Cargando…
The Zurich Checklist for Safety in the Intraoperative Magnetic Resonance Imaging Suite: Technical Note
BACKGROUND: Recently, the use of intraoperative magnetic resonance imaging (ioMRI) has evolved in neurosurgery. Challenges related to ioMRI-augmented procedures are significant, since the magnetic field creates a potentially hazardous environment. Strict safety guidelines in the operating room (OR)...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6531895/ https://www.ncbi.nlm.nih.gov/pubmed/30099512 http://dx.doi.org/10.1093/ons/opy205 |
_version_ | 1783420900662575104 |
---|---|
author | Stienen, Martin N Fierstra, Jorn Pangalu, Athina Regli, Luca Bozinov, Oliver |
author_facet | Stienen, Martin N Fierstra, Jorn Pangalu, Athina Regli, Luca Bozinov, Oliver |
author_sort | Stienen, Martin N |
collection | PubMed |
description | BACKGROUND: Recently, the use of intraoperative magnetic resonance imaging (ioMRI) has evolved in neurosurgery. Challenges related to ioMRI-augmented procedures are significant, since the magnetic field creates a potentially hazardous environment. Strict safety guidelines in the operating room (OR) are necessary. Checklists can minimize errors while increasing efficiency and improving workflow. OBJECTIVE: To describe the Zurich checklists for safety in the ioMRI environment. METHODS: We summarize the checklist protocol and the experience gained from over 300 surgical procedures performed over a 4-yr period using this new system for transcranial or transsphenoidal surgery in a 2-room high-field 3 Tesla ioMRI suite. RESULTS: Particularities of the 2-room setting used at our institution can be summarized as (1) patient transfer from a sterile to a nonsterile environment and (2) patient transfer from a zone without to a zone with a high-strength magnetic field. Steps on the checklist have been introduced for reasons of efficient workflow, safety pertaining to the strength of the magnetic field, or sterility concerns. Each step in the checklist corresponds to a specific phase and particular actions taken during the workflow in the ioMRI suite. Most steps are relevant to any 2-room ioMRI-OR suite. CONCLUSION: The use of an ioMRI-checklist promotes a zero-tolerance attitude for errors, can lower complications, and can help create an environment that is both efficient and safe for the patient and the OR personnel. We highly recommend the use of a surgical checklist when applying ioMRI. |
format | Online Article Text |
id | pubmed-6531895 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-65318952019-05-28 The Zurich Checklist for Safety in the Intraoperative Magnetic Resonance Imaging Suite: Technical Note Stienen, Martin N Fierstra, Jorn Pangalu, Athina Regli, Luca Bozinov, Oliver Oper Neurosurg (Hagerstown) Concepts, Innovations and Techniques BACKGROUND: Recently, the use of intraoperative magnetic resonance imaging (ioMRI) has evolved in neurosurgery. Challenges related to ioMRI-augmented procedures are significant, since the magnetic field creates a potentially hazardous environment. Strict safety guidelines in the operating room (OR) are necessary. Checklists can minimize errors while increasing efficiency and improving workflow. OBJECTIVE: To describe the Zurich checklists for safety in the ioMRI environment. METHODS: We summarize the checklist protocol and the experience gained from over 300 surgical procedures performed over a 4-yr period using this new system for transcranial or transsphenoidal surgery in a 2-room high-field 3 Tesla ioMRI suite. RESULTS: Particularities of the 2-room setting used at our institution can be summarized as (1) patient transfer from a sterile to a nonsterile environment and (2) patient transfer from a zone without to a zone with a high-strength magnetic field. Steps on the checklist have been introduced for reasons of efficient workflow, safety pertaining to the strength of the magnetic field, or sterility concerns. Each step in the checklist corresponds to a specific phase and particular actions taken during the workflow in the ioMRI suite. Most steps are relevant to any 2-room ioMRI-OR suite. CONCLUSION: The use of an ioMRI-checklist promotes a zero-tolerance attitude for errors, can lower complications, and can help create an environment that is both efficient and safe for the patient and the OR personnel. We highly recommend the use of a surgical checklist when applying ioMRI. Oxford University Press 2019-06 2018-08-07 /pmc/articles/PMC6531895/ /pubmed/30099512 http://dx.doi.org/10.1093/ons/opy205 Text en © Congress of Neurological Surgeons 2018. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (http://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Concepts, Innovations and Techniques Stienen, Martin N Fierstra, Jorn Pangalu, Athina Regli, Luca Bozinov, Oliver The Zurich Checklist for Safety in the Intraoperative Magnetic Resonance Imaging Suite: Technical Note |
title | The Zurich Checklist for Safety in the Intraoperative Magnetic Resonance Imaging Suite: Technical Note |
title_full | The Zurich Checklist for Safety in the Intraoperative Magnetic Resonance Imaging Suite: Technical Note |
title_fullStr | The Zurich Checklist for Safety in the Intraoperative Magnetic Resonance Imaging Suite: Technical Note |
title_full_unstemmed | The Zurich Checklist for Safety in the Intraoperative Magnetic Resonance Imaging Suite: Technical Note |
title_short | The Zurich Checklist for Safety in the Intraoperative Magnetic Resonance Imaging Suite: Technical Note |
title_sort | zurich checklist for safety in the intraoperative magnetic resonance imaging suite: technical note |
topic | Concepts, Innovations and Techniques |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6531895/ https://www.ncbi.nlm.nih.gov/pubmed/30099512 http://dx.doi.org/10.1093/ons/opy205 |
work_keys_str_mv | AT stienenmartinn thezurichchecklistforsafetyintheintraoperativemagneticresonanceimagingsuitetechnicalnote AT fierstrajorn thezurichchecklistforsafetyintheintraoperativemagneticresonanceimagingsuitetechnicalnote AT pangaluathina thezurichchecklistforsafetyintheintraoperativemagneticresonanceimagingsuitetechnicalnote AT regliluca thezurichchecklistforsafetyintheintraoperativemagneticresonanceimagingsuitetechnicalnote AT bozinovoliver thezurichchecklistforsafetyintheintraoperativemagneticresonanceimagingsuitetechnicalnote AT stienenmartinn zurichchecklistforsafetyintheintraoperativemagneticresonanceimagingsuitetechnicalnote AT fierstrajorn zurichchecklistforsafetyintheintraoperativemagneticresonanceimagingsuitetechnicalnote AT pangaluathina zurichchecklistforsafetyintheintraoperativemagneticresonanceimagingsuitetechnicalnote AT regliluca zurichchecklistforsafetyintheintraoperativemagneticresonanceimagingsuitetechnicalnote AT bozinovoliver zurichchecklistforsafetyintheintraoperativemagneticresonanceimagingsuitetechnicalnote |