Cargando…
Accuracy of Customized Prefabricated Screw-Type Immediate Provisional Restorations after Single-Implant Placement
Limited evidence is available comparing the differences between pre-operative and post-operative 3D implant positions from the viewpoint of prosthetics. We aimed to investigate the differences between preplanned positions of virtual provisional restorations and their actual positions following fully...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6526473/ https://www.ncbi.nlm.nih.gov/pubmed/30978960 http://dx.doi.org/10.3390/jcm8040490 |
_version_ | 1783419901921198080 |
---|---|
author | Oh, Kyung Chul Kim, Jee-Hwan Woo, Chang-Woo Moon, Hong Seok |
author_facet | Oh, Kyung Chul Kim, Jee-Hwan Woo, Chang-Woo Moon, Hong Seok |
author_sort | Oh, Kyung Chul |
collection | PubMed |
description | Limited evidence is available comparing the differences between pre-operative and post-operative 3D implant positions from the viewpoint of prosthetics. We aimed to investigate the differences between preplanned positions of virtual provisional restorations and their actual positions following fully guided single-implant placement. Ten maxillary typodonts with missing right central incisors were imaged using cone-beam computed tomography, and digital impressions were obtained using an intraoral scanner. These data were imported into implant-planning software, following which the provisional restorations were designed. After data superimposition, an appropriate implant position was determined, and a computer-assisted implant surgical guide was designed for each typodont. Orders generated from the implant-planning software were imported into relevant computer-aided design software to design the custom abutments. The abutments, provisional restorations, and surgical guides were fabricated, and each restoration was cemented to the corresponding abutments, generating a screw-type immediate provisional restoration. The implants were placed using the surgical guides, and the screw-type provisional restorations were engaged to the implants. The typodonts were then rescanned using the intraoral scanner. The restorations designed at the treatment planning stage were compared with those in the post-operative scan using metrology software. The angular deviation around the central axis of the implant was measured, and the differences in the crown position were converted to root mean square (RMS) values. The post-operative provisional restorations exhibited an absolute angular deviation of 6.94 ± 5.78° and an RMS value of 85.8 ± 20.2 µm when compared with their positions in the pre-operative stage. Within the limitations of the present in vitro study, the results highlight the potential application of customized prefabricated immediate provisional restorations after single-implant placement. |
format | Online Article Text |
id | pubmed-6526473 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-65264732019-05-31 Accuracy of Customized Prefabricated Screw-Type Immediate Provisional Restorations after Single-Implant Placement Oh, Kyung Chul Kim, Jee-Hwan Woo, Chang-Woo Moon, Hong Seok J Clin Med Article Limited evidence is available comparing the differences between pre-operative and post-operative 3D implant positions from the viewpoint of prosthetics. We aimed to investigate the differences between preplanned positions of virtual provisional restorations and their actual positions following fully guided single-implant placement. Ten maxillary typodonts with missing right central incisors were imaged using cone-beam computed tomography, and digital impressions were obtained using an intraoral scanner. These data were imported into implant-planning software, following which the provisional restorations were designed. After data superimposition, an appropriate implant position was determined, and a computer-assisted implant surgical guide was designed for each typodont. Orders generated from the implant-planning software were imported into relevant computer-aided design software to design the custom abutments. The abutments, provisional restorations, and surgical guides were fabricated, and each restoration was cemented to the corresponding abutments, generating a screw-type immediate provisional restoration. The implants were placed using the surgical guides, and the screw-type provisional restorations were engaged to the implants. The typodonts were then rescanned using the intraoral scanner. The restorations designed at the treatment planning stage were compared with those in the post-operative scan using metrology software. The angular deviation around the central axis of the implant was measured, and the differences in the crown position were converted to root mean square (RMS) values. The post-operative provisional restorations exhibited an absolute angular deviation of 6.94 ± 5.78° and an RMS value of 85.8 ± 20.2 µm when compared with their positions in the pre-operative stage. Within the limitations of the present in vitro study, the results highlight the potential application of customized prefabricated immediate provisional restorations after single-implant placement. MDPI 2019-04-11 /pmc/articles/PMC6526473/ /pubmed/30978960 http://dx.doi.org/10.3390/jcm8040490 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Oh, Kyung Chul Kim, Jee-Hwan Woo, Chang-Woo Moon, Hong Seok Accuracy of Customized Prefabricated Screw-Type Immediate Provisional Restorations after Single-Implant Placement |
title | Accuracy of Customized Prefabricated Screw-Type Immediate Provisional Restorations after Single-Implant Placement |
title_full | Accuracy of Customized Prefabricated Screw-Type Immediate Provisional Restorations after Single-Implant Placement |
title_fullStr | Accuracy of Customized Prefabricated Screw-Type Immediate Provisional Restorations after Single-Implant Placement |
title_full_unstemmed | Accuracy of Customized Prefabricated Screw-Type Immediate Provisional Restorations after Single-Implant Placement |
title_short | Accuracy of Customized Prefabricated Screw-Type Immediate Provisional Restorations after Single-Implant Placement |
title_sort | accuracy of customized prefabricated screw-type immediate provisional restorations after single-implant placement |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6526473/ https://www.ncbi.nlm.nih.gov/pubmed/30978960 http://dx.doi.org/10.3390/jcm8040490 |
work_keys_str_mv | AT ohkyungchul accuracyofcustomizedprefabricatedscrewtypeimmediateprovisionalrestorationsaftersingleimplantplacement AT kimjeehwan accuracyofcustomizedprefabricatedscrewtypeimmediateprovisionalrestorationsaftersingleimplantplacement AT woochangwoo accuracyofcustomizedprefabricatedscrewtypeimmediateprovisionalrestorationsaftersingleimplantplacement AT moonhongseok accuracyofcustomizedprefabricatedscrewtypeimmediateprovisionalrestorationsaftersingleimplantplacement |