Quantitative assessment of disease markers using the naked eye: point-of-care testing with gas generation-based biosensor immunochromatographic strips

BACKGROUND: Immunochromatographic strips (ICSs) are a practical tool commonly used in point-of-care testing (POCT) applications. However, ICSs that are currently available have low sensitivity and require expensive equipment for quantitative analysis. These limitations prohibit their extensive use i...

Descripción completa

Detalles Bibliográficos
Autores principales: Fu, Qiangqiang, Wu, Ze, Li, Jingxia, Wu, Zengfeng, Zhong, Hui, Yang, Quanli, Liu, Qihui, Liu, Zonghua, Sheng, Lianghe, Xu, Meng, Li, Tingting, Yin, Zhinan, Wu, Yangzhe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6524263/
https://www.ncbi.nlm.nih.gov/pubmed/31101112
http://dx.doi.org/10.1186/s12951-019-0493-z
Descripción
Sumario:BACKGROUND: Immunochromatographic strips (ICSs) are a practical tool commonly used in point-of-care testing (POCT) applications. However, ICSs that are currently available have low sensitivity and require expensive equipment for quantitative analysis. These limitations prohibit their extensive use in areas where medical resources are scarce. METHODS: We developed a novel POCT platform by integrating a gas generation biosensor with Au@Pt Core/Shell nanoparticle (Au@PtNPs)-based ICSs (G-ICSs). The resulting G-ICSs enabled the convenient and quantitative assessment of a target protein using the naked eye, without the need for auxiliary equipment or complicated computation. To assess this platform, C-reactive protein (CRP), a biomarker commonly used for the diagnosis of acute, infectious diseases was chosen as a proof-of-concept test. RESULTS: The linear detection range (LDR) of the G-ICSs for CRP was 0.05–6.25 μg/L with a limit of detection (LOD) of 0.041 μg/L. The G-ICSs had higher sensitivity and wider LDR when compared with commonly used AuNPs and fluorescent-based ICSs. When compared with results from a chemiluminescent immunoassay, G-ICS concordance rates for CRP detection in serum samples ranged from 93.72 to 110.99%. CONCLUSIONS: These results demonstrated that G-ICSs have wide applicability in family diagnosis and community medical institutions, especially in areas with poor medical resources. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12951-019-0493-z) contains supplementary material, which is available to authorized users.