Cargando…

The Zurich Checklist for Safety in the Intraoperative Magnetic Resonance Imaging Suite: Technical Note

BACKGROUND: Recently, the use of intraoperative magnetic resonance imaging (ioMRI) has evolved in neurosurgery. Challenges related to ioMRI-augmented procedures are significant, since the magnetic field creates a potentially hazardous environment. Strict safety guidelines in the operating room (OR)...

Descripción completa

Detalles Bibliográficos
Autores principales: Stienen, Martin N, Fierstra, Jorn, Pangalu, Athina, Regli, Luca, Bozinov, Oliver
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6531895/
https://www.ncbi.nlm.nih.gov/pubmed/30099512
http://dx.doi.org/10.1093/ons/opy205
_version_ 1783420900662575104
author Stienen, Martin N
Fierstra, Jorn
Pangalu, Athina
Regli, Luca
Bozinov, Oliver
author_facet Stienen, Martin N
Fierstra, Jorn
Pangalu, Athina
Regli, Luca
Bozinov, Oliver
author_sort Stienen, Martin N
collection PubMed
description BACKGROUND: Recently, the use of intraoperative magnetic resonance imaging (ioMRI) has evolved in neurosurgery. Challenges related to ioMRI-augmented procedures are significant, since the magnetic field creates a potentially hazardous environment. Strict safety guidelines in the operating room (OR) are necessary. Checklists can minimize errors while increasing efficiency and improving workflow. OBJECTIVE: To describe the Zurich checklists for safety in the ioMRI environment. METHODS: We summarize the checklist protocol and the experience gained from over 300 surgical procedures performed over a 4-yr period using this new system for transcranial or transsphenoidal surgery in a 2-room high-field 3 Tesla ioMRI suite. RESULTS: Particularities of the 2-room setting used at our institution can be summarized as (1) patient transfer from a sterile to a nonsterile environment and (2) patient transfer from a zone without to a zone with a high-strength magnetic field. Steps on the checklist have been introduced for reasons of efficient workflow, safety pertaining to the strength of the magnetic field, or sterility concerns. Each step in the checklist corresponds to a specific phase and particular actions taken during the workflow in the ioMRI suite. Most steps are relevant to any 2-room ioMRI-OR suite. CONCLUSION: The use of an ioMRI-checklist promotes a zero-tolerance attitude for errors, can lower complications, and can help create an environment that is both efficient and safe for the patient and the OR personnel. We highly recommend the use of a surgical checklist when applying ioMRI.
format Online
Article
Text
id pubmed-6531895
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-65318952019-05-28 The Zurich Checklist for Safety in the Intraoperative Magnetic Resonance Imaging Suite: Technical Note Stienen, Martin N Fierstra, Jorn Pangalu, Athina Regli, Luca Bozinov, Oliver Oper Neurosurg (Hagerstown) Concepts, Innovations and Techniques BACKGROUND: Recently, the use of intraoperative magnetic resonance imaging (ioMRI) has evolved in neurosurgery. Challenges related to ioMRI-augmented procedures are significant, since the magnetic field creates a potentially hazardous environment. Strict safety guidelines in the operating room (OR) are necessary. Checklists can minimize errors while increasing efficiency and improving workflow. OBJECTIVE: To describe the Zurich checklists for safety in the ioMRI environment. METHODS: We summarize the checklist protocol and the experience gained from over 300 surgical procedures performed over a 4-yr period using this new system for transcranial or transsphenoidal surgery in a 2-room high-field 3 Tesla ioMRI suite. RESULTS: Particularities of the 2-room setting used at our institution can be summarized as (1) patient transfer from a sterile to a nonsterile environment and (2) patient transfer from a zone without to a zone with a high-strength magnetic field. Steps on the checklist have been introduced for reasons of efficient workflow, safety pertaining to the strength of the magnetic field, or sterility concerns. Each step in the checklist corresponds to a specific phase and particular actions taken during the workflow in the ioMRI suite. Most steps are relevant to any 2-room ioMRI-OR suite. CONCLUSION: The use of an ioMRI-checklist promotes a zero-tolerance attitude for errors, can lower complications, and can help create an environment that is both efficient and safe for the patient and the OR personnel. We highly recommend the use of a surgical checklist when applying ioMRI. Oxford University Press 2019-06 2018-08-07 /pmc/articles/PMC6531895/ /pubmed/30099512 http://dx.doi.org/10.1093/ons/opy205 Text en © Congress of Neurological Surgeons 2018. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (http://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Concepts, Innovations and Techniques
Stienen, Martin N
Fierstra, Jorn
Pangalu, Athina
Regli, Luca
Bozinov, Oliver
The Zurich Checklist for Safety in the Intraoperative Magnetic Resonance Imaging Suite: Technical Note
title The Zurich Checklist for Safety in the Intraoperative Magnetic Resonance Imaging Suite: Technical Note
title_full The Zurich Checklist for Safety in the Intraoperative Magnetic Resonance Imaging Suite: Technical Note
title_fullStr The Zurich Checklist for Safety in the Intraoperative Magnetic Resonance Imaging Suite: Technical Note
title_full_unstemmed The Zurich Checklist for Safety in the Intraoperative Magnetic Resonance Imaging Suite: Technical Note
title_short The Zurich Checklist for Safety in the Intraoperative Magnetic Resonance Imaging Suite: Technical Note
title_sort zurich checklist for safety in the intraoperative magnetic resonance imaging suite: technical note
topic Concepts, Innovations and Techniques
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6531895/
https://www.ncbi.nlm.nih.gov/pubmed/30099512
http://dx.doi.org/10.1093/ons/opy205
work_keys_str_mv AT stienenmartinn thezurichchecklistforsafetyintheintraoperativemagneticresonanceimagingsuitetechnicalnote
AT fierstrajorn thezurichchecklistforsafetyintheintraoperativemagneticresonanceimagingsuitetechnicalnote
AT pangaluathina thezurichchecklistforsafetyintheintraoperativemagneticresonanceimagingsuitetechnicalnote
AT regliluca thezurichchecklistforsafetyintheintraoperativemagneticresonanceimagingsuitetechnicalnote
AT bozinovoliver thezurichchecklistforsafetyintheintraoperativemagneticresonanceimagingsuitetechnicalnote
AT stienenmartinn zurichchecklistforsafetyintheintraoperativemagneticresonanceimagingsuitetechnicalnote
AT fierstrajorn zurichchecklistforsafetyintheintraoperativemagneticresonanceimagingsuitetechnicalnote
AT pangaluathina zurichchecklistforsafetyintheintraoperativemagneticresonanceimagingsuitetechnicalnote
AT regliluca zurichchecklistforsafetyintheintraoperativemagneticresonanceimagingsuitetechnicalnote
AT bozinovoliver zurichchecklistforsafetyintheintraoperativemagneticresonanceimagingsuitetechnicalnote