Cargando…

Radiation protection effect of mobile shield barrier for the medical personnel during endoscopic retrograde cholangiopancreatography: a quasi-experimental prospective study

OBJECTIVE: To investigate the effectiveness of radiation protection offered by a newly designed mobile shield barrier for medical personnel during endoscopic retrograde cholangiopancreatography (ERCP). DESIGN: Quasi-experimental prospective study. SETTING: ERCP procedures conducted between October 2...

Descripción completa

Detalles Bibliográficos
Autores principales: Chung, Kwang Hyun, Park, Young Sook, Ahn, Sang Bong, Son, Byoung Kwan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6527993/
https://www.ncbi.nlm.nih.gov/pubmed/30898834
http://dx.doi.org/10.1136/bmjopen-2018-027729
_version_ 1783420128285687808
author Chung, Kwang Hyun
Park, Young Sook
Ahn, Sang Bong
Son, Byoung Kwan
author_facet Chung, Kwang Hyun
Park, Young Sook
Ahn, Sang Bong
Son, Byoung Kwan
author_sort Chung, Kwang Hyun
collection PubMed
description OBJECTIVE: To investigate the effectiveness of radiation protection offered by a newly designed mobile shield barrier for medical personnel during endoscopic retrograde cholangiopancreatography (ERCP). DESIGN: Quasi-experimental prospective study. SETTING: ERCP procedures conducted between October 2016 and June 2017 at a single secondary referral hospital that performs approximately 250 therapeutic ERCP procedures annually. INTERVENTIONS: The mobile shield barrier was a custom-made 2 mm Pb shielding plate (width: 120 cm, height: 190 cm) with a 0.5 mm Pb window (width: 115 cm, height: 60 cm) on its upper part was used. Four wheels were attached to the bottom to allow easy moving. PRIMARY AND SECONDARY OUTCOME MEASURES: The radiation doses were measured during ERCP using personal thermoluminescence dosimetry (TLD) badges on both sides of the mobile shield barrier (patient’s side: TLD1 and medical staff’s side: TLD2). The radiation doses were also measured on the outer surface of the thyroid shield of the endoscopist (TLD3), and on the chest area inside the protective apron of the endoscopist (TLD4) and the main assistant (TLD5). The TLD was changed and reported once every 3 months. The radiation dose measured by TLD badges were compared. RESULTS: During the study period, a total of 128 ERCP procedures were performed. The mean fluoroscopy time per procedure was 244.9±257.0 s and the mean number of digital radiographs per procedure was 3.7±1.0. TLD1 (outside the barrier) had a mean radiation dose of 26.85±3.47 mSv and all the other TLDs (inside the barrier) had less than 1 mSv (p<0.001). In the post hoc analysis, the difference between TLD1 and others showed a statistical significance; however, there were no significant differences between the TLDs inside the barrier. CONCLUSION: Our mobile shield barrier was useful to reduce the radiation exposure of medical personnel during ERCP.
format Online
Article
Text
id pubmed-6527993
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-65279932019-05-21 Radiation protection effect of mobile shield barrier for the medical personnel during endoscopic retrograde cholangiopancreatography: a quasi-experimental prospective study Chung, Kwang Hyun Park, Young Sook Ahn, Sang Bong Son, Byoung Kwan BMJ Open Gastroenterology and Hepatology OBJECTIVE: To investigate the effectiveness of radiation protection offered by a newly designed mobile shield barrier for medical personnel during endoscopic retrograde cholangiopancreatography (ERCP). DESIGN: Quasi-experimental prospective study. SETTING: ERCP procedures conducted between October 2016 and June 2017 at a single secondary referral hospital that performs approximately 250 therapeutic ERCP procedures annually. INTERVENTIONS: The mobile shield barrier was a custom-made 2 mm Pb shielding plate (width: 120 cm, height: 190 cm) with a 0.5 mm Pb window (width: 115 cm, height: 60 cm) on its upper part was used. Four wheels were attached to the bottom to allow easy moving. PRIMARY AND SECONDARY OUTCOME MEASURES: The radiation doses were measured during ERCP using personal thermoluminescence dosimetry (TLD) badges on both sides of the mobile shield barrier (patient’s side: TLD1 and medical staff’s side: TLD2). The radiation doses were also measured on the outer surface of the thyroid shield of the endoscopist (TLD3), and on the chest area inside the protective apron of the endoscopist (TLD4) and the main assistant (TLD5). The TLD was changed and reported once every 3 months. The radiation dose measured by TLD badges were compared. RESULTS: During the study period, a total of 128 ERCP procedures were performed. The mean fluoroscopy time per procedure was 244.9±257.0 s and the mean number of digital radiographs per procedure was 3.7±1.0. TLD1 (outside the barrier) had a mean radiation dose of 26.85±3.47 mSv and all the other TLDs (inside the barrier) had less than 1 mSv (p<0.001). In the post hoc analysis, the difference between TLD1 and others showed a statistical significance; however, there were no significant differences between the TLDs inside the barrier. CONCLUSION: Our mobile shield barrier was useful to reduce the radiation exposure of medical personnel during ERCP. BMJ Publishing Group 2019-03-20 /pmc/articles/PMC6527993/ /pubmed/30898834 http://dx.doi.org/10.1136/bmjopen-2018-027729 Text en © Author(s) (or their employer(s)) 2019. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.
spellingShingle Gastroenterology and Hepatology
Chung, Kwang Hyun
Park, Young Sook
Ahn, Sang Bong
Son, Byoung Kwan
Radiation protection effect of mobile shield barrier for the medical personnel during endoscopic retrograde cholangiopancreatography: a quasi-experimental prospective study
title Radiation protection effect of mobile shield barrier for the medical personnel during endoscopic retrograde cholangiopancreatography: a quasi-experimental prospective study
title_full Radiation protection effect of mobile shield barrier for the medical personnel during endoscopic retrograde cholangiopancreatography: a quasi-experimental prospective study
title_fullStr Radiation protection effect of mobile shield barrier for the medical personnel during endoscopic retrograde cholangiopancreatography: a quasi-experimental prospective study
title_full_unstemmed Radiation protection effect of mobile shield barrier for the medical personnel during endoscopic retrograde cholangiopancreatography: a quasi-experimental prospective study
title_short Radiation protection effect of mobile shield barrier for the medical personnel during endoscopic retrograde cholangiopancreatography: a quasi-experimental prospective study
title_sort radiation protection effect of mobile shield barrier for the medical personnel during endoscopic retrograde cholangiopancreatography: a quasi-experimental prospective study
topic Gastroenterology and Hepatology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6527993/
https://www.ncbi.nlm.nih.gov/pubmed/30898834
http://dx.doi.org/10.1136/bmjopen-2018-027729
work_keys_str_mv AT chungkwanghyun radiationprotectioneffectofmobileshieldbarrierforthemedicalpersonnelduringendoscopicretrogradecholangiopancreatographyaquasiexperimentalprospectivestudy
AT parkyoungsook radiationprotectioneffectofmobileshieldbarrierforthemedicalpersonnelduringendoscopicretrogradecholangiopancreatographyaquasiexperimentalprospectivestudy
AT ahnsangbong radiationprotectioneffectofmobileshieldbarrierforthemedicalpersonnelduringendoscopicretrogradecholangiopancreatographyaquasiexperimentalprospectivestudy
AT sonbyoungkwan radiationprotectioneffectofmobileshieldbarrierforthemedicalpersonnelduringendoscopicretrogradecholangiopancreatographyaquasiexperimentalprospectivestudy