Electroretinograms before and after extraction of large intraocular iron foreign body

PURPOSE: We present our findings in a case with an intraocular foreign body in which the electroretinographic (ERG) findings were useful. OBSERVATIONS: A 37-year-old man was injured by an iron fragment that penetrated into his left eye through the cornea. His visual acuity was counting fingers, and...

Descripción completa

Detalles Bibliográficos
Autores principales: Kumagai, Tomoyuki, Matsumoto, Celso Soiti, Kimura, Itaru, Shinoda, Kei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6525325/
https://www.ncbi.nlm.nih.gov/pubmed/31193312
http://dx.doi.org/10.1016/j.ajoc.2019.100463
_version_ 1783419704757452800
author Kumagai, Tomoyuki
Matsumoto, Celso Soiti
Kimura, Itaru
Shinoda, Kei
author_facet Kumagai, Tomoyuki
Matsumoto, Celso Soiti
Kimura, Itaru
Shinoda, Kei
author_sort Kumagai, Tomoyuki
collection PubMed
description PURPOSE: We present our findings in a case with an intraocular foreign body in which the electroretinographic (ERG) findings were useful. OBSERVATIONS: A 37-year-old man was injured by an iron fragment that penetrated into his left eye through the cornea. His visual acuity was counting fingers, and a traumatic cataract prevented an examination of the fundus. B-mode ultrasonography showed a stick-like foreign body of approximately 14 mm in length in the eye. Preoperative ERGs with a contact lens electrode showed reduced responses with many blinking artifacts. Lensectomy and pars plana vitrectomy were performed and a fragment of a wire brush was seen embedded in the superior nasal retina which was removed. The decimal visual acuity improved to 1.2 two weeks later. The postoperative ERG performed with a skin electrode showed reduced responses in the injured eye. CONCLUSIONS AND IMPORTANCE: We recommend that the physiology of the retina be assessed by recording ERGs with a skin-type electrode as soon as possible after a traumatic injury to the eye.
format Online
Article
Text
id pubmed-6525325
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-65253252019-05-28 Electroretinograms before and after extraction of large intraocular iron foreign body Kumagai, Tomoyuki Matsumoto, Celso Soiti Kimura, Itaru Shinoda, Kei Am J Ophthalmol Case Rep Case Report PURPOSE: We present our findings in a case with an intraocular foreign body in which the electroretinographic (ERG) findings were useful. OBSERVATIONS: A 37-year-old man was injured by an iron fragment that penetrated into his left eye through the cornea. His visual acuity was counting fingers, and a traumatic cataract prevented an examination of the fundus. B-mode ultrasonography showed a stick-like foreign body of approximately 14 mm in length in the eye. Preoperative ERGs with a contact lens electrode showed reduced responses with many blinking artifacts. Lensectomy and pars plana vitrectomy were performed and a fragment of a wire brush was seen embedded in the superior nasal retina which was removed. The decimal visual acuity improved to 1.2 two weeks later. The postoperative ERG performed with a skin electrode showed reduced responses in the injured eye. CONCLUSIONS AND IMPORTANCE: We recommend that the physiology of the retina be assessed by recording ERGs with a skin-type electrode as soon as possible after a traumatic injury to the eye. Elsevier 2019-05-09 /pmc/articles/PMC6525325/ /pubmed/31193312 http://dx.doi.org/10.1016/j.ajoc.2019.100463 Text en © 2019 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Kumagai, Tomoyuki
Matsumoto, Celso Soiti
Kimura, Itaru
Shinoda, Kei
Electroretinograms before and after extraction of large intraocular iron foreign body
title Electroretinograms before and after extraction of large intraocular iron foreign body
title_full Electroretinograms before and after extraction of large intraocular iron foreign body
title_fullStr Electroretinograms before and after extraction of large intraocular iron foreign body
title_full_unstemmed Electroretinograms before and after extraction of large intraocular iron foreign body
title_short Electroretinograms before and after extraction of large intraocular iron foreign body
title_sort electroretinograms before and after extraction of large intraocular iron foreign body
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6525325/
https://www.ncbi.nlm.nih.gov/pubmed/31193312
http://dx.doi.org/10.1016/j.ajoc.2019.100463
work_keys_str_mv AT kumagaitomoyuki electroretinogramsbeforeandafterextractionoflargeintraocularironforeignbody
AT matsumotocelsosoiti electroretinogramsbeforeandafterextractionoflargeintraocularironforeignbody
AT kimuraitaru electroretinogramsbeforeandafterextractionoflargeintraocularironforeignbody
AT shinodakei electroretinogramsbeforeandafterextractionoflargeintraocularironforeignbody