Cargando…
Face validity of a synthetic papilla designed for biliary sphincterotomy training
Background and study aims Endoscopic retrograde cholangiopancreatography (ERCP) is considered one of the most technically demanding endoscopic procedures. Still, limited data are available on simulators in ERCP training. Recently, the Boškoski-Costamagna ERCP Trainer was validated as a realistic tr...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
© Georg Thieme Verlag KG
2019
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6524995/ https://www.ncbi.nlm.nih.gov/pubmed/31157293 http://dx.doi.org/10.1055/a-0842-6369 |
_version_ | 1783419650558656512 |
---|---|
author | van der Wiel, Sophia E. Koch, Arjun D. Bruno, Marco J. |
author_facet | van der Wiel, Sophia E. Koch, Arjun D. Bruno, Marco J. |
author_sort | van der Wiel, Sophia E. |
collection | PubMed |
description | Background and study aims Endoscopic retrograde cholangiopancreatography (ERCP) is considered one of the most technically demanding endoscopic procedures. Still, limited data are available on simulators in ERCP training. Recently, the Boškoski-Costamagna ERCP Trainer was validated as a realistic training model by our study group. As an extension to this model, a novel synthetic papilla has been designed allowing to train biliary sphincterotomy. We aimed to determine the face validity of this synthetic papilla and its didactic value for training sphincterotomy. Methods Expert participants, each with more a than 2500 ERCPs lifetime experience, were invited to perform a biliary sphincterotomy and fill out a questionnaire on the realism of the procedure and the didactic value. Results A total of 40 ERCP experts were included, originating from 16 different countries. Experts’ opinion on realism of performing a biliary sphincterotomy was rated with a median of 7 on a 10-point Likert scale, resemblance of the performed maneuvers 8 and tactile feedback 7. When asked if the cutting was perceived as realistic, experts rated a 6 and the cutting result was rated 8. The potential of the cutting papilla as a training tool for novices was rated 4 on a 4-point scale and there was a high agreement among the experts to include the papilla in the training of novices (rating 4). Conclusion This is the first synthetic papilla available for training sphincterotomy on the Boškoski-Costamagna ERCP Trainer and it demonstrates good face validity. ERCP experts highly agree on its didactic value and added value in the training curriculum of novice endoscopists. |
format | Online Article Text |
id | pubmed-6524995 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | © Georg Thieme Verlag KG |
record_format | MEDLINE/PubMed |
spelling | pubmed-65249952019-06-01 Face validity of a synthetic papilla designed for biliary sphincterotomy training van der Wiel, Sophia E. Koch, Arjun D. Bruno, Marco J. Endosc Int Open Background and study aims Endoscopic retrograde cholangiopancreatography (ERCP) is considered one of the most technically demanding endoscopic procedures. Still, limited data are available on simulators in ERCP training. Recently, the Boškoski-Costamagna ERCP Trainer was validated as a realistic training model by our study group. As an extension to this model, a novel synthetic papilla has been designed allowing to train biliary sphincterotomy. We aimed to determine the face validity of this synthetic papilla and its didactic value for training sphincterotomy. Methods Expert participants, each with more a than 2500 ERCPs lifetime experience, were invited to perform a biliary sphincterotomy and fill out a questionnaire on the realism of the procedure and the didactic value. Results A total of 40 ERCP experts were included, originating from 16 different countries. Experts’ opinion on realism of performing a biliary sphincterotomy was rated with a median of 7 on a 10-point Likert scale, resemblance of the performed maneuvers 8 and tactile feedback 7. When asked if the cutting was perceived as realistic, experts rated a 6 and the cutting result was rated 8. The potential of the cutting papilla as a training tool for novices was rated 4 on a 4-point scale and there was a high agreement among the experts to include the papilla in the training of novices (rating 4). Conclusion This is the first synthetic papilla available for training sphincterotomy on the Boškoski-Costamagna ERCP Trainer and it demonstrates good face validity. ERCP experts highly agree on its didactic value and added value in the training curriculum of novice endoscopists. © Georg Thieme Verlag KG 2019-06 2019-05-17 /pmc/articles/PMC6524995/ /pubmed/31157293 http://dx.doi.org/10.1055/a-0842-6369 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited. |
spellingShingle | van der Wiel, Sophia E. Koch, Arjun D. Bruno, Marco J. Face validity of a synthetic papilla designed for biliary sphincterotomy training |
title | Face validity of a synthetic papilla designed for biliary sphincterotomy training |
title_full | Face validity of a synthetic papilla designed for biliary sphincterotomy training |
title_fullStr | Face validity of a synthetic papilla designed for biliary sphincterotomy training |
title_full_unstemmed | Face validity of a synthetic papilla designed for biliary sphincterotomy training |
title_short | Face validity of a synthetic papilla designed for biliary sphincterotomy training |
title_sort | face validity of a synthetic papilla designed for biliary sphincterotomy training |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6524995/ https://www.ncbi.nlm.nih.gov/pubmed/31157293 http://dx.doi.org/10.1055/a-0842-6369 |
work_keys_str_mv | AT vanderwielsophiae facevalidityofasyntheticpapilladesignedforbiliarysphincterotomytraining AT kocharjund facevalidityofasyntheticpapilladesignedforbiliarysphincterotomytraining AT brunomarcoj facevalidityofasyntheticpapilladesignedforbiliarysphincterotomytraining |