Cargando…
Modified Tension Band Wiring Using FiberWire for Patellar Fractures
In comminuted patellar fractures, we performed modified tension band wiring using a FiberWire (Arthrex) instead of the conventional methods. From March 2016 to March 2018, 63 patients with patellar fractures who needed surgical treatment were treated with modified tension band wiring using two Kirsc...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Orthopaedic Association
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6526127/ https://www.ncbi.nlm.nih.gov/pubmed/31156779 http://dx.doi.org/10.4055/cios.2019.11.2.244 |
_version_ | 1783419830988177408 |
---|---|
author | Lee, Bong-Ju Chon, Jegyun Yoon, Ja-Yeong Jung, Deukhee |
author_facet | Lee, Bong-Ju Chon, Jegyun Yoon, Ja-Yeong Jung, Deukhee |
author_sort | Lee, Bong-Ju |
collection | PubMed |
description | In comminuted patellar fractures, we performed modified tension band wiring using a FiberWire (Arthrex) instead of the conventional methods. From March 2016 to March 2018, 63 patients with patellar fractures who needed surgical treatment were treated with modified tension band wiring using two Kirschner wires (K-wires) and FiberWire. We inserted two 1.6-mm K-wires perpendicular to the fracture line after accurate reduction. With the knee flexed over 90°, we sutured around the patella using a FiberWire. Visual analog scale score and Levack's score were improved postoperatively. The mean bone union time was 5.6 months. None of the patients had breakage of wires, and nonunion with deformity occurred in one patient. We think that our method can be easier to handle and reduce irritation or breakage of the wires than conventional methods. In addition, early rehabilitation can be allowed. Therefore, we suggest that this method could be a useful method for the treatment of patellar fractures. |
format | Online Article Text |
id | pubmed-6526127 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | The Korean Orthopaedic Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-65261272019-06-01 Modified Tension Band Wiring Using FiberWire for Patellar Fractures Lee, Bong-Ju Chon, Jegyun Yoon, Ja-Yeong Jung, Deukhee Clin Orthop Surg Technical Note In comminuted patellar fractures, we performed modified tension band wiring using a FiberWire (Arthrex) instead of the conventional methods. From March 2016 to March 2018, 63 patients with patellar fractures who needed surgical treatment were treated with modified tension band wiring using two Kirschner wires (K-wires) and FiberWire. We inserted two 1.6-mm K-wires perpendicular to the fracture line after accurate reduction. With the knee flexed over 90°, we sutured around the patella using a FiberWire. Visual analog scale score and Levack's score were improved postoperatively. The mean bone union time was 5.6 months. None of the patients had breakage of wires, and nonunion with deformity occurred in one patient. We think that our method can be easier to handle and reduce irritation or breakage of the wires than conventional methods. In addition, early rehabilitation can be allowed. Therefore, we suggest that this method could be a useful method for the treatment of patellar fractures. The Korean Orthopaedic Association 2019-06 2019-05-09 /pmc/articles/PMC6526127/ /pubmed/31156779 http://dx.doi.org/10.4055/cios.2019.11.2.244 Text en Copyright © 2019 by The Korean Orthopaedic Association http://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Technical Note Lee, Bong-Ju Chon, Jegyun Yoon, Ja-Yeong Jung, Deukhee Modified Tension Band Wiring Using FiberWire for Patellar Fractures |
title | Modified Tension Band Wiring Using FiberWire for Patellar Fractures |
title_full | Modified Tension Band Wiring Using FiberWire for Patellar Fractures |
title_fullStr | Modified Tension Band Wiring Using FiberWire for Patellar Fractures |
title_full_unstemmed | Modified Tension Band Wiring Using FiberWire for Patellar Fractures |
title_short | Modified Tension Band Wiring Using FiberWire for Patellar Fractures |
title_sort | modified tension band wiring using fiberwire for patellar fractures |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6526127/ https://www.ncbi.nlm.nih.gov/pubmed/31156779 http://dx.doi.org/10.4055/cios.2019.11.2.244 |
work_keys_str_mv | AT leebongju modifiedtensionbandwiringusingfiberwireforpatellarfractures AT chonjegyun modifiedtensionbandwiringusingfiberwireforpatellarfractures AT yoonjayeong modifiedtensionbandwiringusingfiberwireforpatellarfractures AT jungdeukhee modifiedtensionbandwiringusingfiberwireforpatellarfractures |