3D printed testing aids for radiographic quality control
Quality control testing of radiographic and fluoroscopic imaging systems requires positioning of test objects in the x‐ray beam in a precise and repeatable fashion. In this work we present several three‐dimensional (3D) printed testing aids that improve efficiency, accuracy, and repeatability of qua...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6523005/ https://www.ncbi.nlm.nih.gov/pubmed/30955233 http://dx.doi.org/10.1002/acm2.12574 |
_version_ | 1783419233958363136 |
---|---|
author | Ogden, Kent M. Morabito, Kristin E. Depew, Paul K. |
author_facet | Ogden, Kent M. Morabito, Kristin E. Depew, Paul K. |
author_sort | Ogden, Kent M. |
collection | PubMed |
description | Quality control testing of radiographic and fluoroscopic imaging systems requires positioning of test objects in the x‐ray beam in a precise and repeatable fashion. In this work we present several three‐dimensional (3D) printed testing aids that improve efficiency, accuracy, and repeatability of quality control testing. We also present a new device for determining the location of the perpendicular ray in radiographic systems. These devices were designed in an open source software program (OpenScad, http://www.openscad.org) and 3D models were saved in .stl format for printing. The models were printed on either a MakerBot Replicator 2 or Replicator Z18 printer (MakerBot Industries, LLC, Brooklyn, NY). The testing aids were printed using polylactic acid (PLA) filament. To investigate the radiographic characteristics of the PLA used, test articles were printed and used to measure the half‐value layer (HVL) thicknesses in mm of PLA and half‐value densities (HVD) in g/cm(2) of PLA for two different colors and over a wide range of radiographic beam qualities, using a portable fluoroscopic c‐arm system. HVL thicknesses of clear PLA ranged from approximately 20 mm at 50 kV nominal tube voltage to 27 mm at 120 kV nominal tube voltage. For green PLA, the HVL thickness was 19 mm at 50 kV tube voltage and 25.7 mm at 120 kV tube voltage. The HVD of clear PLA ranged from 2.37 g/cm(2) at 50 kV nominal tube voltage to 3.19 g/cm(2) at 120 kV nominal tube voltage. For green PLA, the HVD was 2.35 g/cm(2) at 50 kV tube voltage and 3.17 g/cm(2) at 120 kV tube voltage. The cost of the devices range from under $2 to approximately $20 in materials. The files used to create the models are freely available at https://github.com/Upstate3DLab/3D-Printed-Radiographic-Test-Tools. |
format | Online Article Text |
id | pubmed-6523005 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-65230052019-05-24 3D printed testing aids for radiographic quality control Ogden, Kent M. Morabito, Kristin E. Depew, Paul K. J Appl Clin Med Phys Medical Imaging Quality control testing of radiographic and fluoroscopic imaging systems requires positioning of test objects in the x‐ray beam in a precise and repeatable fashion. In this work we present several three‐dimensional (3D) printed testing aids that improve efficiency, accuracy, and repeatability of quality control testing. We also present a new device for determining the location of the perpendicular ray in radiographic systems. These devices were designed in an open source software program (OpenScad, http://www.openscad.org) and 3D models were saved in .stl format for printing. The models were printed on either a MakerBot Replicator 2 or Replicator Z18 printer (MakerBot Industries, LLC, Brooklyn, NY). The testing aids were printed using polylactic acid (PLA) filament. To investigate the radiographic characteristics of the PLA used, test articles were printed and used to measure the half‐value layer (HVL) thicknesses in mm of PLA and half‐value densities (HVD) in g/cm(2) of PLA for two different colors and over a wide range of radiographic beam qualities, using a portable fluoroscopic c‐arm system. HVL thicknesses of clear PLA ranged from approximately 20 mm at 50 kV nominal tube voltage to 27 mm at 120 kV nominal tube voltage. For green PLA, the HVL thickness was 19 mm at 50 kV tube voltage and 25.7 mm at 120 kV tube voltage. The HVD of clear PLA ranged from 2.37 g/cm(2) at 50 kV nominal tube voltage to 3.19 g/cm(2) at 120 kV nominal tube voltage. For green PLA, the HVD was 2.35 g/cm(2) at 50 kV tube voltage and 3.17 g/cm(2) at 120 kV tube voltage. The cost of the devices range from under $2 to approximately $20 in materials. The files used to create the models are freely available at https://github.com/Upstate3DLab/3D-Printed-Radiographic-Test-Tools. John Wiley and Sons Inc. 2019-04-06 /pmc/articles/PMC6523005/ /pubmed/30955233 http://dx.doi.org/10.1002/acm2.12574 Text en © 2019 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Medical Imaging Ogden, Kent M. Morabito, Kristin E. Depew, Paul K. 3D printed testing aids for radiographic quality control |
title | 3D printed testing aids for radiographic quality control |
title_full | 3D printed testing aids for radiographic quality control |
title_fullStr | 3D printed testing aids for radiographic quality control |
title_full_unstemmed | 3D printed testing aids for radiographic quality control |
title_short | 3D printed testing aids for radiographic quality control |
title_sort | 3d printed testing aids for radiographic quality control |
topic | Medical Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6523005/ https://www.ncbi.nlm.nih.gov/pubmed/30955233 http://dx.doi.org/10.1002/acm2.12574 |
work_keys_str_mv | AT ogdenkentm 3dprintedtestingaidsforradiographicqualitycontrol AT morabitokristine 3dprintedtestingaidsforradiographicqualitycontrol AT depewpaulk 3dprintedtestingaidsforradiographicqualitycontrol |