Cargando…
FLT3, a prognostic biomarker for acute myeloid leukemia (AML): Quantitative monitoring with a simple anti‐FLT3 interaction and flow cytometric method
BACKGROUND: Overexpression of fms‐like tyrosine kinase 3 (FLT3) protein in leukemia is highly related to poor prognosis and reduced survival rate in acute myeloid leukemia (AML) and acute lymphoblastic leukemia (ALL) patients. Simple but efficient quantification of FLT3 protein levels on the leukemi...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6528579/ https://www.ncbi.nlm.nih.gov/pubmed/30737839 http://dx.doi.org/10.1002/jcla.22859 |
_version_ | 1783420250737344512 |
---|---|
author | Ampasavate, Chadarat Jutapakdee, Wasimon Phongpradist, Rungsinee Tima, Singkome Tantiworawit, Adisak Charoenkwan, Pimlak Chinwong, Dujrudee Anuchapreeda, Songyot |
author_facet | Ampasavate, Chadarat Jutapakdee, Wasimon Phongpradist, Rungsinee Tima, Singkome Tantiworawit, Adisak Charoenkwan, Pimlak Chinwong, Dujrudee Anuchapreeda, Songyot |
author_sort | Ampasavate, Chadarat |
collection | PubMed |
description | BACKGROUND: Overexpression of fms‐like tyrosine kinase 3 (FLT3) protein in leukemia is highly related to poor prognosis and reduced survival rate in acute myeloid leukemia (AML) and acute lymphoblastic leukemia (ALL) patients. Simple but efficient quantification of FLT3 protein levels on the leukemic cell surface using flow cytometry had been developed for rapid determination of FLT3 on intact cell surface. METHODS: Quantitation protocol for FLT3 biomarker in clinical samples was developed and validated. Cell model selection for calibration curve construction was identified and evaluated. Selected antibody concentrations, cell density, and incubation time were evaluated for most appropriate conditions. Comparison of the developed FLT3 determination protocol with the conventional Western blot analysis was performed. RESULTS: EoL‐1 cell line was selected for using as positive control cells. Calibration curve (20%‐120% of FLT3 positive cells) and quality control (QC) levels were constructed and evaluated. The results demonstrated good linearity (r (2) > 0.99). The intra‐ and inter‐day precision and accuracy, expressed as the coefficient of variation (%CV) and % recovery, were <20% and fell in 80%‐120% in all cases. When compared with Western blotting results, FLT3 protein expression levels in leukemia patient's bone marrow samples were demonstrated in the same trend. CONCLUSIONS: The effective, reliable, rapid, and economical analytical technique using the developed flow cytometric method was demonstrated for FLT3 protein determination on leukemic cell surface. This method provided a practical analysis of FLT‐3 biomarker levels which is valuable for physician decision in acute leukemia treatment. |
format | Online Article Text |
id | pubmed-6528579 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-65285792019-11-12 FLT3, a prognostic biomarker for acute myeloid leukemia (AML): Quantitative monitoring with a simple anti‐FLT3 interaction and flow cytometric method Ampasavate, Chadarat Jutapakdee, Wasimon Phongpradist, Rungsinee Tima, Singkome Tantiworawit, Adisak Charoenkwan, Pimlak Chinwong, Dujrudee Anuchapreeda, Songyot J Clin Lab Anal Research Articles BACKGROUND: Overexpression of fms‐like tyrosine kinase 3 (FLT3) protein in leukemia is highly related to poor prognosis and reduced survival rate in acute myeloid leukemia (AML) and acute lymphoblastic leukemia (ALL) patients. Simple but efficient quantification of FLT3 protein levels on the leukemic cell surface using flow cytometry had been developed for rapid determination of FLT3 on intact cell surface. METHODS: Quantitation protocol for FLT3 biomarker in clinical samples was developed and validated. Cell model selection for calibration curve construction was identified and evaluated. Selected antibody concentrations, cell density, and incubation time were evaluated for most appropriate