwi, R. Trusov, A. Ahmed, E. Dimba, A. Weirich, A. Curry, P. S. Kelly-Cirino, C. D. |
author_sort | Alemayehu, Wondwossen A. |
collection | PubMed |
description | BACKGROUND: The study was conducted in a remote sputum sample collection sites and GeneXpert® MTB/RIF testing centers to detect Mycobacterium tuberculosis in Malawi. The main purpose of the study was to evaluate whether sputum samples stored and transported with OMNIgene®•SPUTUM (OM-S) medium perform comparably to the routine cold-chain stored and transported samples for GeneXpert testing to detect Mycobacterium tuberculosis. METHODS: Two sputum samples from each of 362 tuberculosis suspects were randomly assigned to the OMNIgene treated (OM-S group) or the standard-of-care group (SOC; transported via cold chain). All specimens were tested at regional GeneXpert testing sites using the expectorated (raw) sputum protocol. Demographic, clinical, transport/storage and Xpert data were recorded for each specimen pair. Agreement between the SOC and OM-S groups’ Xpert results was evaluated using Cohen’s kappa analysis. RESULTS: Mean patient age was 42.3 years (range 2–79 years), 77% of patients were female, and 80% were HIV-positive. Mean transport/storage time was 6.7 days (range, 0–29 days). The rates of MTB positivity for the OM-S and SOC groups were comparable (11.8 and 11.2%, respectively), inter-test agreement was “very good” (κ = 0.97), and overall percent agreement was 99%. Two specimen pairs (both mucoid, one 13 days transport, one 1 day transport) had discordant Xpert results. CONCLUSION: OM-S-treated sputum specimens can undergo multi-day ambient-temperature storage as well as transport and yield Xpert results comparable to those of cold-chain-transported samples in Malawi. |
format | Online Article Text |
id | pubmed-6521431 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-65214312019-05-23 Comparative study of OMNIgene®•SPUTUM reagent versus cold-chain for the transportation of sputum samples to GeneXpert®MTB/RIF testing sites in Malawi Alemayehu, Wondwossen A. Neri, S. Dalebout, S. Nalikungwi, R. Trusov, A. Ahmed, E. Dimba, A. Weirich, A. Curry, P. S. Kelly-Cirino, C. D. BMC Infect Dis Research Article BACKGROUND: The study was conducted in a remote sputum sample collection sites and GeneXpert® MTB/RIF testing centers to detect Mycobacterium tuberculosis in Malawi. The main purpose of the study was to evaluate whether sputum samples stored and transported with OMNIgene®•SPUTUM (OM-S) medium perform comparably to the routine cold-chain stored and transported samples for GeneXpert testing to detect Mycobacterium tuberculosis. METHODS: Two sputum samples from each of 362 tuberculosis suspects were randomly assigned to the OMNIgene treated (OM-S group) or the standard-of-care group (SOC; transported via cold chain). All specimens were tested at regional GeneXpert testing sites using the expectorated (raw) sputum protocol. Demographic, clinical, transport/storage and Xpert data were recorded for each specimen pair. Agreement between the SOC and OM-S groups’ Xpert results was evaluated using Cohen’s kappa analysis. RESULTS: Mean patient age was 42.3 years (range 2–79 years), 77% of patients were female, and 80% were HIV-positive. Mean transport/storage time was 6.7 days (range, 0–29 days). The rates of MTB positivity for the OM-S and SOC groups were comparable (11.8 and 11.2%, respectively), inter-test agreement was “very good” (κ = 0.97), and overall percent agreement was 99%. Two specimen pairs (both mucoid, one 13 days transport, one 1 day transport) had discordant Xpert results. CONCLUSION: OM-S-treated sputum specimens can undergo multi-day ambient-temperature storage as well as transport and yield Xpert results comparable to those of cold-chain-transported samples in Malawi. BioMed Central 2019-05-16 /pmc/articles/PMC6521431/ /pubmed/31096945 http://dx.doi.org/10.1186/s12879-019-4070-8 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Alemayehu, Wondwossen A. Neri, S. Dalebout, S. Nalikungwi, R. Trusov, A. Ahmed, E. Dimba, A. Weirich, A. Curry, P. S. Kelly-Cirino, C. D. Comparative study of OMNIgene®•SPUTUM reagent versus cold-chain for the transportation of sputum samples to GeneXpert®MTB/RIF testing sites in Malawi |
title | Comparative study of OMNIgene®•SPUTUM reagent versus cold-chain for the transportation of sputum samples to GeneXpert®MTB/RIF testing sites in Malawi |
title_full | Comparative study of OMNIgene®•SPUTUM reagent versus cold-chain for the transportation of sputum samples to GeneXpert®MTB/RIF testing sites in Malawi |
title_fullStr | Comparative study of OMNIgene®•SPUTUM reagent versus cold-chain for the transportation of sputum samples to GeneXpert®MTB/RIF testing sites in Malawi |
title_full_unstemmed | Comparative study of OMNIgene®•SPUTUM reagent versus cold-chain for the transportation of sputum samples to GeneXpert®MTB/RIF testing sites in Malawi |
title_short | Comparative study of OMNIgene®•SPUTUM reagent versus cold-chain for the transportation of sputum samples to GeneXpert®MTB/RIF testing sites in Malawi |
title_sort | comparative study of omnigene®•sputum reagent versus cold-chain for the transportation of sputum samples to genexpert®mtb/rif testing sites in malawi |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6521431/ https://www.ncbi.nlm.nih.gov/pubmed/31096945 http://dx.doi.org/10.1186/s12879-019-4070-8 |
work_keys_str_mv | AT alemayehuwondwossena comparativestudyofomnigenesputumreagentversuscoldchainforthetransportationofsputumsamplestogenexpertmtbriftestingsitesinmalawi AT neris comparativestudyofomnigenesputumreagentversuscoldchainforthetransportationofsputumsamplestogenexpertmtbriftestingsitesinmalawi AT dalebouts comparativestudyofomnigenesputumreagentversuscoldchainforthetransportationofsputumsamplestogenexpertmtbriftestingsitesinmalawi AT nalikungwir comparativestudyofomnigenesputumreagentversuscoldchainforthetransportationofsputumsamplestogenexpertmtbriftestingsitesinmalawi AT trusova comparativestudyofomnigenesputumreagentversuscoldchainforthetransportationofsputumsamplestogenexpertmtbriftestingsitesinmalawi AT ahmede comparativestudyofomnigenesputumreagentversuscoldchainforthetransportationofsputumsamplestogenexpertmtbriftestingsitesinmalawi AT dimbaa comparativestudyofomnigenesputumreagentversuscoldchainforthetransportationofsputumsamplestogenexpertmtbriftestingsitesinmalawi AT weiricha comparativestudyofomnigenesputumreagentversuscoldchainforthetransportationofsputumsamplestogenexpertmtbriftestingsitesinmalawi AT curryps comparativestudyofomnigenesputumreagentversuscoldchainforthetransportationofsputumsamplestogenexpertmtbriftestingsitesinmalawi AT kellycirinocd comparativestudyofomnigenesputumreagentversuscoldchainforthetransportationofsputumsamplestogenexpertmtbriftestingsitesinmalawi |