Cargando…

Experimental investigation on convective heat transfer and pressure drop of cone helically coiled tube heat exchanger using carbon nanotubes/water nanofluids

This study investigates the heat transfer and the pressure drop of cone helically coiled tube heat exchanger using (Multi wall carbon nano tube) MWCNT/water nanofluids. The MWCNT/water nanofluids at 0.1%, 0.3%, and 0.5% particle volume concentrations were prepared with the addition of surfactant by...

Descripción completa

Detalles Bibliográficos
Autores principales: Palanisamy, K., Mukesh Kumar, P.C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6536441/
https://www.ncbi.nlm.nih.gov/pubmed/31193520
http://dx.doi.org/10.1016/j.heliyon.2019.e01705
_version_ 1783421742154252288
author Palanisamy, K.
Mukesh Kumar, P.C.
author_facet Palanisamy, K.
Mukesh Kumar, P.C.
author_sort Palanisamy, K.
collection PubMed
description This study investigates the heat transfer and the pressure drop of cone helically coiled tube heat exchanger using (Multi wall carbon nano tube) MWCNT/water nanofluids. The MWCNT/water nanofluids at 0.1%, 0.3%, and 0.5% particle volume concentrations were prepared with the addition of surfactant by using the two-step method. The tests were conducted under the turbulent flow in the Dean number range of 2200 < De < 4200. The experiments were conducted with experimental Nusselt number is 28%, 52% and 68% higher than water for the nanofluids volume concentration of 0.1%, 0.3% and 0.5% respectively. It is found that the pressure drop of 0.1%, 0.3% and 0.5% nanofluids are found to be 16%, 30% and 42% respectively higher than water. It is studied that the prepared MWCNT/water nanofluids show good stability even after 45 days of preparation and there is no considerable deposit of nanotubes on the tube inner wall. It is also studied that there is no immediate risk of handling MWCNT and studied that there is no significant erosion of coiled tube inner wall surface even after several test runs. Therefore the MWCNT/water nanofluids are the alternate heat transfer fluids for traditional fluids in the cone helically coiled tube heat exchanger to improve the heat transfer with considerable pressure drop.
format Online
Article
Text
id pubmed-6536441
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-65364412019-05-30 Experimental investigation on convective heat transfer and pressure drop of cone helically coiled tube heat exchanger using carbon nanotubes/water nanofluids Palanisamy, K. Mukesh Kumar, P.C. Heliyon Article This study investigates the heat transfer and the pressure drop of cone helically coiled tube heat exchanger using (Multi wall carbon nano tube) MWCNT/water nanofluids. The MWCNT/water nanofluids at 0.1%, 0.3%, and 0.5% particle volume concentrations were prepared with the addition of surfactant by using the two-step method. The tests were conducted under the turbulent flow in the Dean number range of 2200 < De < 4200. The experiments were conducted with experimental Nusselt number is 28%, 52% and 68% higher than water for the nanofluids volume concentration of 0.1%, 0.3% and 0.5% respectively. It is found that the pressure drop of 0.1%, 0.3% and 0.5% nanofluids are found to be 16%, 30% and 42% respectively higher than water. It is studied that the prepared MWCNT/water nanofluids show good stability even after 45 days of preparation and there is no considerable deposit of nanotubes on the tube inner wall. It is also studied that there is no immediate risk of handling MWCNT and studied that there is no significant erosion of coiled tube inner wall surface even after several test runs. Therefore the MWCNT/water nanofluids are the alternate heat transfer fluids for traditional fluids in the cone helically coiled tube heat exchanger to improve the heat transfer with considerable pressure drop. Elsevier 2019-05-24 /pmc/articles/PMC6536441/ /pubmed/31193520 http://dx.doi.org/10.1016/j.heliyon.2019.e01705 Text en © 2019 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Palanisamy, K.
Mukesh Kumar, P.C.
Experimental investigation on convective heat transfer and pressure drop of cone helically coiled tube heat exchanger using carbon nanotubes/water nanofluids
title Experimental investigation on convective heat transfer and pressure drop of cone helically coiled tube heat exchanger using carbon nanotubes/water nanofluids
title_full Experimental investigation on convective heat transfer and pressure drop of cone helically coiled tube heat exchanger using carbon nanotubes/water nanofluids
title_fullStr Experimental investigation on convective heat transfer and pressure drop of cone helically coiled tube heat exchanger using carbon nanotubes/water nanofluids
title_full_unstemmed Experimental investigation on convective heat transfer and pressure drop of cone helically coiled tube heat exchanger using carbon nanotubes/water nanofluids
title_short Experimental investigation on convective heat transfer and pressure drop of cone helically coiled tube heat exchanger using carbon nanotubes/water nanofluids
title_sort experimental investigation on convective heat transfer and pressure drop of cone helically coiled tube heat exchanger using carbon nanotubes/water nanofluids
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6536441/
https://www.ncbi.nlm.nih.gov/pubmed/31193520
http://dx.doi.org/10.1016/j.heliyon.2019.e01705
work_keys_str_mv AT palanisamyk experimentalinvestigationonconvectiveheattransferandpressuredropofconehelicallycoiledtubeheatexchangerusingcarbonnanotubeswaternanofluids
AT mukeshkumarpc experimentalinvestigationonconvectiveheattransferandpressuredropofconehelicallycoiledtubeheatexchangerusingcarbonnanotubeswaternanofluids