conditions. Comparison of the developed FLT3 determination protocol with the conventional Western blot analysis was performed. RESULTS: EoL‐1 cell line was selected for using as positive control cells. Calibration curve (20%‐120% of FLT3 positive cells) and quality control (QC) levels were constructed and evaluated. The results demonstrated good linearity (r (2) > 0.99). The intra‐ and inter‐day precision and accuracy, expressed as the coefficient of variation (%CV) and % recovery, were <20% and fell in 80%‐120% in all cases. When compared with Western blotting results, FLT3 protein expression levels in leukemia patient's bone marrow samples were demonstrated in the same trend. CONCLUSIONS: The effective, reliable, rapid, and economical analytical technique using the developed flow cytometric method was demonstrated for FLT3 protein determination on leukemic cell surface. This method provided a practical analysis of FLT‐3 biomarker levels which is valuable for physician decision in acute leukemia treatment. John Wiley and Sons Inc. 2019-02-08 /pmc/articles/PMC6528579/ /pubmed/30737839 http://dx.doi.org/10.1002/jcla.22859 Text en © 2019 The Authors. Journal of Clinical Laboratory Analysis Published by Wiley Periodicals, Inc. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | Research Articles Ampasavate, Chadarat Jutapakdee, Wasimon Phongpradist, Rungsinee Tima, Singkome Tantiworawit, Adisak Charoenkwan, Pimlak Chinwong, Dujrudee Anuchapreeda, Songyot FLT3, a prognostic biomarker for acute myeloid leukemia (AML): Quantitative monitoring with a simple anti‐FLT3 interaction and flow cytometric method |
title | FLT3, a prognostic biomarker for acute myeloid leukemia (AML): Quantitative monitoring with a simple anti‐FLT3 interaction and flow cytometric method |
title_full | FLT3, a prognostic biomarker for acute myeloid leukemia (AML): Quantitative monitoring with a simple anti‐FLT3 interaction and flow cytometric method |
title_fullStr | FLT3, a prognostic biomarker for acute myeloid leukemia (AML): Quantitative monitoring with a simple anti‐FLT3 interaction and flow cytometric method |
title_full_unstemmed | FLT3, a prognostic biomarker for acute myeloid leukemia (AML): Quantitative monitoring with a simple anti‐FLT3 interaction and flow cytometric method |
title_short | FLT3, a prognostic biomarker for acute myeloid leukemia (AML): Quantitative monitoring with a simple anti‐FLT3 interaction and flow cytometric method |
title_sort | flt3, a prognostic biomarker for acute myeloid leukemia (aml): quantitative monitoring with a simple anti‐flt3 interaction and flow cytometric method |
topic | Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6528579/ https://www.ncbi.nlm.nih.gov/pubmed/30737839 http://dx.doi.org/10.1002/jcla.22859 |
work_keys_str_mv | AT ampasavatechadarat flt3aprognosticbiomarkerforacutemyeloidleukemiaamlquantitativemonitoringwithasimpleantiflt3interactionandflowcytometricmethod AT jutapakdeewasimon flt3aprognosticbiomarkerforacutemyeloidleukemiaamlquantitativemonitoringwithasimpleantiflt3interactionandflowcytometricmethod AT phongpradistrungsinee flt3aprognosticbiomarkerforacutemyeloidleukemiaamlquantitativemonitoringwithasimpleantiflt3interactionandflowcytometricmethod AT timasingkome flt3aprognosticbiomarkerforacutemyeloidleukemiaamlquantitativemonitoringwithasimpleantiflt3interactionandflowcytometricmethod AT tantiworawitadisak flt3aprognosticbiomarkerforacutemyeloidleukemiaamlquantitativemonitoringwithasimpleantiflt3interactionandflowcytometricmethod AT charoenkwanpimlak flt3aprognosticbiomarkerforacutemyeloidleukemiaamlquantitativemonitoringwithasimpleantiflt3interactionandflowcytometricmethod AT chinwongdujrudee flt3aprognosticbiomarkerforacutemyeloidleukemiaamlquantitativemonitoringwithasimpleantiflt3interactionandflowcytometricmethod AT anuchapreedasongyot flt3aprognosticbiomarkerforacutemyeloidleukemiaamlquantitativemonitoringwithasimpleantiflt3interactionandflowcytometricmethod |