Cargando…

Comprehensive echocardiographic imaging of atrioventricular valves in children with atrioventricular septal defect: Accuracy of 2D and 3D imaging and reasons for disagreement

OBJECTIVE: To compare the accuracy and reasons for disagreement of two-dimensional (2D) and three-dimensional (3D) echocardiography findings in the assessment of the atrioventricular valve complex in patients with atrioventricular septal defect. METHODS: A total of 20 children (mean age 8 months) wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Hakacova, Nina, Higgins, Thomas, Malm, Torsten, Wierup, Per, Maynard, Charles, Johansson, Jens Ramgren
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Kare Publishing 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6528495/
https://www.ncbi.nlm.nih.gov/pubmed/30930449
http://dx.doi.org/10.14744/AnatolJCardiol.2019.49376
_version_ 1783420226102099968
author Hakacova, Nina
Higgins, Thomas
Malm, Torsten
Wierup, Per
Maynard, Charles
Johansson, Jens Ramgren
author_facet Hakacova, Nina
Higgins, Thomas
Malm, Torsten
Wierup, Per
Maynard, Charles
Johansson, Jens Ramgren
author_sort Hakacova, Nina
collection PubMed
description OBJECTIVE: To compare the accuracy and reasons for disagreement of two-dimensional (2D) and three-dimensional (3D) echocardiography findings in the assessment of the atrioventricular valve complex in patients with atrioventricular septal defect. METHODS: A total of 20 children (mean age 8 months) with atrioventricular septal defect were enrolled prospectively into this study. The accuracy of and the reasons for disagreement in the assessment of the atrioventricular valve features were analyzed between 2D and 3D echocardiography and surgical findings. RESULTS: We found that in assessing the Rastelli type and the extension of the inferior leaflet into the right ventricle, 3D echocardiography was more accurate compared to 2D echocardiography. In all other features, 2D and 3D echocardiography showed similar accuracy. A significant reason for inaccuracy by both echo modalities was that the technique itself could not visualize the feature, although the image quality was considered to be adequate. In most cases, where it was not possible to visualize the atrioventricular feature by 2D, it was possible by 3D, and vice versa. CONCLUSION: The accuracy of 2D and 3D echocardiography and understanding the potential reasons for disagreements in assessing the atrioventricular valve complex with 2D and 3D can guide the use of those two techniques when combining them in the clinical practice.
format Online
Article
Text
id pubmed-6528495
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Kare Publishing
record_format MEDLINE/PubMed
spelling pubmed-65284952019-05-30 Comprehensive echocardiographic imaging of atrioventricular valves in children with atrioventricular septal defect: Accuracy of 2D and 3D imaging and reasons for disagreement Hakacova, Nina Higgins, Thomas Malm, Torsten Wierup, Per Maynard, Charles Johansson, Jens Ramgren Anatol J Cardiol Original Investigation OBJECTIVE: To compare the accuracy and reasons for disagreement of two-dimensional (2D) and three-dimensional (3D) echocardiography findings in the assessment of the atrioventricular valve complex in patients with atrioventricular septal defect. METHODS: A total of 20 children (mean age 8 months) with atrioventricular septal defect were enrolled prospectively into this study. The accuracy of and the reasons for disagreement in the assessment of the atrioventricular valve features were analyzed between 2D and 3D echocardiography and surgical findings. RESULTS: We found that in assessing the Rastelli type and the extension of the inferior leaflet into the right ventricle, 3D echocardiography was more accurate compared to 2D echocardiography. In all other features, 2D and 3D echocardiography showed similar accuracy. A significant reason for inaccuracy by both echo modalities was that the technique itself could not visualize the feature, although the image quality was considered to be adequate. In most cases, where it was not possible to visualize the atrioventricular feature by 2D, it was possible by 3D, and vice versa. CONCLUSION: The accuracy of 2D and 3D echocardiography and understanding the potential reasons for disagreements in assessing the atrioventricular valve complex with 2D and 3D can guide the use of those two techniques when combining them in the clinical practice. Kare Publishing 2019-05 2019-03-05 /pmc/articles/PMC6528495/ /pubmed/30930449 http://dx.doi.org/10.14744/AnatolJCardiol.2019.49376 Text en Copyright: © 2019 Turkish Society of Cardiology http://creativecommons.org/licenses/by-nc-sa/4.0 This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License
spellingShingle Original Investigation
Hakacova, Nina
Higgins, Thomas
Malm, Torsten
Wierup, Per
Maynard, Charles
Johansson, Jens Ramgren
Comprehensive echocardiographic imaging of atrioventricular valves in children with atrioventricular septal defect: Accuracy of 2D and 3D imaging and reasons for disagreement
title Comprehensive echocardiographic imaging of atrioventricular valves in children with atrioventricular septal defect: Accuracy of 2D and 3D imaging and reasons for disagreement
title_full Comprehensive echocardiographic imaging of atrioventricular valves in children with atrioventricular septal defect: Accuracy of 2D and 3D imaging and reasons for disagreement
title_fullStr Comprehensive echocardiographic imaging of atrioventricular valves in children with atrioventricular septal defect: Accuracy of 2D and 3D imaging and reasons for disagreement
title_full_unstemmed Comprehensive echocardiographic imaging of atrioventricular valves in children with atrioventricular septal defect: Accuracy of 2D and 3D imaging and reasons for disagreement
title_short Comprehensive echocardiographic imaging of atrioventricular valves in children with atrioventricular septal defect: Accuracy of 2D and 3D imaging and reasons for disagreement
title_sort comprehensive echocardiographic imaging of atrioventricular valves in children with atrioventricular septal defect: accuracy of 2d and 3d imaging and reasons for disagreement
topic Original Investigation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6528495/
https://www.ncbi.nlm.nih.gov/pubmed/30930449
http://dx.doi.org/10.14744/AnatolJCardiol.2019.49376
work_keys_str_mv AT hakacovanina comprehensiveechocardiographicimagingofatrioventricularvalvesinchildrenwithatrioventricularseptaldefectaccuracyof2dand3dimagingandreasonsfordisagreement
AT higginsthomas comprehensiveechocardiographicimagingofatrioventricularvalvesinchildrenwithatrioventricularseptaldefectaccuracyof2dand3dimagingandreasonsfordisagreement
AT malmtorsten comprehensiveechocardiographicimagingofatrioventricularvalvesinchildrenwithatrioventricularseptaldefectaccuracyof2dand3dimagingandreasonsfordisagreement
AT wierupper comprehensiveechocardiographicimagingofatrioventricularvalvesinchildrenwithatrioventricularseptaldefectaccuracyof2dand3dimagingandreasonsfordisagreement
AT maynardcharles comprehensiveechocardiographicimagingofatrioventricularvalvesinchildrenwithatrioventricularseptaldefectaccuracyof2dand3dimagingandreasonsfordisagreement
AT johanssonjensramgren comprehensiveechocardiographicimagingofatrioventricularvalvesinchildrenwithatrioventricularseptaldefectaccuracyof2dand3dimagingandreasonsfordisagreement