Cargando…

Patient-specific drill template for C2 transoral pedicle insertion in complete reduction of atlantoaxial dislocation: cadaveric efficacy and accuracy assessments

BACKGROUND: The transoral atlantoaxial reduction plate (TARP) is an effective advance in the treatment of atlantoaxial dislocation (AAD) and can enable the performance of anterior atlantoaxial release, reduction, decompression, and internal fixation in a one-stage operation. However, accurate transo...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Lijun, Zhu, Meisong, Peng, Peng, Zhang, Xintao, Zhou, Xiaoqi, Li, Jianyi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6524296/
https://www.ncbi.nlm.nih.gov/pubmed/31096990
http://dx.doi.org/10.1186/s13018-019-1189-7
_version_ 1783419529731244032
author Lin, Lijun
Zhu, Meisong
Peng, Peng
Zhang, Xintao
Zhou, Xiaoqi
Li, Jianyi
author_facet Lin, Lijun
Zhu, Meisong
Peng, Peng
Zhang, Xintao
Zhou, Xiaoqi
Li, Jianyi
author_sort Lin, Lijun
collection PubMed
description BACKGROUND: The transoral atlantoaxial reduction plate (TARP) is an effective advance in the treatment of atlantoaxial dislocation (AAD) and can enable the performance of anterior atlantoaxial release, reduction, decompression, and internal fixation in a one-stage operation. However, accurate transoral C2 pedicle insertion (C2TOPI) remains a challenge. The aim of this study is to develop a grouped patient-specific drill template (PDT) specifically for AAD with complete reduction and, furthermore, to compare its efficacy and accuracy in facilitating C2TOPI. METHODS: After CT scanning, ten cadaveric C2 specimens were randomly assigned to two groups (the PDT and freehand group). A grouped PDT specifically for AAD with complete reduction was designed and manufactured. C2TOPI was performed using the PDT or the fluoroscopy-guided freehand technique. Postoperative CT scans were subsequently performed to analyze the deviations at the centroid of the cross section at the midpoint of the pedicle. Screw position grades were also assessed in both groups. RESULTS: Compared to the freehand group, the PDT group had a significantly shorter surgery time (p < 0.001). Significant differences between the two groups were observed in the absolute value of the deviations at the centroid of the pedicle on either the axial or sagittal planes (p < 0.05). No significant difference was found in the screw positions between the two groups (p > 0.05); however, two unacceptable breaches (20%) occurred in the freehand group. CONCLUSION: A specifically designed PDT could provide an accurate and easy-to-apply method for C2TOPI in AAD with complete reduction.
format Online
Article
Text
id pubmed-6524296
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-65242962019-05-24 Patient-specific drill template for C2 transoral pedicle insertion in complete reduction of atlantoaxial dislocation: cadaveric efficacy and accuracy assessments Lin, Lijun Zhu, Meisong Peng, Peng Zhang, Xintao Zhou, Xiaoqi Li, Jianyi J Orthop Surg Res Research Article BACKGROUND: The transoral atlantoaxial reduction plate (TARP) is an effective advance in the treatment of atlantoaxial dislocation (AAD) and can enable the performance of anterior atlantoaxial release, reduction, decompression, and internal fixation in a one-stage operation. However, accurate transoral C2 pedicle insertion (C2TOPI) remains a challenge. The aim of this study is to develop a grouped patient-specific drill template (PDT) specifically for AAD with complete reduction and, furthermore, to compare its efficacy and accuracy in facilitating C2TOPI. METHODS: After CT scanning, ten cadaveric C2 specimens were randomly assigned to two groups (the PDT and freehand group). A grouped PDT specifically for AAD with complete reduction was designed and manufactured. C2TOPI was performed using the PDT or the fluoroscopy-guided freehand technique. Postoperative CT scans were subsequently performed to analyze the deviations at the centroid of the cross section at the midpoint of the pedicle. Screw position grades were also assessed in both groups. RESULTS: Compared to the freehand group, the PDT group had a significantly shorter surgery time (p < 0.001). Significant differences between the two groups were observed in the absolute value of the deviations at the centroid of the pedicle on either the axial or sagittal planes (p < 0.05). No significant difference was found in the screw positions between the two groups (p > 0.05); however, two unacceptable breaches (20%) occurred in the freehand group. CONCLUSION: A specifically designed PDT could provide an accurate and easy-to-apply method for C2TOPI in AAD with complete reduction. BioMed Central 2019-05-16 /pmc/articles/PMC6524296/ /pubmed/31096990 http://dx.doi.org/10.1186/s13018-019-1189-7 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Lin, Lijun
Zhu, Meisong
Peng, Peng
Zhang, Xintao
Zhou, Xiaoqi
Li, Jianyi
Patient-specific drill template for C2 transoral pedicle insertion in complete reduction of atlantoaxial dislocation: cadaveric efficacy and accuracy assessments
title Patient-specific drill template for C2 transoral pedicle insertion in complete reduction of atlantoaxial dislocation: cadaveric efficacy and accuracy assessments
title_full Patient-specific drill template for C2 transoral pedicle insertion in complete reduction of atlantoaxial dislocation: cadaveric efficacy and accuracy assessments
title_fullStr Patient-specific drill template for C2 transoral pedicle insertion in complete reduction of atlantoaxial dislocation: cadaveric efficacy and accuracy assessments
title_full_unstemmed Patient-specific drill template for C2 transoral pedicle insertion in complete reduction of atlantoaxial dislocation: cadaveric efficacy and accuracy assessments
title_short Patient-specific drill template for C2 transoral pedicle insertion in complete reduction of atlantoaxial dislocation: cadaveric efficacy and accuracy assessments
title_sort patient-specific drill template for c2 transoral pedicle insertion in complete reduction of atlantoaxial dislocation: cadaveric efficacy and accuracy assessments
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6524296/
https://www.ncbi.nlm.nih.gov/pubmed/31096990
http://dx.doi.org/10.1186/s13018-019-1189-7
work_keys_str_mv AT linlijun patientspecificdrilltemplateforc2transoralpedicleinsertionincompletereductionofatlantoaxialdislocationcadavericefficacyandaccuracyassessments
AT zhumeisong patientspecificdrilltemplateforc2transoralpedicleinsertionincompletereductionofatlantoaxialdislocationcadavericefficacyandaccuracyassessments
AT pengpeng patientspecificdrilltemplateforc2transoralpedicleinsertionincompletereductionofatlantoaxialdislocationcadavericefficacyandaccuracyassessments
AT zhangxintao patientspecificdrilltemplateforc2transoralpedicleinsertionincompletereductionofatlantoaxialdislocationcadavericefficacyandaccuracyassessments
AT zhouxiaoqi patientspecificdrilltemplateforc2transoralpedicleinsertionincompletereductionofatlantoaxialdislocationcadavericefficacyandaccuracyassessments
AT lijianyi patientspecificdrilltemplateforc2transoralpedicleinsertionincompletereductionofatlantoaxialdislocationcadavericefficacyandaccuracyassessments