Cargando…

Transarterial embolization of a large high-flow right renal arteriovenous fistula using stents and an across-stent wire-trapping technique

Renal arteriovenous fistulas (AVFs) are rare vascular abnormalities. Their high-flow nature may result in increased cardiac output and lead to heart failure. Transcatheter endovascular management of renal AVFs with various embolization materials has been the treatment of choice in recent years. Embo...

Descripción completa

Detalles Bibliográficos
Autores principales: Shie, Ren-Fu, Su, Ta-Wei, Hsu, Ming-Yi, Chu, Sung-Yu, Ko, Po-Jen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6529687/
https://www.ncbi.nlm.nih.gov/pubmed/31193393
http://dx.doi.org/10.1016/j.jvscit.2018.12.003
_version_ 1783420453650432000
author Shie, Ren-Fu
Su, Ta-Wei
Hsu, Ming-Yi
Chu, Sung-Yu
Ko, Po-Jen
author_facet Shie, Ren-Fu
Su, Ta-Wei
Hsu, Ming-Yi
Chu, Sung-Yu
Ko, Po-Jen
author_sort Shie, Ren-Fu
collection PubMed
description Renal arteriovenous fistulas (AVFs) are rare vascular abnormalities. Their high-flow nature may result in increased cardiac output and lead to heart failure. Transcatheter endovascular management of renal AVFs with various embolization materials has been the treatment of choice in recent years. Embolization of large renal AVFs poses a risk of embolization through the AVF to the pulmonary circulation. Herein, we present the case of a patient whose large high-flow renal AVF was treated by a novel method involving the use of a bare stent and detachable metallic coils—called a wire-trapping technique—as well as compare this method with vascular plugs.
format Online
Article
Text
id pubmed-6529687
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-65296872019-05-28 Transarterial embolization of a large high-flow right renal arteriovenous fistula using stents and an across-stent wire-trapping technique Shie, Ren-Fu Su, Ta-Wei Hsu, Ming-Yi Chu, Sung-Yu Ko, Po-Jen J Vasc Surg Cases Innov Tech Arteriovenous fistula Renal arteriovenous fistulas (AVFs) are rare vascular abnormalities. Their high-flow nature may result in increased cardiac output and lead to heart failure. Transcatheter endovascular management of renal AVFs with various embolization materials has been the treatment of choice in recent years. Embolization of large renal AVFs poses a risk of embolization through the AVF to the pulmonary circulation. Herein, we present the case of a patient whose large high-flow renal AVF was treated by a novel method involving the use of a bare stent and detachable metallic coils—called a wire-trapping technique—as well as compare this method with vascular plugs. Elsevier 2019-04-28 /pmc/articles/PMC6529687/ /pubmed/31193393 http://dx.doi.org/10.1016/j.jvscit.2018.12.003 Text en © 2019 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Arteriovenous fistula
Shie, Ren-Fu
Su, Ta-Wei
Hsu, Ming-Yi
Chu, Sung-Yu
Ko, Po-Jen
Transarterial embolization of a large high-flow right renal arteriovenous fistula using stents and an across-stent wire-trapping technique
title Transarterial embolization of a large high-flow right renal arteriovenous fistula using stents and an across-stent wire-trapping technique
title_full Transarterial embolization of a large high-flow right renal arteriovenous fistula using stents and an across-stent wire-trapping technique
title_fullStr Transarterial embolization of a large high-flow right renal arteriovenous fistula using stents and an across-stent wire-trapping technique
title_full_unstemmed Transarterial embolization of a large high-flow right renal arteriovenous fistula using stents and an across-stent wire-trapping technique
title_short Transarterial embolization of a large high-flow right renal arteriovenous fistula using stents and an across-stent wire-trapping technique
title_sort transarterial embolization of a large high-flow right renal arteriovenous fistula using stents and an across-stent wire-trapping technique
topic Arteriovenous fistula
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6529687/
https://www.ncbi.nlm.nih.gov/pubmed/31193393
http://dx.doi.org/10.1016/j.jvscit.2018.12.003
work_keys_str_mv AT shierenfu transarterialembolizationofalargehighflowrightrenalarteriovenousfistulausingstentsandanacrossstentwiretrappingtechnique
AT sutawei transarterialembolizationofalargehighflowrightrenalarteriovenousfistulausingstentsandanacrossstentwiretrappingtechnique
AT hsumingyi transarterialembolizationofalargehighflowrightrenalarteriovenousfistulausingstentsandanacrossstentwiretrappingtechnique
AT chusungyu transarterialembolizationofalargehighflowrightrenalarteriovenousfistulausingstentsandanacrossstentwiretrappingtechnique
AT kopojen transarterialembolizationofalargehighflowrightrenalarteriovenousfistulausingstentsandanacrossstentwiretrappingtechnique