Adaptation of a Mice Doppler Echocardiography Platform to Measure Cardiac Flow Velocities for Embryonic Chicken and Adult Zebrafish

Ultrasonography is the most widely used imaging technique in cardiovascular medicine. In this technique, a piezoelectric crystal produces, sends, and receives high frequency ultrasound waves to the body to create an image of internal organs. It enables practical real time visualization in a non-inva...

Descripción completa

Detalles Bibliográficos
Autores principales: Benslimane, Fatiha M., Alser, Maha, Zakaria, Zain Z., Sharma, Anju, Abdelrahman, Hana A., Yalcin, Huseyin C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6527763/
https://www.ncbi.nlm.nih.gov/pubmed/31139625
http://dx.doi.org/10.3389/fbioe.2019.00096
_version_ 1783420077573406720
author Benslimane, Fatiha M.
Alser, Maha
Zakaria, Zain Z.
Sharma, Anju
Abdelrahman, Hana A.
Yalcin, Huseyin C.
author_facet Benslimane, Fatiha M.
Alser, Maha
Zakaria, Zain Z.
Sharma, Anju
Abdelrahman, Hana A.
Yalcin, Huseyin C.
author_sort Benslimane, Fatiha M.
collection PubMed
description Ultrasonography is the most widely used imaging technique in cardiovascular medicine. In this technique, a piezoelectric crystal produces, sends, and receives high frequency ultrasound waves to the body to create an image of internal organs. It enables practical real time visualization in a non-invasive manner, making the modality especially useful to image dynamic cardiac structures. In the last few decades, echocardiography has been applied to in vivo cardiac disease models, mainly to rodents. While clinical echocardiography platforms can be used for relatively large animals such as pigs and rats, specialized systems are needed for smaller species. Theoretically, as the size of the imaged sample decreases, the frequency of the ultrasound transducer needed to image the sample increases. There are multiple modes of echocardiography imaging. In Doppler mode, erythrocytes blood flow velocities are measured from the frequency shift of the sent ultrasound waves compared to received echoes. Recorded data are then used to calculate cardiac function parameters such as cardiac output, as well as the hemodynamic shear stress levels in the heart and blood vessels. The multi-mode (i.e., b-mode, m-mode, Pulsed Doppler, Tissue Doppler, etc.) small animal ultrasound systems in the market can be used for most in vivo cardiac disease models including mice, embryonic chick and zebrafish. These systems are also associated with significant costs. Alternatively, there are more economical single-mode echocardiography platforms. However, these are originally built for mice studies and they need to be tested and evaluated for smaller experimental models. We recently adapted a mice Doppler echocardiography system to measure cardiac flow velocities for adult zebrafish and embryonic chicken. We successfully assessed cardiac function and hemodynamic shear stress for normal as well as for diseased embryonic chicken and zebrafish. In this paper, we will present our detailed protocols for Doppler flow measurements and further cardiac function analysis on these models using the setup. The protocols will involve detailed steps for animal stabilization, probe orientation for specific measurements, data acquisition, and data analysis. We believe this information will help cardiac researchers to establish similar echocardiography platforms in their labs in a practical and economical manner.
format Online
Article
Text
id pubmed-6527763
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-65277632019-05-28 Adaptation of a Mice Doppler Echocardiography Platform to Measure Cardiac Flow Velocities for Embryonic Chicken and Adult Zebrafish Benslimane, Fatiha M. Alser, Maha Zakaria, Zain Z. Sharma, Anju Abdelrahman, Hana A. Yalcin, Huseyin C. Front Bioeng Biotechnol Bioengineering and Biotechnology Ultrasonography is the most widely used imaging technique in cardiovascular medicine. In this technique, a piezoelectric crystal produces, sends, and receives high frequency ultrasound waves to the body to create an image of internal organs. It enables practical real time visualization in a non-invasive manner, making the modality especially useful to image dynamic cardiac structures. In the last few