Cargando…
Relation of multicenter automatic defibrillator implantation trial implantable cardioverter-defibrillator score with long-term cardiovascular events in patients with implantable cardioverter-defibrillator
OBJECTIVE: To test the hypothesis that multicenter automatic defibrillator implantation trial (MADIT) - implantable cardioverter-defibrillator (ICD) scores predict replacement requirement and appropriate shock in a mixed population including both primary and secondary prevention and long-term advers...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Kare Publishing
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6526984/ https://www.ncbi.nlm.nih.gov/pubmed/31180377 http://dx.doi.org/10.14744/nci.2018.69335 |
_version_ | 1783419975219806208 |
---|---|
author | Uslu, Abdulkadir Dogan, Cem Duman, Hakan Tanboga, Ibrahim Halil Askin, Lutfu Sevimli, Serdar |
author_facet | Uslu, Abdulkadir Dogan, Cem Duman, Hakan Tanboga, Ibrahim Halil Askin, Lutfu Sevimli, Serdar |
author_sort | Uslu, Abdulkadir |
collection | PubMed |
description | OBJECTIVE: To test the hypothesis that multicenter automatic defibrillator implantation trial (MADIT) - implantable cardioverter-defibrillator (ICD) scores predict replacement requirement and appropriate shock in a mixed population including both primary and secondary prevention and long-term adverse cardiovascular events. METHODS: The study has a retrospective design. Patients who were implanted with ICD in the cardiology clinic of Atatürk University Faculty of Medicine between 2000 and 2013 were included in the study. For this purpose, 1394 patients who were implanted with a device in our clinic were reviewed. Then, those who were implanted with permanent pacemaker (n=1005), cardiac resynchronization treatment (CRT) (n=45) and CRT-ICD (n=198) were excluded. RESULTS: A total of 146 patients (98 males, 67.1%) with a mean age of 61.1 (±14.8) years were recruited. The median follow-up time was 21.5 months (mean 30.6±25.9 months; minimum 4 months, and maximum 120 months). The median MADIT-ICD scores in the patients were 2. MADIT-ICD scores were categorized as low in 15.1%, intermediate in 57.5%, and high score in 27.4% of patients. Accordingly, MADIT-ICD scores (1.29 [1.00–1.68], p=0.050), hemoglobin (0.86 [0.75–0.99], p=0.047), and left ventricular ejection fraction (EF) (0.97 [0.94–0.99], p=0.023) were determined as independent predictors of major adverse cardiovascular events in the long-term follow-up of ICD-implanted population. CONCLUSION: In this study, we showed that there was an independent association of long-term adverse cardiovascular events with MADIT-ICD score, hemoglobin, and EF in patients implanted with ICD. |
format | Online Article Text |
id | pubmed-6526984 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Kare Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-65269842019-06-06 Relation of multicenter automatic defibrillator implantation trial implantable cardioverter-defibrillator score with long-term cardiovascular events in patients with implantable cardioverter-defibrillator Uslu, Abdulkadir Dogan, Cem Duman, Hakan Tanboga, Ibrahim Halil Askin, Lutfu Sevimli, Serdar North Clin Istanb Original Article OBJECTIVE: To test the hypothesis that multicenter automatic defibrillator implantation trial (MADIT) - implantable cardioverter-defibrillator (ICD) scores predict replacement requirement and appropriate shock in a mixed population including both primary and secondary prevention and long-term adverse cardiovascular events. METHODS: The study has a retrospective design. Patients who were implanted with ICD in the cardiology clinic of Atatürk University Faculty of Medicine between 2000 and 2013 were included in the study. For this purpose, 1394 patients who were implanted with a device in our clinic were reviewed. Then, those who were implanted with permanent pacemaker (n=1005), cardiac resynchronization treatment (CRT) (n=45) and CRT-ICD (n=198) were excluded. RESULTS: A total of 146 patients (98 males, 67.1%) with a mean age of 61.1 (±14.8) years were recruited. The median