Real-Life Management and Effectiveness of Insulin Pump with or Without Continuous Glucose Monitoring in Adults with Type 1 Diabetes

INTRODUCTION: To describe and compare the routine use of continuous subcutaneous insulin infusion (CSII) in type 1 diabetes (T1D) patients with and without continuous glucose monitoring (CGM) in routine clinical practice and its relationship with glycemic outcomes. METHODS: Retrospective observation...

Descripción completa

Detalles Bibliográficos
Autores principales: Viñals, Clara, Quirós, Carmen, Giménez, Marga, Conget, Ignacio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Healthcare 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6531534/
https://www.ncbi.nlm.nih.gov/pubmed/30900146
http://dx.doi.org/10.1007/s13300-019-0599-1
_version_ 1783420854603874304
author Viñals, Clara
Quirós, Carmen
Giménez, Marga
Conget, Ignacio
author_facet Viñals, Clara
Quirós, Carmen
Giménez, Marga
Conget, Ignacio
author_sort Viñals, Clara
collection PubMed
description INTRODUCTION: To describe and compare the routine use of continuous subcutaneous insulin infusion (CSII) in type 1 diabetes (T1D) patients with and without continuous glucose monitoring (CGM) in routine clinical practice and its relationship with glycemic outcomes. METHODS: Retrospective observational case–control study collecting routine use of CSII and CGM in T1D patients between January 2016 and December 2016. Patients with T1D using sensor augmented pump (SAP) were matched by sex and disease duration in a 1:3 ratio with those treated only with CSII. Patients used a Paradigm Veo or 640G Medtronic-Minimed(®) insulin pump with or without a glucose sensor (Enlite, Medtronic-Minimed(®)) for at least 12 months. RESULTS: A total of 160 subjects with T1D were included, 40 using SAP and 120 on CSII (age 47 ± 12 years, 88 women, diabetes duration 29 ± 9.0 years, 10 ± 4.7 years on CSII, HbA(1C) 7.6 ± 0.8%). Those in SAP therapy used the sensor 63% of time, performed less self-monitored blood glucose (SMBG)/day (3.3 ± 1.9 vs. 4.5 ± 2.0; p < 0.01), more bolus/day (6.2 ± 3.6 vs. 4.8 ± 1.6; p < 0.05), more basal insulin segment/day (6.5 ± 2.1 vs. 5.9 ± 1.5; p < 0.05), and more suspension time of the pump (97 ± 93 vs. 9.6 ± 20 min/day; p < 0.0001). Regarding metabolic control, SAP therapy patients had lower HbA(1c) (7.4 ± 0.7 vs. 7.7 ± 0.9%; p = 0.068), lower average SMBG value (151 ± 32 vs. 163 ± 30 mg/dL; p < 0.05), a lower percentage of SMBG values greater than 180 mg/dL (30 ± 19 vs. 37 ± 16%; p < 0.05) with no differences in SMBG values less than 70 mg/dL (12 ± 8.0 vs. 9.8 ± 9.8%; p = 0.33) compared with patients on CSII. There were no differences in bolus wizard targets or in insulin/carbohydrate ratios per day. CONCLUSION: In a real-world setting, SAP therapy is associated with more self-adjustments of insulin therapy when compared to CSII alone. This could result in an improvement in glucose control.
format Online
Article
Text
id pubmed-6531534
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer Healthcare
record_format MEDLINE/PubMed
spelling pubmed-65315342019-06-07 Real-Life Management and Effectiveness of Insulin Pump with or Without Continuous Glucose Monitoring in Adults with Type 1 Diabetes Viñals, Clara Quirós, Carmen Giménez, Marga Conget, Ignacio Diabetes Ther Original Research INTRODUCTION: To describe and compare the routine use of continuous subcutaneous insulin infusion (CSII) in type 1 diabetes (T1D) patients with and without continuous glucose monitoring (CGM) in routine clinical practice and its relationship with glycemic outcomes. METHODS: Retrospective observational case–control study