Cargando…

A review of functional slit lamp biomicroscopy

Functional slit lamp biomicroscopy (FSLB) is a novel device which consists of a traditional slit-lamp and a digital camera. It can quantitatively assess vessel diameter, blood flow velocity, and blood flow rate and can create noninvasive microvascular perfusion maps (nMPMs). At present, FSLB is main...

Descripción completa

Detalles Bibliográficos
Autores principales: Shu, Xupeng, Wang, Jianhua, Hu, Liang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6528339/
https://www.ncbi.nlm.nih.gov/pubmed/31139665
http://dx.doi.org/10.1186/s40662-019-0140-7
_version_ 1783420196504993792
author Shu, Xupeng
Wang, Jianhua
Hu, Liang
author_facet Shu, Xupeng
Wang, Jianhua
Hu, Liang
author_sort Shu, Xupeng
collection PubMed
description Functional slit lamp biomicroscopy (FSLB) is a novel device which consists of a traditional slit-lamp and a digital camera. It can quantitatively assess vessel diameter, blood flow velocity, and blood flow rate and can create noninvasive microvascular perfusion maps (nMPMs). At present, FSLB is mainly used in contact lens (CL) and dry eye disease (DED) studies to advance our understanding of ocular surface microcirculation. FSLB-derived blood flow and vessel density measures are significantly altered in CL wearers and DED patients compared to normal people. These subtle changes in the ocular surface microcirculation may contribute to the monitoring of potential diseases of the body and provide a new way to diagnose dry eye disease. Therefore, this may also indicate that FSLB can be more widely applied in the study of other diseases to reveal the relationship between changes in ocular surface microcirculation and systemic diseases. The purpose of this paper is to summarize the functions of FSLB and the related studies especially in CL and DED.
format Online
Article
Text
id pubmed-6528339
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-65283392019-05-28 A review of functional slit lamp biomicroscopy Shu, Xupeng Wang, Jianhua Hu, Liang Eye Vis (Lond) Review Functional slit lamp biomicroscopy (FSLB) is a novel device which consists of a traditional slit-lamp and a digital camera. It can quantitatively assess vessel diameter, blood flow velocity, and blood flow rate and can create noninvasive microvascular perfusion maps (nMPMs). At present, FSLB is mainly used in contact lens (CL) and dry eye disease (DED) studies to advance our understanding of ocular surface microcirculation. FSLB-derived blood flow and vessel density measures are significantly altered in CL wearers and DED patients compared to normal people. These subtle changes in the ocular surface microcirculation may contribute to the monitoring of potential diseases of the body and provide a new way to diagnose dry eye disease. Therefore, this may also indicate that FSLB can be more widely applied in the study of other diseases to reveal the relationship between changes in ocular surface microcirculation and systemic diseases. The purpose of this paper is to summarize the functions of FSLB and the related studies especially in CL and DED. BioMed Central 2019-05-21 /pmc/articles/PMC6528339/ /pubmed/31139665 http://dx.doi.org/10.1186/s40662-019-0140-7 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Review
Shu, Xupeng
Wang, Jianhua
Hu, Liang
A review of functional slit lamp biomicroscopy
title A review of functional slit lamp biomicroscopy
title_full A review of functional slit lamp biomicroscopy
title_fullStr A review of functional slit lamp biomicroscopy
title_full_unstemmed A review of functional slit lamp biomicroscopy
title_short A review of functional slit lamp biomicroscopy
title_sort review of functional slit lamp biomicroscopy
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6528339/
https://www.ncbi.nlm.nih.gov/pubmed/31139665
http://dx.doi.org/10.1186/s40662-019-0140-7
work_keys_str_mv AT shuxupeng areviewoffunctionalslitlampbiomicroscopy
AT wangjianhua areviewoffunctionalslitlampbiomicroscopy
AT huliang areviewoffunctionalslitlampbiomicroscopy
AT shuxupeng reviewoffunctionalslitlampbiomicroscopy
AT wangjianhua reviewoffunctionalslitlampbiomicroscopy
AT huliang reviewoffunctionalslitlampbiomicroscopy