Cargando…

The effect of coronal prosthetic alignment changes on socket reaction moments, spatiotemporal parameters, and perception of alignment during gait in individuals with transtibial amputation

INTRODUCTION: The alignment of a prosthesis is clinically determined based on observations by clinicians and the subjective perception of amputees during gait. However, this process has been reported to be unreliable. Socket reaction moment has been reported to be significantly impacted by alignment...

Descripción completa

Detalles Bibliográficos
Autores principales: Hashimoto, Hiroshi, Kobayashi, Toshiki, Gao, Fan, Kataoka, Masataka, Okuda, Kuniharu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6531796/
https://www.ncbi.nlm.nih.gov/pubmed/31191953
http://dx.doi.org/10.1177/2055668318795402
_version_ 1783420877383139328
author Hashimoto, Hiroshi
Kobayashi, Toshiki
Gao, Fan
Kataoka, Masataka
Okuda, Kuniharu
author_facet Hashimoto, Hiroshi
Kobayashi, Toshiki
Gao, Fan
Kataoka, Masataka
Okuda, Kuniharu
author_sort Hashimoto, Hiroshi
collection PubMed
description INTRODUCTION: The alignment of a prosthesis is clinically determined based on observations by clinicians and the subjective perception of amputees during gait. However, this process has been reported to be unreliable. Socket reaction moment has been reported to be significantly impacted by alignment changes, but the impact of these alignment changes on other gait parameters is unclear. The aim of this study was to investigate the effects of coronal alignment changes of a transtibial prosthesis on socket reaction moment, spatiotemporal parameters, and perceptions of alignment during gait in amputees. METHODS: Nine individuals with transtibial amputation participated in this study. Socket reaction moment and spatiotemporal parameters (step time, step length, step width, single limb support time, cadence, and gait speed) were measured under nine coronal alignment conditions (angulation: ±3°, ±6°, translation: ±5 mm, ±10 mm, and baseline) using a three-dimensional motion capture system (Vicon) and an embedded load-cell system (Europa™). In addition, subjective perceptions of alignment were examined. RESULTS: Coronal alignment changes of the transtibial prostheses demonstrated significant changes in socket reaction moment; however, no significant changes were found with spatiotemporal parameters or the amputee’s perception. CONCLUSION: Measurement of socket reaction moment, along with the embedded load-cell system, may be a better metric for tuning the coronal alignment of transtibial prostheses compared to spatiotemporal parameters and amputee’s perceptions.
format Online
Article
Text
id pubmed-6531796
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-65317962019-06-12 The effect of coronal prosthetic alignment changes on socket reaction moments, spatiotemporal parameters, and perception of alignment during gait in individuals with transtibial amputation Hashimoto, Hiroshi Kobayashi, Toshiki Gao, Fan Kataoka, Masataka Okuda, Kuniharu J Rehabil Assist Technol Eng Smart Limb Technology: Orignial Research Article INTRODUCTION: The alignment of a prosthesis is clinically determined based on observations by clinicians and the subjective perception of amputees during gait. However, this process has been reported to be unreliable. Socket reaction moment has been reported to be significantly impacted by alignment changes, but the impact of these alignment changes on other gait parameters is unclear. The aim of this study was to investigate the effects of coronal alignment changes of a transtibial prosthesis on socket reaction moment, spatiotemporal parameters, and perceptions of alignment during gait in amputees. METHODS: Nine individuals with transtibial amputation participated in this study. Socket reaction moment and spatiotemporal parameters (step time, step length, step width, single limb support time, cadence, and gait speed) were measured under nine coronal alignment conditions (angulation: ±3°, ±6°, translation: ±5 mm, ±10 mm, and baseline) using a three-dimensional motion capture system (Vicon) and an embedded load-cell system (Europa™). In addition, subjective perceptions of alignment were