collecting routine use of CSII and CGM in T1D patients between January 2016 and December 2016. Patients with T1D using sensor augmented pump (SAP) were matched by sex and disease duration in a 1:3 ratio with those treated only with CSII. Patients used a Paradigm Veo or 640G Medtronic-Minimed(®) insulin pump with or without a glucose sensor (Enlite, Medtronic-Minimed(®)) for at least 12 months. RESULTS: A total of 160 subjects with T1D were included, 40 using SAP and 120 on CSII (age 47 ± 12 years, 88 women, diabetes duration 29 ± 9.0 years, 10 ± 4.7 years on CSII, HbA(1C) 7.6 ± 0.8%). Those in SAP therapy used the sensor 63% of time, performed less self-monitored blood glucose (SMBG)/day (3.3 ± 1.9 vs. 4.5 ± 2.0; p < 0.01), more bolus/day (6.2 ± 3.6 vs. 4.8 ± 1.6; p < 0.05), more basal insulin segment/day (6.5 ± 2.1 vs. 5.9 ± 1.5; p < 0.05), and more suspension time of the pump (97 ± 93 vs. 9.6 ± 20 min/day; p < 0.0001). Regarding metabolic control, SAP therapy patients had lower HbA(1c) (7.4 ± 0.7 vs. 7.7 ± 0.9%; p = 0.068), lower average SMBG value (151 ± 32 vs. 163 ± 30 mg/dL; p < 0.05), a lower percentage of SMBG values greater than 180 mg/dL (30 ± 19 vs. 37 ± 16%; p < 0.05) with no differences in SMBG values less than 70 mg/dL (12 ± 8.0 vs. 9.8 ± 9.8%; p = 0.33) compared with patients on CSII. There were no differences in bolus wizard targets or in insulin/carbohydrate ratios per day. CONCLUSION: In a real-world setting, SAP therapy is associated with more self-adjustments of insulin therapy when compared to CSII alone. This could result in an improvement in glucose control. Springer Healthcare 2019-03-21 2019-06 /pmc/articles/PMC6531534/ /pubmed/30900146 http://dx.doi.org/10.1007/s13300-019-0599-1 Text en © The Author(s) 2019 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ), which permits any noncommercial use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Research
Viñals, Clara
Quirós, Carmen
Giménez, Marga
Conget, Ignacio
Real-Life Management and Effectiveness of Insulin Pump with or Without Continuous Glucose Monitoring in Adults with Type 1 Diabetes
title Real-Life Management and Effectiveness of Insulin Pump with or Without Continuous Glucose Monitoring in Adults with Type 1 Diabetes
title_full Real-Life Management and Effectiveness of Insulin Pump with or Without Continuous Glucose Monitoring in Adults with Type 1 Diabetes
title_fullStr Real-Life Management and Effectiveness of Insulin Pump with or Without Continuous Glucose Monitoring in Adults with Type 1 Diabetes
title_full_unstemmed Real-Life Management and Effectiveness of Insulin Pump with or Without Continuous Glucose Monitoring in Adults with Type 1 Diabetes
title_short Real-Life Management and Effectiveness of Insulin Pump with or Without Continuous Glucose Monitoring in Adults with Type 1 Diabetes
title_sort real-life management and effectiveness of insulin pump with or without continuous glucose monitoring in adults with type 1 diabetes
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6531534/
https://www.ncbi.nlm.nih.gov/pubmed/30900146
http://dx.doi.org/10.1007/s13300-019-0599-1
work_keys_str_mv AT vinalsclara reallifemanagementandeffectivenessofinsulinpumpwithorwithoutcontinuousglucosemonitoringinadultswithtype1diabetes
AT quiroscarmen reallifemanagementandeffectivenessofinsulinpumpwithorwithoutcontinuousglucosemonitoringinadultswithtype1diabetes
AT gimenezmarga reallifemanagementandeffectivenessofinsulinpumpwithorwithoutcontinuousglucosemonitoringinadultswithtype1diabetes
AT congetignacio reallifemanagementandeffectivenessofinsulinpumpwithorwithoutcontinuousglucosemonitoringinadultswithtype1diabetes