Cargando…
Electroretinograms before and after extraction of large intraocular iron foreign body
PURPOSE: We present our findings in a case with an intraocular foreign body in which the electroretinographic (ERG) findings were useful. OBSERVATIONS: A 37-year-old man was injured by an iron fragment that penetrated into his left eye through the cornea. His visual acuity was counting fingers, and...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6525325/ https://www.ncbi.nlm.nih.gov/pubmed/31193312 http://dx.doi.org/10.1016/j.ajoc.2019.100463 |
_version_ | 1783419704757452800 |
---|---|
author | Kumagai, Tomoyuki Matsumoto, Celso Soiti Kimura, Itaru Shinoda, Kei |
author_facet | Kumagai, Tomoyuki Matsumoto, Celso Soiti Kimura, Itaru Shinoda, Kei |
author_sort | Kumagai, Tomoyuki |
collection | PubMed |
description | PURPOSE: We present our findings in a case with an intraocular foreign body in which the electroretinographic (ERG) findings were useful. OBSERVATIONS: A 37-year-old man was injured by an iron fragment that penetrated into his left eye through the cornea. His visual acuity was counting fingers, and a traumatic cataract prevented an examination of the fundus. B-mode ultrasonography showed a stick-like foreign body of approximately 14 mm in length in the eye. Preoperative ERGs with a contact lens electrode showed reduced responses with many blinking artifacts. Lensectomy and pars plana vitrectomy were performed and a fragment of a wire brush was seen embedded in the superior nasal retina which was removed. The decimal visual acuity improved to 1.2 two weeks later. The postoperative ERG performed with a skin electrode showed reduced responses in the injured eye. CONCLUSIONS AND IMPORTANCE: We recommend that the physiology of the retina be assessed by recording ERGs with a skin-type electrode as soon as possible after a traumatic injury to the eye. |
format | Online Article Text |
id | pubmed-6525325 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-65253252019-05-28 Electroretinograms before and after extraction of large intraocular iron foreign body Kumagai, Tomoyuki Matsumoto, Celso Soiti Kimura, Itaru Shinoda, Kei Am J Ophthalmol Case Rep Case Report PURPOSE: We present our findings in a case with an intraocular foreign body in which the electroretinographic (ERG) findings were useful. OBSERVATIONS: A 37-year-old man was injured by an iron fragment that penetrated into his left eye through the cornea. His visual acuity was counting fingers, and a traumatic cataract prevented an examination of the fundus. B-mode ultrasonography showed a stick-like foreign body of approximately 14 mm in length in the eye. Preoperative ERGs with a contact lens electrode showed reduced responses with many blinking artifacts. Lensectomy and pars plana vitrectomy were performed and a fragment of a wire brush was seen embedded in the superior nasal retina which was removed. The decimal visual acuity improved to 1.2 two weeks later. The postoperative ERG performed with a skin electrode showed reduced responses in the injured eye. CONCLUSIONS AND IMPORTANCE: We recommend that the physiology of the retina be assessed by recording ERGs with a skin-type electrode as soon as possible after a traumatic injury to the eye. Elsevier 2019-05-09 /pmc/articles/PMC6525325/ /pubmed/31193312 http://dx.doi.org/10.1016/j.ajoc.2019.100463 Text en © 2019 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Kumagai, Tomoyuki Matsumoto, Celso Soiti Kimura, Itaru Shinoda, Kei Electroretinograms before and after extraction of large intraocular iron foreign body |
title | Electroretinograms before and after extraction of large intraocular iron foreign body |
title_full | Electroretinograms before and after extraction of large intraocular iron foreign body |
title_fullStr | Electroretinograms before and after extraction of large intraocular iron foreign body |
title_full_unstemmed | Electroretinograms before and after extraction of large intraocular iron foreign body |
title_short | Electroretinograms before and after extraction of large intraocular iron foreign body |
title_sort | electroretinograms before and after extraction of large intraocular iron foreign body |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6525325/ https://www.ncbi.nlm.nih.gov/pubmed/31193312 http://dx.doi.org/10.1016/j.ajoc.2019.100463 |
work_keys_str_mv | AT kumagaitomoyuki electroretinogramsbeforeandafterextractionoflargeintraocularironforeignbody AT matsumotocelsosoiti electroretinogramsbeforeandafterextractionoflargeintraocularironforeignbody AT kimuraitaru electroretinogramsbeforeandafterextractionoflargeintraocularironforeignbody AT shinodakei electroretinogramsbeforeandafterextractionoflargeintraocularironforeignbody |