Cargando…
Comparative Analysis of Phase Lag Entropy and Bispectral Index as Anesthetic Depth Indicators in Patients Undergoing Thyroid Surgery with Nerve Integrity Monitoring
BACKGROUND: Most depth of anesthesia (DOA) monitors rely on the temporal characteristics of a single-channel electroencephalogram (EEG) and cannot provide spatial or connectivity information. Phase lag entropy (PLE) reflects DOA by calculating diverse connectivity from temporal patterns of phase rel...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Medical Sciences
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6535403/ https://www.ncbi.nlm.nih.gov/pubmed/31124327 http://dx.doi.org/10.3346/jkms.2019.34.e151 |
_version_ | 1783421562810007552 |
---|---|
author | Seo, Kwon Hui Kim, Kyung Mi Lee, Soo Kyung John, Hyunji Lee, Junsuck |
author_facet | Seo, Kwon Hui Kim, Kyung Mi Lee, Soo Kyung John, Hyunji Lee, Junsuck |
author_sort | Seo, Kwon Hui |
collection | PubMed |
description | BACKGROUND: Most depth of anesthesia (DOA) monitors rely on the temporal characteristics of a single-channel electroencephalogram (EEG) and cannot provide spatial or connectivity information. Phase lag entropy (PLE) reflects DOA by calculating diverse connectivity from temporal patterns of phase relationships. The aim of this study was to compare the performance of PLE and bispectral index (BIS) monitors for assessing DOA during anesthesia induction, nerve integrity monitoring (NIM), and anesthesia emergence. METHODS: Thirty-five patients undergoing elective thyroid surgery with recurrent laryngeal nerve NIM received propofol and remifentanil via target-controlled infusion. After applying PLE and BIS monitors, propofol infusion was initiated at a calculated effect site concentration (Ce) of 2 µg/mL and then increased in 1-µg/mL Ce increments. After propofol Ce reached 5 μg/mL, a remifentanil infusion was begun, and anesthesia induction was considered complete. During NIM, PLE and BIS values were compared at a specific time points from platysma muscle exposure to subcutaneous tissue closure. PLE and BIS values were recorded continuously from preanesthetic state to full recovery of orientation; bias and limits of agreement between monitors were calculated. RESULTS: PLE and BIS values decreased progressively with increasing propofol Ce during anesthetic induction and increased by stages during emergence. The prediction probabilities of PLE and BIS for detecting propofol Ce changes were 0.750 and 0.756, respectively, during induction and 0.749 and 0.746, respectively, during emergence. No aberrant PLE or BIS values occurred during NIM. Correlation coefficients for BIS and PLE were 0.98 and 0.92 during induction and emergence, respectively. PLE values were significantly higher than BIS values at full recovery of orientation. Estimated bias between monitors was −4.16 ± 8.7, and 95% limits of agreement were −21.21 to 12.89. CONCLUSION: PLE is a reasonable alternative to BIS for evaluating consciousness and DOA during general anesthesia and during NIM. TRIAL REGISTRATION: Clinical Research Information Service Identifier: KCT0003490 |
format | Online Article Text |
id | pubmed-6535403 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | The Korean Academy of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-65354032019-05-28 Comparative Analysis of Phase Lag Entropy and Bispectral Index as Anesthetic Depth Indicators in Patients Undergoing Thyroid Surgery with Nerve Integrity Monitoring Seo, Kwon Hui Kim, Kyung Mi Lee, Soo Kyung John, Hyunji Lee, Junsuck J Korean Med Sci Original Article BACKGROUND: Most depth of anesthesia (DOA) monitors rely on the temporal characteristics of a single-channel electroencephalogram (EEG) and cannot provide spatial or connectivity information. Phase lag entropy (PLE) reflects DOA by calculating diverse connectivity from temporal patterns of phase relationships. The aim of this study was to compare the performance of PLE and bispectral index (BIS) monitors for assessing DOA during anesthesia induction, nerve integrity monitoring (NIM), and anesthesia emergence. METHODS: Thirty-five patients