Cargando…
Ultrasonic strain elastography for detecting abnormalities in the supraspinatus tendon: an intra- and inter-rater reliability study
OBJECTIVES: The reliability of ultrasonic strain elastography (SEL) used to detect abnormalities in the supraspinatus tendon is unclear. Thus, the aim of this study was to investigate the reliability of SEL in the supraspinatus tendon. DESIGN: An intra-rater and inter-rater reliability study. SETTIN...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6527995/ https://www.ncbi.nlm.nih.gov/pubmed/31072860 http://dx.doi.org/10.1136/bmjopen-2018-027725 |
_version_ | 1783420128758595584 |
---|---|
author | Brage, K Hjarbaek, John Kjaer, Per Ingwersen, Kim G Juul-Kristensen, Birgit |
author_facet | Brage, K Hjarbaek, John Kjaer, Per Ingwersen, Kim G Juul-Kristensen, Birgit |
author_sort | Brage, K |
collection | PubMed |
description | OBJECTIVES: The reliability of ultrasonic strain elastography (SEL) used to detect abnormalities in the supraspinatus tendon is unclear. Thus, the aim of this study was to investigate the reliability of SEL in the supraspinatus tendon. DESIGN: An intra-rater and inter-rater reliability study. SETTING: A single-centre study conducted at the University of Southern Denmark. PARTICIPANTS: Twenty participants with shoulder pain and MRI-verified supraspinatus tendinosis and 20 asymptomatic participants (no MRI). PRIMARY AND SECONDARY OUTCOME MEASURES: Raw values (RAW) and ratios (deltoid muscle (DELT) and gel pad (GEL) as reference tissues) were calculated and mean values of measurements from three regions of the supraspinatus tendon were reported. Colour scale ratings and number of yellow/red lesions from the three areas were also included. RESULTS: Intra-rater reliability showed intraclass correlation coefficients (ICCs) for RAW, DELT and GEL: 0.97 (minimal detectable change (MDC): 0.28 (6.36% of the mean)), 0.89 (MDC: 2.91 (20.37%)) and 0.73 (MDC: 1.61 (58.82%)), respectively. The ICCs for inter-rater reliability were 0.89 (MDC: 0.47 (10.53%)), 0.78 (MDC: 3.69 (25.51%)) and 0.70 (MDC: 1.75 (62.63%)), respectively. For colour scale ratings, intra-rater reliability (linear weighted kappa) ranged from 0.76 to 0.79, with the inter-rater reliability from 0.71 to 0.81. For the number of lesions, intra-rater reliability ranged from 0.40 to 0.82 and inter-rater reliability from 0.24 to 0.67. CONCLUSIONS: Intra-rater and inter-rater reliability were excellent for raw values and for ratios with deltoid muscle as the reference tissue, and good for ratios with gel pad as the reference tissue. The reliability of colour scale ratings was substantial-to-almost perfect, and for the number of lesions fair-to-almost perfect. Although high reliability was found, validity and responsiveness of these elastographic methods needs further investigation. ETHICS APPROVAL: The study protocol was approved by the Ethics Committee for the Region of South Denmark (S-20160115) and reported to the Danish Data Protection Agency (2014-41-3266). |
format | Online Article Text |
id | pubmed-6527995 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-65279952019-06-05 Ultrasonic strain elastography for detecting abnormalities in the supraspinatus tendon: an intra- and inter-rater reliability study Brage, K Hjarbaek, John Kjaer, Per Ingwersen, Kim G Juul-Kristensen, Birgit BMJ Open Radiology and Imaging OBJECTIVES: The reliability of ultrasonic strain elastography (SEL) used to detect abnormalities in the supraspinatus tendon is unclear. Thus, the aim of this study was to investigate the reliability of SEL in the supraspinatus tendon. DESIGN: An intra-rater and inter-rater reliability study. SETTING: A single-centre study conducted at the University of Southern Denmark. PARTICIPANTS: Twenty participants with shoulder pain and MRI-verified supraspinatus tendinosis and 20 