Implant insertion torque value in immediate loading: A retrospective study

BACKGROUND: The aim of this study is to verify if the Insertion Torque Value (ITV) of 32 Ncm for immediate loading protocol (ILP), as indicated by literature, is still, with the advance in implant research, a real significant cut-off for long-term implant survival. MATERIAL AND METHODS: In this retr...

Descripción completa

Detalles Bibliográficos
Autores principales: Del Giudice, Roberto, Piattelli, Adriano, Grande, Nicola-Maria, Cataneo, Enrico, Crispino, Antonio, Petrini, Morena
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medicina Oral S.L. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6530943/
https://www.ncbi.nlm.nih.gov/pubmed/31011142
http://dx.doi.org/10.4317/medoral.22845
_version_ 1783420723780386816
author Del Giudice, Roberto
Piattelli, Adriano
Grande, Nicola-Maria
Cataneo, Enrico
Crispino, Antonio
Petrini, Morena
author_facet Del Giudice, Roberto
Piattelli, Adriano
Grande, Nicola-Maria
Cataneo, Enrico
Crispino, Antonio
Petrini, Morena
author_sort Del Giudice, Roberto
collection PubMed
description BACKGROUND: The aim of this study is to verify if the Insertion Torque Value (ITV) of 32 Ncm for immediate loading protocol (ILP), as indicated by literature, is still, with the advance in implant research, a real significant cut-off for long-term implant survival. MATERIAL AND METHODS: In this retrospective study, data from 224 patients that during three years of clinical practice, were submitted to the insertion of 322 implants with immediate loading protocol, have been recorded, pooled and analyzed. Data were organized based on Insertion Torque Value (ITV): > 32 Ncm (CG) and < 32 Ncm (LTG) and two different groups of equal sample size, 161 implants each, were distinguished. Crestal bone reabsorption, and the implant failure rate were evaluated after 2-years of follow-up. RESULTS: The bone reabsorption in LTG (0.49 ± 0.11 mm) was significantly greater than CG (0.22 ± 0.04 mm), p<0.001. However, the survival rate after 2-years of follow-up was quite high and similar for both groups: 96.89% for LTG and 97.52% for CG and no statistically significant differences have been found among the two groups for the implant failure rate (p=0.455). The Odds Ratio (OR) of implant failure was of 1.258 (95% CI 0.332, 4.772), but results were not statistical significant, p=0.740. CONCLUSIONS: The present study showed that although implants with ITV> 32 Ncm are still characterized by a lower crestal bone resorption, there are no statistically significant differences among the two groups for what concerning the failure rate during the 2 years of follow-up and OR. These results permit us to suppose that the cut-off of ITV >32 Ncm for immediate loading implants, could be reduced to inferior values. However further studies are necessary to indicate precise clinical guidelines. Key words:Immediate loading, insertion torque, primary stability, dental implants, implant survival.
format Online
Article
Text
id pubmed-6530943
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Medicina Oral S.L.
record_format MEDLINE/PubMed
spelling pubmed-65309432019-05-28 Implant insertion torque value in immediate loading: A retrospective study Del Giudice, Roberto Piattelli, Adriano Grande, Nicola-Maria Cataneo, Enrico Crispino, Antonio Petrini, Morena Med Oral Patol Oral Cir Bucal Research BACKGROUND: The aim of this study is to verify if the Insertion Torque Value (ITV) of 32 Ncm for immediate loading protocol (ILP), as indicated by literature, is still, with the advance in implant research, a real significant cut-off for long-term implant survival. MATERIAL AND METHODS: In this retrospective study, data from 224 patients that during three years of clinical practice, were submitted to the insertion of 322 implants with immediate loading protocol, have been recorded, pooled and analyzed. Data were organized based on Insertion Torque Value (ITV): > 32 Ncm (CG) and < 32 Ncm (LTG) and two different groups of equal sample size, 161 implants each, were distinguished. Crestal bone reabsorption, and the implant failure rate were evaluated after 2-years of follow-up. RESULTS: The bone reabsorption in LTG (0.49 ± 0.11 mm) was significantly greater than CG (0.22 ± 0.04 mm), p<0.001. However, the survival rate after 2-years of follow-up was quite high and similar for both groups: 96.89% for LTG and 97.52% for CG and no statistically significant differences have been found among the two groups for the implant failure rate (p=0.455). The Odds Ratio (OR) of implant failure was of 1.258 (95% CI 0.332, 4.772), but results were not statistical significant, p=0.740. CONCLUSIONS: The present study showed that although implants with ITV> 32 Ncm are still characterized by a lower crestal bone resorption, there are no statistically significant differences among the two groups for what concerning the failure rate during the 2 years of follow-up and OR. These results permit us to suppose that the cut-off of ITV >32 Ncm for immediate loading implants, could be reduced to inferior values. However further studies are necessary to indicate precise clinical guidelines. Key words:Immediate loading, insertion torque, primary stability, dental implants, implant survival. Medicina Oral S.L. 2019-05 2019-04-24 /pmc/articles/PMC6530943/ /pubmed/31011142 http://dx.doi.org/10.4317/medoral.22845 Text en Copyright: © 2019 Medicina Oral S.L. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Del Giudice, Roberto
Piattelli, Adriano
Grande, Nicola-Maria
Cataneo, Enrico
Crispino, Antonio
Petrini, Morena
Implant insertion torque value in immediate loading: A retrospective study
title Implant insertion torque value in immediate loading: A retrospective study
title_full Implant insertion torque value in immediate loading: A retrospective study
title_fullStr Implant insertion torque value in immediate loading: A retrospective study
title_full_unstemmed Implant insertion torque value in immediate loading: A retrospective study
title_short Implant insertion torque value in immediate loading: A retrospective study
title_sort implant insertion torque value in immediate loading: a retrospective study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6530943/
https://www.ncbi.nlm.nih.gov/pubmed/31011142
http://dx.doi.org/10.4317/medoral.22845
work_keys_str_mv AT delgiudiceroberto implantinsertiontorquevalueinimmediateloadingaretrospectivestudy
AT piattelliadriano implantinsertiontorquevalueinimmediateloadingaretrospectivestudy
AT grandenicolamaria implantinsertiontorquevalueinimmediateloadingaretrospectivestudy
AT cataneoenrico implantinsertiontorquevalueinimmediateloadingaretrospectivestudy
AT crispinoantonio implantinsertiontorquevalueinimmediateloadingaretrospectivestudy
AT petrinimorena implantinsertiontorquevalueinimmediateloadingaretrospectivestudy