Accuracy of Customized Prefabricated Screw-Type Immediate Provisional Restorations after Single-Implant Placement

Limited evidence is available comparing the differences between pre-operative and post-operative 3D implant positions from the viewpoint of prosthetics. We aimed to investigate the differences between preplanned positions of virtual provisional restorations and their actual positions following fully...

Descripción completa

Detalles Bibliográficos
Autores principales: Oh, Kyung Chul, Kim, Jee-Hwan, Woo, Chang-Woo, Moon, Hong Seok
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6526473/
https://www.ncbi.nlm.nih.gov/pubmed/30978960
http://dx.doi.org/10.3390/jcm8040490
_version_ 1783419901921198080
author Oh, Kyung Chul
Kim, Jee-Hwan
Woo, Chang-Woo
Moon, Hong Seok
author_facet Oh, Kyung Chul
Kim, Jee-Hwan
Woo, Chang-Woo
Moon, Hong Seok
author_sort Oh, Kyung Chul
collection PubMed
description Limited evidence is available comparing the differences between pre-operative and post-operative 3D implant positions from the viewpoint of prosthetics. We aimed to investigate the differences between preplanned positions of virtual provisional restorations and their actual positions following fully guided single-implant placement. Ten maxillary typodonts with missing right central incisors were imaged using cone-beam computed tomography, and digital impressions were obtained using an intraoral scanner. These data were imported into implant-planning software, following which the provisional restorations were designed. After data superimposition, an appropriate implant position was determined, and a computer-assisted implant surgical guide was designed for each typodont. Orders generated from the implant-planning software were imported into relevant computer-aided design software to design the custom abutments. The abutments, provisional restorations, and surgical guides were fabricated, and each restoration was cemented to the corresponding abutments, generating a screw-type immediate provisional restoration. The implants were placed using the surgical guides, and the screw-type provisional restorations were engaged to the implants. The typodonts were then rescanned using the intraoral scanner. The restorations designed at the treatment planning stage were compared with those in the post-operative scan using metrology software. The angular deviation around the central axis of the implant was measured, and the differences in the crown position were converted to root mean square (RMS) values. The post-operative provisional restorations exhibited an absolute angular deviation of 6.94 ± 5.78° and an RMS value of 85.8 ± 20.2 µm when compared with their positions in the pre-operative stage. Within the limitations of the present in vitro study, the results highlight the potential application of customized prefabricated immediate provisional restorations after single-implant placement.
format Online
Article
Text
id pubmed-6526473
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-65264732019-05-31 Accuracy of Customized Prefabricated Screw-Type Immediate Provisional Restorations after Single-Implant Placement Oh, Kyung Chul Kim, Jee-Hwan Woo, Chang-Woo Moon, Hong Seok J Clin Med Article Limited evidence is available comparing the differences between pre-operative and post-operative 3D implant positions from the viewpoint of prosthetics. We aimed to investigate the differences between preplanned positions of virtual provisional restorations and their actual positions following fully guided single-implant placement. Ten maxillary typodonts with missing right central incisors were imaged using cone-beam computed tomography, and digital impressions were obtained using an intraoral scanner. These data were imported into implant-planning software, following which the provisional restorations were designed. After data superimposition, an appropriate implant position was determined, and a computer-assisted implant surgical guide was designed for each typodont. Orders generated from the implant-planning software were imported into relevant computer-aided design software to design the custom abutments. The abutments, provisional restorations, and surgical guides were fabricated, and each restoration was cemented to the corresponding abutments, generating a screw-type immediate provisional restoration. The implants were placed using the surgical guides, and the screw-type provisional restorations were engaged to the implants. The typodonts were then rescanned using the intraoral scanner. The restorations designed at the treatment planning stage were compared with those in the post-operative scan using metrology software. The angular deviation around the central axis of the implant was measured, and the differences in the crown position were converted to root mean square (RMS) values. The post-operative provisional restorations exhibited an absolute angular deviation of 6.94 ± 5.78° and an RMS value of 85.8 ± 20.2 µm when compared with their positions in the pre-operative stage. Within the limitations of the present in vitro study, the results highlight the potential application of customized prefabricated immediate provisional restorations after single-implant placement. MDPI 2019-04-11 /pmc/articles/PMC6526473/ /pubmed/30978960 http://dx.doi.org/10.3390/jcm8040490 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Oh, Kyung Chul
Kim, Jee-Hwan
Woo, Chang-Woo
Moon, Hong Seok
Accuracy of Customized Prefabricated Screw-Type Immediate Provisional Restorations after Single-Implant Placement
title Accuracy of Customized Prefabricated Screw-Type Immediate Provisional Restorations after Single-Implant Placement
title_full Accuracy of Customized Prefabricated Screw-Type Immediate Provisional Restorations after Single-Implant Placement
title_fullStr Accuracy of Customized Prefabricated Screw-Type Immediate Provisional Restorations after Single-Implant Placement
title_full_unstemmed Accuracy of Customized Prefabricated Screw-Type Immediate Provisional Restorations after Single-Implant Placement
title_short Accuracy of Customized Prefabricated Screw-Type Immediate Provisional Restorations after Single-Implant Placement
title_sort accuracy of customized prefabricated screw-type immediate provisional restorations after single-implant placement
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6526473/
https://www.ncbi.nlm.nih.gov/pubmed/30978960
http://dx.doi.org/10.3390/jcm8040490
work_keys_str_mv AT ohkyungchul accuracyofcustomizedprefabricatedscrewtypeimmediateprovisionalrestorationsaftersingleimplantplacement
AT kimjeehwan accuracyofcustomizedprefabricatedscrewtypeimmediateprovisionalrestorationsaftersingleimplantplacement
AT woochangwoo accuracyofcustomizedprefabricatedscrewtypeimmediateprovisionalrestorationsaftersingleimplantplacement
AT moonhongseok accuracyofcustomizedprefabricatedscrewtypeimmediateprovisionalrestorationsaftersingleimplantplacement