follow-up time was 21.5 months (mean 30.6±25.9 months; minimum 4 months, and maximum 120 months). The median MADIT-ICD scores in the patients were 2. MADIT-ICD scores were categorized as low in 15.1%, intermediate in 57.5%, and high score in 27.4% of patients. Accordingly, MADIT-ICD scores (1.29 [1.00–1.68], p=0.050), hemoglobin (0.86 [0.75–0.99], p=0.047), and left ventricular ejection fraction (EF) (0.97 [0.94–0.99], p=0.023) were determined as independent predictors of major adverse cardiovascular events in the long-term follow-up of ICD-implanted population. CONCLUSION: In this study, we showed that there was an independent association of long-term adverse cardiovascular events with MADIT-ICD score, hemoglobin, and EF in patients implanted with ICD. Kare Publishing 2018-08-13 /pmc/articles/PMC6526984/ /pubmed/31180377 http://dx.doi.org/10.14744/nci.2018.69335 Text en Copyright: © 2019 by Istanbul Northern Anatolian Association of Public Hospitals http://creativecommons.org/licenses/by-nc-sa/4.0 This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License |
spellingShingle | Original Article Uslu, Abdulkadir Dogan, Cem Duman, Hakan Tanboga, Ibrahim Halil Askin, Lutfu Sevimli, Serdar Relation of multicenter automatic defibrillator implantation trial implantable cardioverter-defibrillator score with long-term cardiovascular events in patients with implantable cardioverter-defibrillator |
title | Relation of multicenter automatic defibrillator implantation trial implantable cardioverter-defibrillator score with long-term cardiovascular events in patients with implantable cardioverter-defibrillator |
title_full | Relation of multicenter automatic defibrillator implantation trial implantable cardioverter-defibrillator score with long-term cardiovascular events in patients with implantable cardioverter-defibrillator |
title_fullStr | Relation of multicenter automatic defibrillator implantation trial implantable cardioverter-defibrillator score with long-term cardiovascular events in patients with implantable cardioverter-defibrillator |
title_full_unstemmed | Relation of multicenter automatic defibrillator implantation trial implantable cardioverter-defibrillator score with long-term cardiovascular events in patients with implantable cardioverter-defibrillator |
title_short | Relation of multicenter automatic defibrillator implantation trial implantable cardioverter-defibrillator score with long-term cardiovascular events in patients with implantable cardioverter-defibrillator |
title_sort | relation of multicenter automatic defibrillator implantation trial implantable cardioverter-defibrillator score with long-term cardiovascular events in patients with implantable cardioverter-defibrillator |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6526984/ https://www.ncbi.nlm.nih.gov/pubmed/31180377 http://dx.doi.org/10.14744/nci.2018.69335 |
work_keys_str_mv | AT usluabdulkadir relationofmulticenterautomaticdefibrillatorimplantationtrialimplantablecardioverterdefibrillatorscorewithlongtermcardiovasculareventsinpatientswithimplantablecardioverterdefibrillator AT dogancem relationofmulticenterautomaticdefibrillatorimplantationtrialimplantablecardioverterdefibrillatorscorewithlongtermcardiovasculareventsinpatientswithimplantablecardioverterdefibrillator AT dumanhakan relationofmulticenterautomaticdefibrillatorimplantationtrialimplantablecardioverterdefibrillatorscorewithlongtermcardiovasculareventsinpatientswithimplantablecardioverterdefibrillator AT tanbogaibrahimhalil relationofmulticenterautomaticdefibrillatorimplantationtrialimplantablecardioverterdefibrillatorscorewithlongtermcardiovasculareventsinpatientswithimplantablecardioverterdefibrillator AT askinlutfu relationofmulticenterautomaticdefibrillatorimplantationtrialimplantablecardioverterdefibrillatorscorewithlongtermcardiovasculareventsinpatientswithimplantablecardioverterdefibrillator AT sevimliserdar relationofmulticenterautomaticdefibrillatorimplantationtrialimplantablecardioverterdefibrillatorscorewithlongtermcardiovasculareventsinpatientswithimplantablecardioverterdefibrillator |