Cargando…

Evaluation of semi-preloaded intraocular lens delivery system

Purpose: In this study, we aimed to evaluate the single surgeon experience of semi-preloaded intraocular lens (IOL) delivery system. Methods: Phacoemulsification was performed under topical anesthesia by temporal clear corneal incision. CT Lucia hydrophobic IOL was injected through semi- preloaded I...

Descripción completa

Detalles Bibliográficos
Autor principal: Rajesh, Rajesh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Romanian Society of Ophthalmology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6531765/
https://www.ncbi.nlm.nih.gov/pubmed/31198898
_version_ 1783420869833392128
author Rajesh, Rajesh
author_facet Rajesh, Rajesh
author_sort Rajesh, Rajesh
collection PubMed
description Purpose: In this study, we aimed to evaluate the single surgeon experience of semi-preloaded intraocular lens (IOL) delivery system. Methods: Phacoemulsification was performed under topical anesthesia by temporal clear corneal incision. CT Lucia hydrophobic IOL was injected through semi- preloaded IOL system in the capsular bag. Two hundred patients (200 eyes) were included in the study. The main outcome measures were ease of implantation, intraoperative and postoperative complications, postoperative centration, and visual acuity. Data on successful implantation and complications were collected prospectively. Results: Correct IOL delivery was achieved in 193 out of 200 patients (96.5%). Four patients (2%) required intrawound rotation of the injector to place the leading haptic in the capsular bag. Two patients (1%) had anteroposterior rotation of the IOL and one patient (0.5%) had total posterior rotation of IOL. Other problems noted were trapped trailing haptic (n=2,1%), improper loading of IOL (n=3,1.5%) and stretch marks on the optic of IOL (n=4,2%). None of the patients had iris trauma or posterior capsular rupture during the implantation and manipulation of the IOL. The mean incision size after completion of implantation of IOL was 2.82 mm (+ 0.02), which achieved sutureless closure. None of the patients developed postoperative infection. Conclusion: Implantation of CT Lucia 601 PY IOL with the semi preloaded system led to minor complications and gave satisfactory visual results.
format Online
Article
Text
id pubmed-6531765
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Romanian Society of Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-65317652019-06-13 Evaluation of semi-preloaded intraocular lens delivery system Rajesh, Rajesh Rom J Ophthalmol General Articles Purpose: In this study, we aimed to evaluate the single surgeon experience of semi-preloaded intraocular lens (IOL) delivery system. Methods: Phacoemulsification was performed under topical anesthesia by temporal clear corneal incision. CT Lucia hydrophobic IOL was injected through semi- preloaded IOL system in the capsular bag. Two hundred patients (200 eyes) were included in the study. The main outcome measures were ease of implantation, intraoperative and postoperative complications, postoperative centration, and visual acuity. Data on successful implantation and complications were collected prospectively. Results: Correct IOL delivery was achieved in 193 out of 200 patients (96.5%). Four patients (2%) required intrawound rotation of the injector to place the leading haptic in the capsular bag. Two patients (1%) had anteroposterior rotation of the IOL and one patient (0.5%) had total posterior rotation of IOL. Other problems noted were trapped trailing haptic (n=2,1%), improper loading of IOL (n=3,1.5%) and stretch marks on the optic of IOL (n=4,2%). None of the patients had iris trauma or posterior capsular rupture during the implantation and manipulation of the IOL. The mean incision size after completion of implantation of IOL was 2.82 mm (+ 0.02), which achieved sutureless closure. None of the patients developed postoperative infection. Conclusion: Implantation of CT Lucia 601 PY IOL with the semi preloaded system led to minor complications and gave satisfactory visual results. Romanian Society of Ophthalmology 2019 /pmc/articles/PMC6531765/ /pubmed/31198898 Text en ©Romanian Society of Ophthalmology http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle General Articles
Rajesh, Rajesh
Evaluation of semi-preloaded intraocular lens delivery system
title Evaluation of semi-preloaded intraocular lens delivery system
title_full Evaluation of semi-preloaded intraocular lens delivery system
title_fullStr Evaluation of semi-preloaded intraocular lens delivery system
title_full_unstemmed Evaluation of semi-preloaded intraocular lens delivery system
title_short Evaluation of semi-preloaded intraocular lens delivery system
title_sort evaluation of semi-preloaded intraocular lens delivery system
topic General Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6531765/
https://www.ncbi.nlm.nih.gov/pubmed/31198898
work_keys_str_mv AT rajeshrajesh evaluationofsemipreloadedintraocularlensdeliverysystem