decades, echocardiography has been applied to in vivo cardiac disease models, mainly to rodents. While clinical echocardiography platforms can be used for relatively large animals such as pigs and rats, specialized systems are needed for smaller species. Theoretically, as the size of the imaged sample decreases, the frequency of the ultrasound transducer needed to image the sample increases. There are multiple modes of echocardiography imaging. In Doppler mode, erythrocytes blood flow velocities are measured from the frequency shift of the sent ultrasound waves compared to received echoes. Recorded data are then used to calculate cardiac function parameters such as cardiac output, as well as the hemodynamic shear stress levels in the heart and blood vessels. The multi-mode (i.e., b-mode, m-mode, Pulsed Doppler, Tissue Doppler, etc.) small animal ultrasound systems in the market can be used for most in vivo cardiac disease models including mice, embryonic chick and zebrafish. These systems are also associated with significant costs. Alternatively, there are more economical single-mode echocardiography platforms. However, these are originally built for mice studies and they need to be tested and evaluated for smaller experimental models. We recently adapted a mice Doppler echocardiography system to measure cardiac flow velocities for adult zebrafish and embryonic chicken. We successfully assessed cardiac function and hemodynamic shear stress for normal as well as for diseased embryonic chicken and zebrafish. In this paper, we will present our detailed protocols for Doppler flow measurements and further cardiac function analysis on these models using the setup. The protocols will involve detailed steps for animal stabilization, probe orientation for specific measurements, data acquisition, and data analysis. We believe this information will help cardiac researchers to establish similar echocardiography platforms in their labs in a practical and economical manner. Frontiers Media S.A. 2019-05-14 /pmc/articles/PMC6527763/ /pubmed/31139625 http://dx.doi.org/10.3389/fbioe.2019.00096 Text en Copyright © 2019 Benslimane, Alser, Zakaria, Sharma, Abdelrahman and Yalcin. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Benslimane, Fatiha M.
Alser, Maha
Zakaria, Zain Z.
Sharma, Anju
Abdelrahman, Hana A.
Yalcin, Huseyin C.
Adaptation of a Mice Doppler Echocardiography Platform to Measure Cardiac Flow Velocities for Embryonic Chicken and Adult Zebrafish
title Adaptation of a Mice Doppler Echocardiography Platform to Measure Cardiac Flow Velocities for Embryonic Chicken and Adult Zebrafish
title_full Adaptation of a Mice Doppler Echocardiography Platform to Measure Cardiac Flow Velocities for Embryonic Chicken and Adult Zebrafish
title_fullStr Adaptation of a Mice Doppler Echocardiography Platform to Measure Cardiac Flow Velocities for Embryonic Chicken and Adult Zebrafish
title_full_unstemmed Adaptation of a Mice Doppler Echocardiography Platform to Measure Cardiac Flow Velocities for Embryonic Chicken and Adult Zebrafish
title_short Adaptation of a Mice Doppler Echocardiography Platform to Measure Cardiac Flow Velocities for Embryonic Chicken and Adult Zebrafish
title_sort adaptation of a mice doppler echocardiography platform to measure cardiac flow velocities for embryonic chicken and adult zebrafish
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6527763/
https://www.ncbi.nlm.nih.gov/pubmed/31139625
http://dx.doi.org/10.3389/fbioe.2019.00096
work_keys_str_mv AT benslimanefatiham adaptationofamicedopplerechocardiographyplatformtomeasurecardiacflowvelocitiesforembryonicchickenandadultzebrafish
AT alsermaha adaptationofamicedopplerechocardiographyplatformtomeasurecardiacflowvelocitiesforembryonicchickenandadultzebrafish
AT zakariazainz adaptationofamicedopplerechocardiographyplatformtomeasurecardiacflowvelocitiesforembryonicchickenandadultzebrafish
AT sharmaanju adaptationofamicedopplerechocardiographyplatformtomeasurecardiacflowvelocitiesforembryonicchickenandadultzebrafish
AT abdelrahmanhanaa adaptationofamicedopplerechocardiographyplatformtomeasurecardiacflowvelocitiesforembryonicchickenandadultzebrafish
AT yalcinhuseyinc adaptationofamicedopplerechocardiographyplatformtomeasurecardiacflowvelocitiesforembryonicchickenandadultzebrafish