Cargando…

Modified Tension Band Wiring Using FiberWire for Patellar Fractures

In comminuted patellar fractures, we performed modified tension band wiring using a FiberWire (Arthrex) instead of the conventional methods. From March 2016 to March 2018, 63 patients with patellar fractures who needed surgical treatment were treated with modified tension band wiring using two Kirsc...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Bong-Ju, Chon, Jegyun, Yoon, Ja-Yeong, Jung, Deukhee
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Orthopaedic Association 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6526127/
https://www.ncbi.nlm.nih.gov/pubmed/31156779
http://dx.doi.org/10.4055/cios.2019.11.2.244
_version_ 1783419830988177408
author Lee, Bong-Ju
Chon, Jegyun
Yoon, Ja-Yeong
Jung, Deukhee
author_facet Lee, Bong-Ju
Chon, Jegyun
Yoon, Ja-Yeong
Jung, Deukhee
author_sort Lee, Bong-Ju
collection PubMed
description In comminuted patellar fractures, we performed modified tension band wiring using a FiberWire (Arthrex) instead of the conventional methods. From March 2016 to March 2018, 63 patients with patellar fractures who needed surgical treatment were treated with modified tension band wiring using two Kirschner wires (K-wires) and FiberWire. We inserted two 1.6-mm K-wires perpendicular to the fracture line after accurate reduction. With the knee flexed over 90°, we sutured around the patella using a FiberWire. Visual analog scale score and Levack's score were improved postoperatively. The mean bone union time was 5.6 months. None of the patients had breakage of wires, and nonunion with deformity occurred in one patient. We think that our method can be easier to handle and reduce irritation or breakage of the wires than conventional methods. In addition, early rehabilitation can be allowed. Therefore, we suggest that this method could be a useful method for the treatment of patellar fractures.
format Online
Article
Text
id pubmed-6526127
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Orthopaedic Association
record_format MEDLINE/PubMed
spelling pubmed-65261272019-06-01 Modified Tension Band Wiring Using FiberWire for Patellar Fractures Lee, Bong-Ju Chon, Jegyun Yoon, Ja-Yeong Jung, Deukhee Clin Orthop Surg Technical Note In comminuted patellar fractures, we performed modified tension band wiring using a FiberWire (Arthrex) instead of the conventional methods. From March 2016 to March 2018, 63 patients with patellar fractures who needed surgical treatment were treated with modified tension band wiring using two Kirschner wires (K-wires) and FiberWire. We inserted two 1.6-mm K-wires perpendicular to the fracture line after accurate reduction. With the knee flexed over 90°, we sutured around the patella using a FiberWire. Visual analog scale score and Levack's score were improved postoperatively. The mean bone union time was 5.6 months. None of the patients had breakage of wires, and nonunion with deformity occurred in one patient. We think that our method can be easier to handle and reduce irritation or breakage of the wires than conventional methods. In addition, early rehabilitation can be allowed. Therefore, we suggest that this method could be a useful method for the treatment of patellar fractures. The Korean Orthopaedic Association 2019-06 2019-05-09 /pmc/articles/PMC6526127/ /pubmed/31156779 http://dx.doi.org/10.4055/cios.2019.11.2.244 Text en Copyright © 2019 by The Korean Orthopaedic Association http://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Note
Lee, Bong-Ju
Chon, Jegyun
Yoon, Ja-Yeong
Jung, Deukhee
Modified Tension Band Wiring Using FiberWire for Patellar Fractures
title Modified Tension Band Wiring Using FiberWire for Patellar Fractures
title_full Modified Tension Band Wiring Using FiberWire for Patellar Fractures
title_fullStr Modified Tension Band Wiring Using FiberWire for Patellar Fractures
title_full_unstemmed Modified Tension Band Wiring Using FiberWire for Patellar Fractures
title_short Modified Tension Band Wiring Using FiberWire for Patellar Fractures
title_sort modified tension band wiring using fiberwire for patellar fractures
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6526127/
https://www.ncbi.nlm.nih.gov/pubmed/31156779
http://dx.doi.org/10.4055/cios.2019.11.2.244
work_keys_str_mv AT leebongju modifiedtensionbandwiringusingfiberwireforpatellarfractures
AT chonjegyun modifiedtensionbandwiringusingfiberwireforpatellarfractures
AT yoonjayeong modifiedtensionbandwiringusingfiberwireforpatellarfractures
AT jungdeukhee modifiedtensionbandwiringusingfiberwireforpatellarfractures