asymptomatic participants (no MRI). PRIMARY AND SECONDARY OUTCOME MEASURES: Raw values (RAW) and ratios (deltoid muscle (DELT) and gel pad (GEL) as reference tissues) were calculated and mean values of measurements from three regions of the supraspinatus tendon were reported. Colour scale ratings and number of yellow/red lesions from the three areas were also included. RESULTS: Intra-rater reliability showed intraclass correlation coefficients (ICCs) for RAW, DELT and GEL: 0.97 (minimal detectable change (MDC): 0.28 (6.36% of the mean)), 0.89 (MDC: 2.91 (20.37%)) and 0.73 (MDC: 1.61 (58.82%)), respectively. The ICCs for inter-rater reliability were 0.89 (MDC: 0.47 (10.53%)), 0.78 (MDC: 3.69 (25.51%)) and 0.70 (MDC: 1.75 (62.63%)), respectively. For colour scale ratings, intra-rater reliability (linear weighted kappa) ranged from 0.76 to 0.79, with the inter-rater reliability from 0.71 to 0.81. For the number of lesions, intra-rater reliability ranged from 0.40 to 0.82 and inter-rater reliability from 0.24 to 0.67. CONCLUSIONS: Intra-rater and inter-rater reliability were excellent for raw values and for ratios with deltoid muscle as the reference tissue, and good for ratios with gel pad as the reference tissue. The reliability of colour scale ratings was substantial-to-almost perfect, and for the number of lesions fair-to-almost perfect. Although high reliability was found, validity and responsiveness of these elastographic methods needs further investigation. ETHICS APPROVAL: The study protocol was approved by the Ethics Committee for the Region of South Denmark (S-20160115) and reported to the Danish Data Protection Agency (2014-41-3266). BMJ Publishing Group 2019-05-09 /pmc/articles/PMC6527995/ /pubmed/31072860 http://dx.doi.org/10.1136/bmjopen-2018-027725 Text en © Author(s) (or their employer(s)) 2019. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/. |
spellingShingle | Radiology and Imaging Brage, K Hjarbaek, John Kjaer, Per Ingwersen, Kim G Juul-Kristensen, Birgit Ultrasonic strain elastography for detecting abnormalities in the supraspinatus tendon: an intra- and inter-rater reliability study |
title | Ultrasonic strain elastography for detecting abnormalities in the supraspinatus tendon: an intra- and inter-rater reliability study |
title_full | Ultrasonic strain elastography for detecting abnormalities in the supraspinatus tendon: an intra- and inter-rater reliability study |
title_fullStr | Ultrasonic strain elastography for detecting abnormalities in the supraspinatus tendon: an intra- and inter-rater reliability study |
title_full_unstemmed | Ultrasonic strain elastography for detecting abnormalities in the supraspinatus tendon: an intra- and inter-rater reliability study |
title_short | Ultrasonic strain elastography for detecting abnormalities in the supraspinatus tendon: an intra- and inter-rater reliability study |
title_sort | ultrasonic strain elastography for detecting abnormalities in the supraspinatus tendon: an intra- and inter-rater reliability study |
topic | Radiology and Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6527995/ https://www.ncbi.nlm.nih.gov/pubmed/31072860 http://dx.doi.org/10.1136/bmjopen-2018-027725 |
work_keys_str_mv | AT bragek ultrasonicstrainelastographyfordetectingabnormalitiesinthesupraspinatustendonanintraandinterraterreliabilitystudy AT hjarbaekjohn ultrasonicstrainelastographyfordetectingabnormalitiesinthesupraspinatustendonanintraandinterraterreliabilitystudy AT kjaerper ultrasonicstrainelastographyfordetectingabnormalitiesinthesupraspinatustendonanintraandinterraterreliabilitystudy AT ingwersenkimg ultrasonicstrainelastographyfordetectingabnormalitiesinthesupraspinatustendonanintraandinterraterreliabilitystudy AT juulkristensenbirgit ultrasonicstrainelastographyfordetectingabnormalitiesinthesupraspinatustendonanintraandinterraterreliabilitystudy |