undergoing elective thyroid surgery with recurrent laryngeal nerve NIM received propofol and remifentanil via target-controlled infusion. After applying PLE and BIS monitors, propofol infusion was initiated at a calculated effect site concentration (Ce) of 2 µg/mL and then increased in 1-µg/mL Ce increments. After propofol Ce reached 5 μg/mL, a remifentanil infusion was begun, and anesthesia induction was considered complete. During NIM, PLE and BIS values were compared at a specific time points from platysma muscle exposure to subcutaneous tissue closure. PLE and BIS values were recorded continuously from preanesthetic state to full recovery of orientation; bias and limits of agreement between monitors were calculated. RESULTS: PLE and BIS values decreased progressively with increasing propofol Ce during anesthetic induction and increased by stages during emergence. The prediction probabilities of PLE and BIS for detecting propofol Ce changes were 0.750 and 0.756, respectively, during induction and 0.749 and 0.746, respectively, during emergence. No aberrant PLE or BIS values occurred during NIM. Correlation coefficients for BIS and PLE were 0.98 and 0.92 during induction and emergence, respectively. PLE values were significantly higher than BIS values at full recovery of orientation. Estimated bias between monitors was −4.16 ± 8.7, and 95% limits of agreement were −21.21 to 12.89. CONCLUSION: PLE is a reasonable alternative to BIS for evaluating consciousness and DOA during general anesthesia and during NIM. TRIAL REGISTRATION: Clinical Research Information Service Identifier: KCT0003490 The Korean Academy of Medical Sciences 2019-05-15 /pmc/articles/PMC6535403/ /pubmed/31124327 http://dx.doi.org/10.3346/jkms.2019.34.e151 Text en © 2019 The Korean Academy of Medical Sciences. https://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Seo, Kwon Hui Kim, Kyung Mi Lee, Soo Kyung John, Hyunji Lee, Junsuck Comparative Analysis of Phase Lag Entropy and Bispectral Index as Anesthetic Depth Indicators in Patients Undergoing Thyroid Surgery with Nerve Integrity Monitoring |
title | Comparative Analysis of Phase Lag Entropy and Bispectral Index as Anesthetic Depth Indicators in Patients Undergoing Thyroid Surgery with Nerve Integrity Monitoring |
title_full | Comparative Analysis of Phase Lag Entropy and Bispectral Index as Anesthetic Depth Indicators in Patients Undergoing Thyroid Surgery with Nerve Integrity Monitoring |
title_fullStr | Comparative Analysis of Phase Lag Entropy and Bispectral Index as Anesthetic Depth Indicators in Patients Undergoing Thyroid Surgery with Nerve Integrity Monitoring |
title_full_unstemmed | Comparative Analysis of Phase Lag Entropy and Bispectral Index as Anesthetic Depth Indicators in Patients Undergoing Thyroid Surgery with Nerve Integrity Monitoring |
title_short | Comparative Analysis of Phase Lag Entropy and Bispectral Index as Anesthetic Depth Indicators in Patients Undergoing Thyroid Surgery with Nerve Integrity Monitoring |
title_sort | comparative analysis of phase lag entropy and bispectral index as anesthetic depth indicators in patients undergoing thyroid surgery with nerve integrity monitoring |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6535403/ https://www.ncbi.nlm.nih.gov/pubmed/31124327 http://dx.doi.org/10.3346/jkms.2019.34.e151 |
work_keys_str_mv | AT seokwonhui comparativeanalysisofphaselagentropyandbispectralindexasanestheticdepthindicatorsinpatientsundergoingthyroidsurgerywithnerveintegritymonitoring AT kimkyungmi comparativeanalysisofphaselagentropyandbispectralindexasanestheticdepthindicatorsinpatientsundergoingthyroidsurgerywithnerveintegritymonitoring AT leesookyung comparativeanalysisofphaselagentropyandbispectralindexasanestheticdepthindicatorsinpatientsundergoingthyroidsurgerywithnerveintegritymonitoring AT johnhyunji comparativeanalysisofphaselagentropyandbispectralindexasanestheticdepthindicatorsinpatientsundergoingthyroidsurgerywithnerveintegritymonitoring AT leejunsuck comparativeanalysisofphaselagentropyandbispectralindexasanestheticdepthindicatorsinpatientsundergoingthyroidsurgerywithnerveintegritymonitoring |