examined. RESULTS: Coronal alignment changes of the transtibial prostheses demonstrated significant changes in socket reaction moment; however, no significant changes were found with spatiotemporal parameters or the amputee’s perception. CONCLUSION: Measurement of socket reaction moment, along with the embedded load-cell system, may be a better metric for tuning the coronal alignment of transtibial prostheses compared to spatiotemporal parameters and amputee’s perceptions. SAGE Publications 2018-11-18 /pmc/articles/PMC6531796/ /pubmed/31191953 http://dx.doi.org/10.1177/2055668318795402 Text en © The Author(s) 2018 http://creativecommons.org/licenses/by-nc/4.0/ Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Smart Limb Technology: Orignial Research Article
Hashimoto, Hiroshi
Kobayashi, Toshiki
Gao, Fan
Kataoka, Masataka
Okuda, Kuniharu
The effect of coronal prosthetic alignment changes on socket reaction moments, spatiotemporal parameters, and perception of alignment during gait in individuals with transtibial amputation
title The effect of coronal prosthetic alignment changes on socket reaction moments, spatiotemporal parameters, and perception of alignment during gait in individuals with transtibial amputation
title_full The effect of coronal prosthetic alignment changes on socket reaction moments, spatiotemporal parameters, and perception of alignment during gait in individuals with transtibial amputation
title_fullStr The effect of coronal prosthetic alignment changes on socket reaction moments, spatiotemporal parameters, and perception of alignment during gait in individuals with transtibial amputation
title_full_unstemmed The effect of coronal prosthetic alignment changes on socket reaction moments, spatiotemporal parameters, and perception of alignment during gait in individuals with transtibial amputation
title_short The effect of coronal prosthetic alignment changes on socket reaction moments, spatiotemporal parameters, and perception of alignment during gait in individuals with transtibial amputation
title_sort effect of coronal prosthetic alignment changes on socket reaction moments, spatiotemporal parameters, and perception of alignment during gait in individuals with transtibial amputation
topic Smart Limb Technology: Orignial Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6531796/
https://www.ncbi.nlm.nih.gov/pubmed/31191953
http://dx.doi.org/10.1177/2055668318795402
work_keys_str_mv AT hashimotohiroshi theeffectofcoronalprostheticalignmentchangesonsocketreactionmomentsspatiotemporalparametersandperceptionofalignmentduringgaitinindividualswithtranstibialamputation
AT kobayashitoshiki theeffectofcoronalprostheticalignmentchangesonsocketreactionmomentsspatiotemporalparametersandperceptionofalignmentduringgaitinindividualswithtranstibialamputation
AT gaofan theeffectofcoronalprostheticalignmentchangesonsocketreactionmomentsspatiotemporalparametersandperceptionofalignmentduringgaitinindividualswithtranstibialamputation
AT kataokamasataka theeffectofcoronalprostheticalignmentchangesonsocketreactionmomentsspatiotemporalparametersandperceptionofalignmentduringgaitinindividualswithtranstibialamputation
AT okudakuniharu theeffectofcoronalprostheticalignmentchangesonsocketreactionmomentsspatiotemporalparametersandperceptionofalignmentduringgaitinindividualswithtranstibialamputation
AT hashimotohiroshi effectofcoronalprostheticalignmentchangesonsocketreactionmomentsspatiotemporalparametersandperceptionofalignmentduringgaitinindividualswithtranstibialamputation
AT kobayashitoshiki effectofcoronalprostheticalignmentchangesonsocketreactionmomentsspatiotemporalparametersandperceptionofalignmentduringgaitinindividualswithtranstibialamputation
AT gaofan effectofcoronalprostheticalignmentchangesonsocketreactionmomentsspatiotemporalparametersandperceptionofalignmentduringgaitinindividualswithtranstibialamputation
AT kataokamasataka effectofcoronalprostheticalignmentchangesonsocketreactionmomentsspatiotemporalparametersandperceptionofalignmentduringgaitinindividualswithtranstibialamputation
AT okudakuniharu effectofcoronalprostheticalignmentchangesonsocketreactionmomentsspatiotemporalparametersandperceptionofalignmentduringgaitinindividualswithtranstibialamputation