A review of functional slit lamp biomicroscopy
Functional slit lamp biomicroscopy (FSLB) is a novel device which consists of a traditional slit-lamp and a digital camera. It can quantitatively assess vessel diameter, blood flow velocity, and blood flow rate and can create noninvasive microvascular perfusion maps (nMPMs). At present, FSLB is main...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6528339/ https://www.ncbi.nlm.nih.gov/pubmed/31139665 http://dx.doi.org/10.1186/s40662-019-0140-7 |
_version_ | 1783420196504993792 |
---|---|
author | Shu, Xupeng Wang, Jianhua Hu, Liang |
author_facet | Shu, Xupeng Wang, Jianhua Hu, Liang |
author_sort | Shu, Xupeng |
collection | PubMed |
description | Functional slit lamp biomicroscopy (FSLB) is a novel device which consists of a traditional slit-lamp and a digital camera. It can quantitatively assess vessel diameter, blood flow velocity, and blood flow rate and can create noninvasive microvascular perfusion maps (nMPMs). At present, FSLB is mainly used in contact lens (CL) and dry eye disease (DED) studies to advance our understanding of ocular surface microcirculation. FSLB-derived blood flow and vessel density measures are significantly altered in CL wearers and DED patients compared to normal people. These subtle changes in the ocular surface microcirculation may contribute to the monitoring of potential diseases of the body and provide a new way to diagnose dry eye disease. Therefore, this may also indicate that FSLB can be more widely applied in the study of other diseases to reveal the relationship between changes in ocular surface microcirculation and systemic diseases. The purpose of this paper is to summarize the functions of FSLB and the related studies especially in CL and DED. |
format | Online Article Text |
id | pubmed-6528339 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-65283392019-05-28 A review of functional slit lamp biomicroscopy Shu, Xupeng Wang, Jianhua Hu, Liang Eye Vis (Lond) Review Functional slit lamp biomicroscopy (FSLB) is a novel device which consists of a traditional slit-lamp and a digital camera. It can quantitatively assess vessel diameter, blood flow velocity, and blood flow rate and can create noninvasive microvascular perfusion maps (nMPMs). At present, FSLB is mainly used in contact lens (CL) and dry eye disease (DED) studies to advance our understanding of ocular surface microcirculation. FSLB-derived blood flow and vessel density measures are significantly altered in CL wearers and DED patients compared to normal people. These subtle changes in the ocular surface microcirculation may contribute to the monitoring of potential diseases of the body and provide a new way to diagnose dry eye disease. Therefore, this may also indicate that FSLB can be more widely applied in the study of other diseases to reveal the relationship between changes in ocular surface microcirculation and systemic diseases. The purpose of this paper is to summarize the functions of FSLB and the related studies especially in CL and DED. BioMed Central 2019-05-21 /pmc/articles/PMC6528339/ /pubmed/31139665 http://dx.doi.org/10.1186/s40662-019-0140-7 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Review Shu, Xupeng Wang, Jianhua Hu, Liang A review of functional slit lamp biomicroscopy |
title | A review of functional slit lamp biomicroscopy |
title_full | A review of functional slit lamp biomicroscopy |
title_fullStr | A review of functional slit lamp biomicroscopy |
title_full_unstemmed | A review of functional slit lamp biomicroscopy |
title_short | A review of functional slit lamp biomicroscopy |
title_sort | review of functional slit lamp biomicroscopy |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6528339/ https://www.ncbi.nlm.nih.gov/pubmed/31139665 http://dx.doi.org/10.1186/s40662-019-0140-7 |
work_keys_str_mv | AT shuxupeng areviewoffunctionalslitlampbiomicroscopy AT wangjianhua areviewoffunctionalslitlampbiomicroscopy AT huliang areviewoffunctionalslitlampbiomicroscopy AT shuxupeng reviewoffunctionalslitlampbiomicroscopy AT wangjianhua reviewoffunctionalslitlampbiomicroscopy AT huliang reviewoffunctionalslitlampbiomicroscopy |