Cargando…

Valgus osteotomy in delayed presentation of femoral neck fractures using fixed angle simple dynamic hip screw and plate

PURPOSE: Reduction and fixation in femoral neck fracture in young patients have a problem of nonunion, requiring additional procedures like valgus osteotomy; but fixation devices are technically difficult for inexperienced surgeons. We aims to assess the results of valgus osteotomy in femoral neck f...

Descripción completa

Detalles Bibliográficos
Autores principales: Nayak, Chandrakant, Acharyya, Biplab, Jain, Mantu, Kamboj, Kulbhushan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6529366/
https://www.ncbi.nlm.nih.gov/pubmed/30824174
http://dx.doi.org/10.1016/j.cjtee.2018.12.003
_version_ 1783420360148910080
author Nayak, Chandrakant
Acharyya, Biplab
Jain, Mantu
Kamboj, Kulbhushan
author_facet Nayak, Chandrakant
Acharyya, Biplab
Jain, Mantu
Kamboj, Kulbhushan
author_sort Nayak, Chandrakant
collection PubMed
description PURPOSE: Reduction and fixation in femoral neck fracture in young patients have a problem of nonunion, requiring additional procedures like valgus osteotomy; but fixation devices are technically difficult for inexperienced surgeons. We aims to assess the results of valgus osteotomy in femoral neck fracture in our setup. METHODS: We reported a series of 20 patients of higher Pauwel's angled fracture of femoral neck fracture presenting late wherein valgus osteotomy was added to reduction fixation which was secured with a commonly available 135° dynamic hip screw and plate. RESULTS: Femoral neck fractures united in 16 patients (80%). Excellent to good results (Harris hip score >80) were seen in 70% patients. Angle of correction of preoperative Pauwels has been changed from 68.3 to 34.3. CONCLUSION: The 135° dynamic hip screw and plate provides rigid internal fixation after valgus osteotomy and being a more familiar fixation device simplifies the procedure with good results.
format Online
Article
Text
id pubmed-6529366
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-65293662019-05-28 Valgus osteotomy in delayed presentation of femoral neck fractures using fixed angle simple dynamic hip screw and plate Nayak, Chandrakant Acharyya, Biplab Jain, Mantu Kamboj, Kulbhushan Chin J Traumatol Original article PURPOSE: Reduction and fixation in femoral neck fracture in young patients have a problem of nonunion, requiring additional procedures like valgus osteotomy; but fixation devices are technically difficult for inexperienced surgeons. We aims to assess the results of valgus osteotomy in femoral neck fracture in our setup. METHODS: We reported a series of 20 patients of higher Pauwel's angled fracture of femoral neck fracture presenting late wherein valgus osteotomy was added to reduction fixation which was secured with a commonly available 135° dynamic hip screw and plate. RESULTS: Femoral neck fractures united in 16 patients (80%). Excellent to good results (Harris hip score >80) were seen in 70% patients. Angle of correction of preoperative Pauwels has been changed from 68.3 to 34.3. CONCLUSION: The 135° dynamic hip screw and plate provides rigid internal fixation after valgus osteotomy and being a more familiar fixation device simplifies the procedure with good results. Elsevier 2019-02 2019-01-29 /pmc/articles/PMC6529366/ /pubmed/30824174 http://dx.doi.org/10.1016/j.cjtee.2018.12.003 Text en © 2019 Chinese Medical Association. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original article
Nayak, Chandrakant
Acharyya, Biplab
Jain, Mantu
Kamboj, Kulbhushan
Valgus osteotomy in delayed presentation of femoral neck fractures using fixed angle simple dynamic hip screw and plate
title Valgus osteotomy in delayed presentation of femoral neck fractures using fixed angle simple dynamic hip screw and plate
title_full Valgus osteotomy in delayed presentation of femoral neck fractures using fixed angle simple dynamic hip screw and plate
title_fullStr Valgus osteotomy in delayed presentation of femoral neck fractures using fixed angle simple dynamic hip screw and plate
title_full_unstemmed Valgus osteotomy in delayed presentation of femoral neck fractures using fixed angle simple dynamic hip screw and plate
title_short Valgus osteotomy in delayed presentation of femoral neck fractures using fixed angle simple dynamic hip screw and plate
title_sort valgus osteotomy in delayed presentation of femoral neck fractures using fixed angle simple dynamic hip screw and plate
topic Original article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6529366/
https://www.ncbi.nlm.nih.gov/pubmed/30824174
http://dx.doi.org/10.1016/j.cjtee.2018.12.003
work_keys_str_mv AT nayakchandrakant valgusosteotomyindelayedpresentationoffemoralneckfracturesusingfixedanglesimpledynamichipscrewandplate
AT acharyyabiplab valgusosteotomyindelayedpresentationoffemoralneckfracturesusingfixedanglesimpledynamichipscrewandplate
AT jainmantu valgusosteotomyindelayedpresentationoffemoralneckfracturesusingfixedanglesimpledynamichipscrewandplate
AT kambojkulbhushan valgusosteotomyindelayedpresentationoffemoralneckfracturesusingfixedanglesimpledynamichipscrewandplate