Exhaled contaminant concentration data in a hospital room influenced by external heat gains
A hospital room is simulated using two breathing thermal manikins representing a health worker (HW) and a patient in repose (PR). The PR exhales R134a simulating small exhaled particles (<5 μm) and the contaminant concentration around and in the inhalation of HW is measured during a period of 2 h...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6526287/ https://www.ncbi.nlm.nih.gov/pubmed/31193338 http://dx.doi.org/10.1016/j.dib.2019.103978 |
_version_ | 1783419870353817600 |
---|---|
author | Olmedo, Ines Berlanga, Felix A. Villafruela, Jose Manuel Ruiz de Adana, Manuel |
author_facet | Olmedo, Ines Berlanga, Felix A. Villafruela, Jose Manuel Ruiz de Adana, Manuel |
author_sort | Olmedo, Ines |
collection | PubMed |
description | A hospital room is simulated using two breathing thermal manikins representing a health worker (HW) and a patient in repose (PR). The PR exhales R134a simulating small exhaled particles (<5 μm) and the contaminant concentration around and in the inhalation of HW is measured during a period of 2 hours per experiment. The room is climatized to maintain constant air temperature values of 25 °C using two wall mounted grilles and two exhausts. The air change per hour (ACH) used varies from 6 to 12 in order to evaluate its influence on the dispersion of exhaled contaminants. An external heat gain is simulated by a radiant wall (RW) that is active or inactive during the experiments. When RW is active the external heat gain simulated is 39.7 W/m(2), which corresponds to a solar external radiation typical in many countries worldwide. The contaminant concentration is measured at different locations around HW and in the inhalation tube. The temperature gradient in the room is also measured along a vertical pole. The discussion of the results of the 16 experimental cases can be found in Ref. [1]. |
format | Online Article Text |
id | pubmed-6526287 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-65262872019-05-28 Exhaled contaminant concentration data in a hospital room influenced by external heat gains Olmedo, Ines Berlanga, Felix A. Villafruela, Jose Manuel Ruiz de Adana, Manuel Data Brief Engineering A hospital room is simulated using two breathing thermal manikins representing a health worker (HW) and a patient in repose (PR). The PR exhales R134a simulating small exhaled particles (<5 μm) and the contaminant concentration around and in the inhalation of HW is measured during a period of 2 hours per experiment. The room is climatized to maintain constant air temperature values of 25 °C using two wall mounted grilles and two exhausts. The air change per hour (ACH) used varies from 6 to 12 in order to evaluate its influence on the dispersion of exhaled contaminants. An external heat gain is simulated by a radiant wall (RW) that is active or inactive during the experiments. When RW is active the external heat gain simulated is 39.7 W/m(2), which corresponds to a solar external radiation typical in many countries worldwide. The contaminant concentration is measured at different locations around HW and in the inhalation tube. The temperature gradient in the room is also measured along a vertical pole. The discussion of the results of the 16 experimental cases can be found in Ref. [1]. Elsevier 2019-05-08 /pmc/articles/PMC6526287/ /pubmed/31193338 http://dx.doi.org/10.1016/j.dib.2019.103978 Text en © 2019 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Engineering Olmedo, Ines Berlanga, Felix A. Villafruela, Jose Manuel Ruiz de Adana, Manuel Exhaled contaminant concentration data in a hospital room influenced by external heat gains |
title | Exhaled contaminant concentration data in a hospital room influenced by external heat gains |
title_full | Exhaled contaminant concentration data in a hospital room influenced by external heat gains |
title_fullStr | Exhaled contaminant concentration data in a hospital room influenced by external heat gains |
title_full_unstemmed | Exhaled contaminant concentration data in a hospital room influenced by external heat gains |
title_short | Exhaled contaminant concentration data in a hospital room influenced by external heat gains |
title_sort | exhaled contaminant concentration data in a hospital room influenced by external heat gains |
topic | Engineering |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6526287/ https://www.ncbi.nlm.nih.gov/pubmed/31193338 http://dx.doi.org/10.1016/j.dib.2019.103978 |
work_keys_str_mv | AT olmedoines exhaledcontaminantconcentrationdatainahospitalroominfluencedbyexternalheatgains AT berlangafelixa exhaledcontaminantconcentrationdatainahospitalroominfluencedbyexternalheatgains AT villafruelajosemanuel exhaledcontaminantconcentrationdatainahospitalroominfluencedbyexternalheatgains AT ruizdeadanamanuel exhaledcontaminantconcentrationdatainahospitalroominfluencedbyexternalheatgains |